Back to Authors

Díaz, Orlando

https://orcid.org/0000-0002-1131-3219

Mayo Clinic

Houston Methodist

Citations 3

Early postmarket results with PulseRider for treatment of wide-necked intracranial aneurysms: a multicenter experience
Srinivasan, Visish M. , Spiotta, Alejandro M , Hendricks, Benjamin K , Ducruet, Andrew F. , Albuquerque, Felipe C. , Puri, Ajit S , Cooke, Daniel L. , Ogilvy, Christopher S. , Enríquez-Marulanda, Alejandro , Rai, Ansaar , Boo, SoHyun , Carlson, Andrew P. , Crowley, R. Webster , Rangel-Castilla, Leonardo , Díaz, Orlando , Bohnstedt, Bradley N. , O’Connor, Kyle P. , Burkhardt, Jan‐Karl , Johnson, Jeremiah N., Chen, Stephen , Kan, Peter , Ogilvy, Christopher S , Srivatsan, Aditya , Amans, Matthew R. , Hetts, Steven W. , Thomas, Ajith J , Rangel-Castilla, Leonardo , Lanzino, Giuseppe , Chen, Peng R

Journal of Neurosurgery | December 13, 2019 | Volume: 133 | Issue: 6 | Pages: 1756-1765

10.3171/2019.5.jns19313 Get It

OBJECTIVE Traditionally, stent-assisted coiling and balloon remodeling have been the primary endovascular treatments for wide-necked intracranial aneurysms with complex morphologies. PulseRider is an aneurysm neck reconstruction device that provides parent vessel protection for aneurysm coiling. The objective of this study was to report early postmarket results with the PulseRider device. METHODS This study was a prospective registry of patients treated with PulseRider at 13 American neurointerventional centers following FDA approval of this device. Data collected included clinical presentation, aneurysm characteristics, treatment details, and perioperative events. Follow-up data included degree of aneurysm occlusion and delayed (> 30 days after the procedure) complications. RESULTS A total of 54 aneurysms were treated, with the same number of PulseRider devices, across 13 centers. Fourteen cases were in off-label locations (7 anterior communicating artery, 6 middle cerebral artery, and 1 A 1 segment anterior cerebral artery aneurysms). The average dome/neck ratio was 1.2. Technical success was achieved in 52 cases (96.2%). Major complications included the following: 3 procedure-related posterior cerebral artery strokes, a device-related intraoperative aneurysm rupture, and a delayed device thrombosis. Immediately postoperative Raymond-Roy occlusion classification (RROC) class 1 was achieved in 21 cases (40.3%), class 2 in 15 (28.8%), and class 3 in 16 cases (30.7%). Additional devices were used in 3 aneurysms. For those patients with 3- or 6-month angiographic follow-up (28 patients), 18 aneurysms (64.2%) were RROC class 1 and 8 (28.5%) were RROC class 2. CONCLUSIONS PulseRider is being used in both on- and off-label cases following FDA approval. The clinical and radiographic outcomes are comparable in real-world experience to the outcomes observed in earlier studies. Further experience is needed with the device to determine its role in the neurointerventionalist’s armamentarium, especially with regard to its off-label use.
Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results
Kallmes, David F. , Nelson, Peter Kim , Siddiqui, Adnan H. , Szikora, István , Zaidat, Osama O. , Colby, Geoffrey P. , Schirmer, Clemens M. , Hellinger, Frank R, Given, Curtis A., Tóth, Gábor , Priest, Ryan , Kan, Peter , Frei, Don , Aagaard‐Kienitz, Beverly , Díaz, Orlando , Malek, Adel M. , Cawley, C. Michael , Puri, Ajit S , Zaidat, Osama O , Colby, Geoffrey P , Mokin, Maxim , Taussky, Philipp , Toth, Gabor , Fraser, Justin F , Fiorella, David , Siddiqui, Adnan H , Szikora, Istvan , Schirmer, Clemens M , Hanel, Ricardó A. , Lopes, Demetrius K. , Jabbour, Pascal , Mendes Pereira, Vitor , Bettegowda, Chetan , Krings, Timo , Chen, Michael , Fiorella, David

Journal of NeuroInterventional Surgery | July 15, 2019 | Volume: 12 | Issue: 1 | Pages: 62-66

