Purpose Optimizing the preparation of a 10 ml syringe for manual injection of contrast media can help operators obtain easier and faster injections. This study aims to compare the flow rates of different contrast media injection methods. Methods Different contrast media solutions were compared: 100% contrast (10 ml contrast), mixed contrast solution (8:2 contrast/saline), and layered contrast below saline (“Parfait”) in different volumes. Contrast media were injected at room temperature (20°C) and after heating (37°C). Four operators injected 10 ml syringes filled with different mediums through 5-French angiographic catheters. The average flow rate was used to compare different contrast injection mediums. The Kruskal-Wallis test with post-hoc pairwise comparisons using Bonferroni correction or Mann-Whitney U-tests were employed depending on the type of comparison. Results Compared to the 100% contrast solution, every Parfait media and mixed contrast solution demonstrated significantly higher flow rates (p < 0.001). The 5 ml saline Parfait had the highest flow rate among the Parfait solutions. The 5 ml saline Parfait and the mixed solution had comparable flow rates (p = 0.237). Higher flow rates were observed upon heating both 100% contrast (p < 0.001) and mixed contrast solutions (p < 0.001) in comparison to their flow rates at room temperature. Conclusion This study demonstrates the capability of the Parfait and mixed contrast injections to achieve higher flow rates than the 100% contrast solutions. Heating the contrast media to 37°C also proves to be a viable strategy for further enhancing the flow rates for 100% and mixed contrast solutions.
In vitro evaluation of flow diverter performance using a human fibrinogen–based flow model
OBJECTIVE Fibrin deposition represents a key step in aneurysm occlusion, promoting endothelization of implants and connective tissue organization as part of the aneurysm-healing mechanism. In this study, the authors introduce a novel in vitro testing platform for flow diverters based on human fibrinogen. METHODS A flow diverter was deployed in 4 different glass models. The glass models had the same internal parent artery (4 mm) and aneurysm (8 mm) diameters with varying parent artery angulations (paraophthalmic, sidewall, bifurcation, and slightly curved models). The neck size and area were 4 mm and 25 mm 2 , respectively. Human fibrinogen (330 mg/dl) was circulated within the glass models at varying flow rates (0, 3, 4, and 5 ml/sec) with or without heparin, calcium chloride, and thrombin for as long as 6 hours or until complete fibrin coverage of the flow diverter’s neck was achieved. Aneurysm neck coverage was defined as macroscopic fibrin deposition occluding the flow diverters’ pores. Flow characteristics after flow diverter deployment were assessed with computational fluid dynamics analysis. The effects of flow rates, heparin, calcium chloride, and thrombin on fibrin deposition rates were tested using 1-way ANOVA and the Tukey test. RESULTS A total of 84 replicates were performed. Human fibrin did not accumulate on the flow diverter stents under static conditions. The fibrin deposition rate on the aneurysm neck was significantly greater with the 5 ml/sec flow rate as compared to 3 ml/sec for all models. The paraophthalmic model had the highest inflow velocity of 48.7 cm/sec. The bifurcation model had the highest maximum shear stress (SS) and maximum normalized shear stress values at the device cells at 843.3 dyne/cm 2 and 35.1 SS/SS inflow , respectively. The fibrin deposition rates of the paraophthalmic and bifurcation models were significantly higher than those of sidewall and slightly curved models for all additive or flow rate comparisons (p = 0.001 for all comparisons). The incorporation of thrombin significantly increased the fibrin deposition rates across all models (p = 0.001 for all models). CONCLUSIONS Rates of fibrin deposition varied widely across different configurations and additive conditions in this novel in vitro model system. Fibrin accumulation started at the aneurysm inflow zone where flow velocity and shear stress were the highest. The primary factors influencing fibrin deposition included flow velocities, shear stress, and the addition of thrombin at a physiological concentration. Further research is needed to test the clinical utility of fibrinogen-based models for patient-specific aneurysms.
