OBJECTIVE The objective was to evaluate the trajectories of hematoma resolution and functional improvement after middle meningeal artery embolization (MMAE) for chronic subdural hematoma (cSDH), model the temporal pattern of cSDH resolution, and identify factors associated with favorable outcomes. METHODS This real-world multicenter retrospective study included cSDH patients treated with MMAE at 24 centers between 2019 and 2024. Hematoma thickness was measured at baseline and at follow-up intervals (1–4 weeks, 1–3 months, 3–6 months, 6–12 months, and > 12 months after embolization). Resolution patterns were modeled using exponential decay functions. Modified Rankin Scale (mRS) scores assessed functional outcomes. Good functional outcome was defined as mRS score ≤ 2. Resolution patterns were modeled using exponential decay functions to estimate time to 50% and 80% reduction. Patients were categorized as complete resolution (≥ 99%) or by quartile of the remaining distribution (substantial [73%–98%], moderate [53%–73%], partial [27%–53%], minimal [< 27%]). The primary outcome was good functional status (mRS score ≤ 2). RESULTS The authors analyzed a total of 1781 patients with 2295 cSDHs who underwent MMAE. The mean ± SD age was 72.8 ± 12.4 years and 68.1% of patients were male. The initial mean hematoma thickness was 15.31 ± 6.53 mm, decreasing to 5.24 ± 5.91 mm at final follow-up (mean reduction 64.3% ± 42.1%). Resolution followed an exponential decay pattern, with an estimated time to 50% reduction of 1.8 months and to 80% reduction of 8.9 months. Complete resolution occurred in 1031 of 2224 patients (46.4%) with complete follow-up. The median (IQR) mRS score improved from 1 (0–3) at baseline to 0 (0–2) at > 12 months. Good functional outcomes were more common in patients with complete versus minimal resolution (68.9% vs 35.0%, p < 0.001). Achieving ≥ 73% resolution within 90 days was associated with better outcomes (good outcome in 76.9% of those with ≥ 73% resolution vs 67.3% in those without, p < 0.001). Neurological deterioration was the strongest predictor of lack of good outcome (23.7% in patients with neurological deterioration vs 82.4% without, p < 0.001). CONCLUSIONS After MMAE for cSDH, reduction in hematoma thickness follows a predictable exponential decay pattern. Greater extent (≥ 80%) and faster timing (within 90 days) of resolution are valuable prognostic indicators. Functional outcomes improve progressively through 6–12 months after the procedure. The relationship between resolution extent and functional outcomes provides quantitative benchmarks for evaluating treatment response.
Woven EndoBridge Device for Ruptured vs. Unruptured Aneurysms: Insights from the WorldWideWEB Study
Abstract Purpose Although the Woven EndoBridge (WEB) device is increasingly used for the treatment of wide-neck intracranial aneurysms, including in the acute rupture setting, comparative evidence assessing the impact of rupture status remains limited. This study compared angiographic, safety, and clinical outcomes between ruptured and unruptured intracranial aneurysms treated with WEB. Methods We conducted a retrospective analysis of prospectively collected data from the multicenter cohort registry WorldWideWEB, including consecutive adult patients with intracranial aneurysms treated with the WEB. Patients were stratified into groups of ruptured and unruptured aneurysms. Propensity score matching was used to balance baseline characteristics between both groups. Retreatment rate was the primary outcome. Secondary outcomes included mRS, safety events (thromboembolic complications) and angiographic outcomes (periprocedurally and last follow-up). Results Among 1,220 patients, 342 (28.0%) presented with ruptured aneurysms. There was no significant difference in the rate of thromboembolic complications between groups (11.8% vs 5.9%, p = 0.056). At follow-up, adequate occlusion was lower (82.2% vs 93.3%, p < 0.002) and functional outcomes were worse (mRS ≥2 in 34.1% vs 21.9%, p = 0.012) among patients with ruptured aneurysms. Periprocedural adequate occlusion (53.3% vs 53.8%, p>0.9) and retreatment rates (11.8% vs 7.1%, p = 0.14) did not differ between groups after matching. Conclusion Ruptured aneurysms demonstrated expected inferior follow-up functional and angiographic outcomes when compared with unruptured aneurysms, but no difference in retreatment rate and procedural safety. These findings support WEB as a safe and effective treatment option for appropriately selected ruptured intracranial aneurysms in routine clinical practice.