10.1136/neurintsurg-2019-015091 Get It

Background Preliminary clinical studies on the safety and efficacy of the pipeline embolization device (PED) for the treatment of small/medium aneurysms have demonstrated high occlusion rates with low complications. Objective To evaluate the safety and effectiveness of the PED for treatment of wide necked small and medium intracranial aneurysms. Methods PREMIER is a prospective, multicenter, single arm trial. Patients were treated with the PED for unruptured wide necked aneurysms, measuring ≤12 mm along the internal carotid artery or vertebral artery, between July 2014 and November 2015. At 1 year post-procedure, the primary effectiveness endpoint was complete occlusion (Raymond grade 1) without major parent vessel stenosis (≤50%) or retreatment, and the primary safety endpoint was major stroke in the territory supplied by the treated artery or neurologic death. Results A total of 141 patients were treated with PEDs (mean age 54.6±11.3 years, 87.9% (124/141) women). Mean aneurysm size was 5.0±1.92 mm, and 84.4% (119/141) measured <7 mm. PED placement was successful in 99.3% (140/141) of patients. Mean number of PEDs implanted per patient was 1.1±0.26; a single PED was used in 92.9% (131/141) of patients. At 1 year, 97.9% (138/141) of patients underwent follow-up angiography with 76.8% (106/138) of patients having met the study’s primary effectiveness endpoint. The combined major morbidity and mortality rate was 2.1% (3/140). Conclusions Treatment of wide necked small/medium aneurysms with the PED results in high rates of complete occlusion without significant parent vessel stenosis and low rates of permanent neurologic complications. Trial registration NCT02186561 .
GEL THE NEC: a prospective registry evaluating the safety, ease of use, and efficacy of the HydroSoft coil as a finishing device
Brinjikji, Waleed , Amar, Arun Paul , Almandoz, Josser E Delgado , Díaz, Orlando , Jabbour, Pascal , Kelly, Michael , Layton, Kennith D, Miller, Jeffrey W. , Levy, Elad, Moran, Christopher J. , Woo, Henry H. , Sellar, Robin, Ho, Brian , Evans, Avery J. , Kallmes, David F. , Suh, Dae C , Jabbour, Pascal , Hanel, Ricardó A. , Hui, Ferdinand , Levy, E, Ho, Brian, Miller, Jeffrey

Journal of NeuroInterventional Surgery | January 30, 2017 | Volume: 10 | Issue: 1 | Pages: 83-87

10.1136/neurintsurg-2016-012915 Get It

Background and purpose The HydroSoft coil was developed as a finishing coil, ideally to be placed along the aneurysm neck to enhance intracranial aneurysm healing. The GEL THE NEC (Gaining Efficacy Long Term: Hydrosoft, an Emerging, New, Embolic Coil) multicenter registry was developed to assess the safety and efficacy of HydroSoft coils in treating intracranial aneurysms. We report angiographic and clinical results of this prospective registry. Materials and methods GEL THE NEC was performed at 27 centers in five countries. Patients aged 21–90 years with a ruptured or unruptured aneurysm 3–15 mm in size were eligible for enrollment. The following variables were obtained: demographics/comorbidities, aneurysm geometry, adjunctive devices used, proportion of patients in whom HydroSoft coils were successfully placed, and long-term angiographic outcomes (graded by an independent core laboratory using the Modified Raymond Scale), and procedure-related adverse events. Predictors of good angiographic outcome were studied using χ2 and t-tests. Results A total of 599 patients with 599 aneurysms were included in this study. HydroSoft coils were successfully deployed in 577 (96.4%) patients. Procedure-related major morbidity and mortality were 0.5% (3/599) and 1.3% (8/599), respectively. The most common perioperative complications were iatrogenic vasospasm (30/599, 5.0%), thromboemboli (27/599, 4.5%), and aneurysm perforation (16/599, 2.7%). At last angiographic follow-up (mean 9.0±6.3 months), the complete occlusion rate was 63.2% (280/442) and near complete occlusion rate was 25.2% (107/442). The core laboratory read recanalization rate was 10.8% (46/425) and the retreatment rate was 3.4% (20/599). Conclusions Endovascular treatment of intracranial aneurysms with HydroSoft coils resulted in complete/near complete occlusion rates of 88% and a major complication rate of 1.8%. Trial registration number NCT01000675.