BACKGROUND AND OBJECTIVES: Unruptured intracranial aneurysms (UIAs) are increasingly detected and require careful management to prevent rupture. No externally validated score currently predicts procedural risk to guide treatment decisions. We developed and validated 2 predictive scores for complications after endovascular treatment (EVT) or neurosurgical treatment (NT) of UIA using routinely collected clinical and aneurysmal features. METHODS: We conducted a multicenter retrospective study including patients with UIA treated with EVT or NT across 15 neurovascular centers (2014-2024). Predictive models were built using multivariable logistic regression, with variables derived from Delphi consensus. The primary outcome was a composite safety end point: new neurological deficits, modified Rankin Scale (mRS) worsening (≥1 point or mRS 2-5 within 30 days), or procedural death. Internal validation used bootstrapping, and external validation was performed temporally and institutionally. Model performance was assessed using area under the receiver operating characteristic curve (AUROC) and calibration. Final scores, named Morbidity and Mortality Associated Risk in the Treatment of UIAs (MARTA)-EVT and MARTA-NT, were compared with existing models identified through systematic review. RESULTS: Among 2647 patients (1907 EVT and 740 NT), procedural complications occurred in 6.3% (EVT) and 12.8% (NT). Independent predictors included age, baseline mRS, aneurysm location, size, morphology, and procedural factors. MARTA-EVT (AUROC = 0.68, 95% CI = 0.57-0.78) and MARTA-NT (AUROC = 0.65, 95% CI = 0.54-0.77) showed moderate discrimination and good calibration. MARTA-EVT outperformed existing models; MARTA-NT performed similarly to SAFETEA. Predictive models are available open-source: https://martascoreapp.shinyapps.io/martascoreapp/. CONCLUSION: MARTA-EVT and MARTA-NT are validated tools for predicting procedural risks in UIA treatment and may support patient counseling and clinical decision making.
Trackability of distal access catheters: an in vitro quantitative evaluation of navigation strategies
Background In mechanical thrombectomy (MT), distal access catheters (DACs) are tracked through the vascular anatomy to reach the occlusion site. The inability of DACs to reach the occlusion site has been reported as a predictor of unsuccessful recanalization. This study aims to provide insight into how to navigate devices through the vascular anatomy with minimal track forces, since higher forces may imply more risk of vascular injuries. Methods We designed an experimental setup to monitor DAC track forces when navigating through an in vitro anatomical model. Experiments were recorded to study mechanical behaviors such as tension buildup against vessel walls, DAC buckling, and abrupt advancements. A multiple regression analysis was performed to predict track forces from the catheters’ design specifications. Results DACs were successfully delivered to the target M1 in 60 of 63 in vitro experiments (95.2%). Compared to navigation with unsupported DAC, the concomitant coaxial use of a microcatheter/microguidewire and microcatheter/stent retriever anchoring significantly reduced the track forces by about 63% and 77%, respectively (p<0.01). The presence of the braid pattern in the reinforcement significantly reduced the track forces regardless of the technique used (p<0.05). Combined coil and braid reinforcement configuration, as compared with coil alone, and a thinner distal wall were predictors of lower track force when navigating with unsupported DAC. Conclusions The use of microcatheter and stent retriever facilitate smooth navigation of DACs through the vascular tortuosity to reach the occlusion site, which in turn improves the reliability of tracking when positioning the DAC closer to the thrombus interface.