Associated Risks to the Treatment of Unruptured Intracranial Aneurysms (MARTA) Score: Development and External Validation
BACKGROUND AND OBJECTIVES: Unruptured intracranial aneurysms (UIAs) are increasingly detected and require careful management to prevent rupture. No externally validated score currently predicts procedural risk to guide treatment decisions. We developed and validated 2 predictive scores for complications after endovascular treatment (EVT) or neurosurgical treatment (NT) of UIA using routinely collected clinical and aneurysmal features. METHODS: We conducted a multicenter retrospective study including patients with UIA treated with EVT or NT across 15 neurovascular centers (2014-2024). Predictive models were built using multivariable logistic regression, with variables derived from Delphi consensus. The primary outcome was a composite safety end point: new neurological deficits, modified Rankin Scale (mRS) worsening (≥1 point or mRS 2-5 within 30 days), or procedural death. Internal validation used bootstrapping, and external validation was performed temporally and institutionally. Model performance was assessed using area under the receiver operating characteristic curve (AUROC) and calibration. Final scores, named Morbidity and Mortality Associated Risk in the Treatment of UIAs (MARTA)-EVT and MARTA-NT, were compared with existing models identified through systematic review. RESULTS: Among 2647 patients (1907 EVT and 740 NT), procedural complications occurred in 6.3% (EVT) and 12.8% (NT). Independent predictors included age, baseline mRS, aneurysm location, size, morphology, and procedural factors. MARTA-EVT (AUROC = 0.68, 95% CI = 0.57-0.78) and MARTA-NT (AUROC = 0.65, 95% CI = 0.54-0.77) showed moderate discrimination and good calibration. MARTA-EVT outperformed existing models; MARTA-NT performed similarly to SAFETEA. Predictive models are available open-source: https://martascoreapp.shinyapps.io/martascoreapp/. CONCLUSION: MARTA-EVT and MARTA-NT are validated tools for predicting procedural risks in UIA treatment and may support patient counseling and clinical decision making.
Predictive modeling of long-term improvement in occlusion outcomes following Woven EndoBridge treatment of cerebral aneurysms: A machine learning approach
Background The Woven EndoBridge (WEB) device represents an innovative solution for cerebral aneurysm occlusion, particularly for challenging wide-neck bifurcation aneurysms. However, factors affecting sustained occlusion remain poorly understood. We utilized machine learning to attempt to identify predictors of favorable long-term outcomes following WEB treatment. Methods In this multicenter retrospective study, we collected patient demographics, aneurysm characteristics, procedural details, and clinical outcomes. The primary endpoint was improvement in occlusion status, defined as maintained Raymond-Roy Occlusion Classification (RROC) grade 1, or improvement from grade 2 to 1, or from grade 3 to either 2 or 1 on final angiographic follow up. The dataset was split into training (75%) and validation (25%) sets. The CatBoost algorithm was selected based on performance metrics, with Shapley Additive exPlanations (SHAP) values calculated to determine feature importance. Furthermore, a multivariable binomial logistic regression model was performed to validate machine learning findings. Results Among 720 aneurysms from 36 hospitals, 84% showed improvement in occlusion at follow up. Both machine learning and multivariable logistic regression identified aneurysm height as the most consistent correlate of nonimprovement (odds ratio (OR) 0.90 per mm, p = 0.022). In the CatBoost model, the highest-ranking features by SHAP included aneurysm height, patient age, treatment acuity, ACom location, WEB-SLS device, bifurcation anatomy, aneurysm multiplicity, baseline modified Rankin Scale, access route, and partial thrombosis. Conclusions Machine-learning and regression analyses identified consistent predictors of occlusion improvement after WEB treatment, with aneurysm height most strongly linked to nonimprovement. These insights may guide patient selection and follow up. Findings require cautious interpretation and external validation in larger cohorts.