Plunge with caution: safeguarding patients in mechanical thrombectomy
Abstract 153: Pre‐procedural 3D visualization of deep‐learning vascular segmentation enhances identification of difficult femoral access in thrombectomy
Introduction Difficult or impossible femoral access remains a significant burden for mechanical thrombectomy (MT) in stroke, affecting between 4.4% (impossible) to ∼10% of cases (time to first angiography [T1A] > 30 min) [1]. Visualization of CT angiography (CTA) or MR angiography are the only available diagnostic tools for neurointerventionalists (NIs) to qualitatively assess catheterization difficulty ahead of intervention. Visualization of 3D segmentation of the head‐and‐neck arteries from CTA may provide enhanced spatial information for catheter access difficulty assessment to the occlusion site, as well as large vessel occlusion (LVO) localization or carotid stenosis detection. Methods Three observers (2 expert NIs and 1 medical image engineer) assessed a sample of patients with anterior circulation stroke rating LVO location, femoral access difficulty according to a Likert scale (0 to 5) and assessment of radial access compared to femoral (easier or not). Raters were asked to answer the same form for each case twice, once after visualizing only the CTA and again after visualizing a deep‐learning, automated 3D segmentation of the head‐and‐neck arteries from CTA [2]. Cases were randomly sampled and blind to raters for both assessments. Likert scale values were normalized and averaged across observers, and correlation to T1A was studied. LVO localization accuracy and time needed for the analysis was also assessed. Results The final sample included N = 117 cases, where 22.98% presented difficult or impossible access. LVO location prevalence was 13/15/45/27% for extracranial ICA (eICA)/TICA/M1/M2, and 49/51% for right/left. Averaged Likert values presented significant linear correlation for both segmentation and CTA visualization, but this was much stronger in the former (R: 0.58 vs 0.30, p<0.001). Three‐dimensional visualization of segmented vessels allowed for an enhanced detection of difficult or impossible femoral access (ROC‐AUC: 0.85 vs 0.66). LVO detection was also superior after segmentation visualization (mean accuracy across observers: 0.81 vs 0.72) and time needed for assessment was on average 2.3 times shorter (44 s vs 100 s). In difficult or impossible patients, radial access was considered easier in 74% (63‐89%) of cases when visualizing the segmentation compared to 42% (35‐48%) when inspecting the CTA. Conclusion Visualization of deep‐learning 3D arterial segmentation resulted in enhanced difficult or impossible femoral access for MT, LVO detection and faster analysis over traditional pre‐procedural CTA inspection. Adding this visualization to the current workflow could enhance difficult access detection ahead of intervention.
Comparative analysis of syringes versus pump devices in benchtop aspiration thrombectomy models: A systematic review and meta-analysis
Background Although direct contact aspiration has emerged as one of the leading techniques for mechanical thrombectomy (MT), there is still ongoing debate about the aspiration/suction pump devices that can optimize recanalization rates. To address this gap, we conducted a meta-analysis comparing the aspiration efficacy of 60 ml syringe and pump devices in benchtop MT models. Methods Systematic literature review was conducted using Medline, Embase, Web of Science, and Scopus in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Outcomes of interest included flow rate and vacuum pressure delivered by a 60 ml syringe and several aspiration pumps. We used a random effects model to calculate the mean difference (MD) with 95% confidence intervals (CIs) and a statistically significant difference was considered as a two-sided p -value of less than 0.05. Results We included six benchtop studies comparing 60 ml syringes and vacuum pumps. Our meta-analysis showed that there were no significant differences in vacuum pressure (MD:0.71inHg, 95% CI: [−0.81;2.23], p = 0.359) and flow rate (MD:0.27 mL/s, 95% CI: [−3,07; 3.61], p = 0.873) between 60 ml syringes and vacuum pumps groups. Conclusions Our study demonstrated comparable performance in terms of vacuum pressure and flow rates between a 60 ml syringe and a heterogeneous combination of commercially available aspiration pumps.
Catheter design primer for neurointerventionalists
Neurovascular catheter technology has rapidly evolved over the past decade. While performance characteristics are well known to the practitioner, the design features of these new-generation catheters and their implications on performance metrics remain a mystery to most clinicians due to the limited number of available resources. This knowledge gap hampers informed device choices and also limits collaboration between clinicians and engineers. To aid fellow neurointerventionalists, in this primer we have summarized the basic concepts of catheter design and construction.
Trackability of distal access catheters: an in vitro quantitative evaluation of navigation strategies
Background In mechanical thrombectomy (MT), distal access catheters (DACs) are tracked through the vascular anatomy to reach the occlusion site. The inability of DACs to reach the occlusion site has been reported as a predictor of unsuccessful recanalization. This study aims to provide insight into how to navigate devices through the vascular anatomy with minimal track forces, since higher forces may imply more risk of vascular injuries. Methods We designed an experimental setup to monitor DAC track forces when navigating through an in vitro anatomical model. Experiments were recorded to study mechanical behaviors such as tension buildup against vessel walls, DAC buckling, and abrupt advancements. A multiple regression analysis was performed to predict track forces from the catheters’ design specifications. Results DACs were successfully delivered to the target M1 in 60 of 63 in vitro experiments (95.2%). Compared to navigation with unsupported DAC, the concomitant coaxial use of a microcatheter/microguidewire and microcatheter/stent retriever anchoring significantly reduced the track forces by about 63% and 77%, respectively (p<0.01). The presence of the braid pattern in the reinforcement significantly reduced the track forces regardless of the technique used (p<0.05). Combined coil and braid reinforcement configuration, as compared with coil alone, and a thinner distal wall were predictors of lower track force when navigating with unsupported DAC. Conclusions The use of microcatheter and stent retriever facilitate smooth navigation of DACs through the vascular tortuosity to reach the occlusion site, which in turn improves the reliability of tracking when positioning the DAC closer to the thrombus interface.