Macrowire-only direct aspiration first-pass technique for endovascular mechanical thrombectomy: Multicenter technical series using the 0.035″ aristotle Colossus wire
Background Larger “macrowires” may facilitate microcatheter-free delivery of large-bore aspiration catheters (ACs) for intracranial endovascular mechanical thrombectomy. We examined the safety and efficacy of the Aristotle Colossus Guidewire for this use. Methods In this retrospective analysis of prospective data from 12 institutions, we identified anterior circulation endovascular mechanical thrombectomy cases involving the Aristotle Colossus guidewire over a 12-month period. The primary efficacy endpoint was successful delivery of the AC to the site without the use of adjunct devices. Multivariable logistic regression was performed with clinically relevant covariables. Results In 122 patients (median age 74 years (interquartile range (IQR) 63–82)), most intracranial occlusions were in the M1 segment of the middle cerebral artery (95/122, 78.0%). The primary endpoint of microcatheter-free AC delivery was met in 87.7% (107/122) of patients; 93/122 (76.2%) patients underwent microcatheter-free delivery with successful reperfusion via contact aspiration (modified thrombolysis in cerebral infarction grade ≥ 2B). The median number of passes was 1 (IQR 1–2). Multivariable regression demonstrated that severe internal carotid artery tortuosity or cervical loop presence (odds ratio (OR): 0.09, 95% confidence interval (CI): 0.01–0.54, p = 0.01) and presence of intracranial atherosclerotic disease (OR: 0.15, 95% CI: 0.03–0.83, p = 0.03) were significantly associated with lower odds of successful AC delivery over the guidewire. Intraprocedural vasospasm occurred in 4.9% (6/122) of cases; there were no reports of vessel dissection or perforation. Conclusions We demonstrate the favorable performance of the Aristotle Colossus guidewire for anterior circulation ischemic stroke intervention. The macrowire appears to safely facilitate navigation of the neurovasculature by large-bore ACs without the need for microcatheter and/or stentriever.
Higher risk of recurrence in partially thrombosed cerebral aneurysms post-WEB (Woven EndoBridge) device treatment: insights from the WorldWideWEB Consortium registry
Background The Woven EndoBridge (WEB) device is a prevalent treatment for intracranial aneurysms. While many studies have assessed the obliteration rate post-WEB embolization, few have focused on long-term outcomes in partially thrombosed aneurysms. Objective To assess whether partially thrombosed aneurysms are at higher risk of recurrence or retreatment following WEB embolization compared with non-thrombosed aneurysms. Methods We evaluated data from 22 academic institutions, focusing on previously untreated cerebral aneurysms treated with the WEB device. Logistic regression was utilized to analyze factors predicting long-term aneurysm obliteration and retreatment necessity. Results Among 1303 patients, 26 presented with a partially thrombosed aneurysm. In the partially thrombosed group, the mean aneurysm maximal diameter was 10.7±4 mm with a neck ratio of 1.99±1.19 mm, larger than in the control group where the mean aneurysm maximal diameter was 6.81±2.37 mm with a neck ratio of 1.64±0.51 mm (P<0.001 for both maximal diameter and neck ratio). At the final follow-up, partially thrombosed aneurysms treated by the WEB device had a 38.5% retreatment rate, compared with 7.0% for non-thrombosed aneurysms (P<0.001). Among partially thrombosed aneurysms, the Raymond-Roy type IIIa/b occlusion rate was higher (38.5% vs 9.9%, P<0.001). On multivariate analysis, partially thrombosed aneurysms compared with non-thrombosed aneurysms had an increased rate of retreatment (OR 3.64, 95% CI 1.28 to 10.1). Conclusion Partially thrombosed aneurysms are associated with a poorer occlusion rate and a higher rate of retreatment following WEB embolization. For partially thrombosed aneurysms, the WEB device appears suboptimal as a first-line treatment, and therefore alternative techniques should be prioritized.
Multicenter analysis of flow diversion for recurrent/persistent intracranial aneurysms after stent-assisted coiling
Background Flow-diverter stents (FDS) have become the standard of care for a wide range of intracranial aneurysms, but their efficacy/safety in the context of recurrent/recanalized aneurysms following stent-assisted coiling (SAC) is not well established. We evaluate the outcomes of FDS retreatment in a large multicenter cohort. Methods We retrospectively analyzed data from 118 patients across 22 institutions who underwent FDS retreatment for recurrent/persistent aneurysms after SAC (2008–22). The primary outcome was angiographic occlusion status at last follow-up, categorized as complete (100%), near-complete (90–99%), or incomplete (<90%) occlusion. Secondary outcomes included procedural complications and clinical outcomes measured by the modified Rankin Scale (mRS). Results A total of 118 patients (median age 57, 74.6% female) with median follow-up of 15.3 months were identified. Complete occlusion was achieved in 62.5% and near-complete occlusion in 25%. FDS deployment within the pre-existing stent was successful in 98.3% of cases. Major complications occurred in 3.4% of cases, including postoperative aneurysmal rupture with resultant mortality (1.6%) and thromboembolic events with long-term disability (1.6%). Favorable clinical outcomes (mRS 0–2) were observed in 95.1% of patients. Wider aneurysm neck diameter was a significant predictor of incomplete occlusion (adjusted OR (aOR) 1.23 per mm, P=0.044), with male sex trending towards association with non-occlusion (aOR 3.2, P=0.07), while baseline hypertension was associated with complete occlusion (aOR 0.32, P=0.048). Conclusions FDS treatment for recurrent/residual aneurysms after SAC represents a viable treatment option for these challenging cases with acceptable safety and reasonable occlusion rates, although lower than de novo FDS occlusion rates.
Impact of smoking on recurrence rates among wide-neck intracranial aneurysms treated with Woven EndoBridge: a multicenter retrospective study
OBJECTIVE Tobacco smoking is among the factors known to significantly augment the risk of untreated intracranial aneurysm (IA) growth and rupture. Smoking appears to have a variable effect on different endovascular treatment modalities. The impact of smoking on the safety, efficacy, and outcomes of Woven EndoBridge (WEB) device use for wide-neck IAs has not been evaluated. This study aimed to investigate the outcomes of WEB devices by smoking status. METHODS A retrospective multicenter analysis was conducted on the data of patients from 36 sites worldwide treated with the WEB device for intracranial saccular aneurysms. Patients were stratified based on smoking status (current, former, and never smokers). The Student t-test and chi-square test were performed for continuous and categorical variables, respectively. Multivariable logistic regression was used to adjust for confounders. RESULTS Of 1376 patients with available smoking status, 504 were current smokers, 358 were former smokers, and 514 were never smokers. Upon adjusting for significant confounders, no association was found between smoking and recurrence outcomes (OR 1.39, 95% CI 0.69–2.80; p = 0.36), thromboembolic and hemorrhagic complications, and mortality among IAs treated with the WEB device. There was no statistically significant difference in outcomes between former and never smokers (OR 1.23, 95% CI 0.70–2.18; p = 0.46). The location of aneurysms differed between smoking groups, with former smokers having more anterior circulation aneurysms compared with current and never smokers (99.0% vs 96.9% vs 95.3%; p = 0.01). In terms of clinical symptoms, headache and dizziness were more common in the never smokers compared with current and former smokers (13.9% vs 8.9% vs 7.7%, p = 0.01). CONCLUSIONS This large-scale study suggests no significant correlation between smoking and the recurrence of IAs treated with the WEB device. Biological studies are warranted to better understand the biological impact of smoking on the growth and rupture of treated IAs.
Abstract 149: Tenecteplase versus Alteplase before Mechanical Thrombectomy in Acute Ischemic Stroke: A Systematic Review and Meta‐analysis
OBJECTIVE The Woven EndoBridge (WEB) device was approved to treat wide-necked bifurcation aneurysms. The device is designed as an intrasaccular flow disruptor covering aneurysm widths up to 10 mm. Although prior studies combined all aneurysm sizes, it is known that aneurysms behave differently in response to endovascular treatment based on their size. Therefore, the authors’ objective was to identify ideal middle cerebral artery (MCA) aneurysm width and neck sizes most suitable for WEB treatment. METHODS The WorldWideWEB consortium is a large multicenter retrospective database that analyzes intracranial aneurysms treated with the WEB device. In this study, all unruptured MCA bifurcation aneurysms with available measurements were included. Cutoff values based on aneurysm width and neck in relation to aneurysm occlusion status were measured using the receiver operating characteristic (ROC) curve. Propensity score matching (PSM) was then used to compare treatment outcomes between aneurysms smaller and larger than the cutoff value for both width and neck size. RESULTS The ideal cutoff values for MCA bifurcation aneurysm width and neck were 6.1 mm and 4.6 mm, respectively. On PSM, 87 matched pairs were compared based on width size (≤ 6.1 mm and > 6.1 mm), and 77 matched pairs were compared based on neck size (≤ 4.6 mm and > 4.6 mm). There was a significant difference in adequate aneurysm occlusion between aneurysms smaller and larger than those cutoff values for both widths (93% vs 76%, p = 0.0017) and neck sizes (90% vs 70%, p = 0.0026). The retreatment rate was also significantly higher for larger aneurysms in both parameters. CONCLUSIONS This study shows that MCA bifurcation aneurysms ≤ 6.1 mm in width and ≤ 4.6 mm in neck size are significantly better candidates for WEB treatment, leading to improved occlusion status and reduced retreatment rate, which are important considerations when using WEB devices.