Modeling Perforator Occlusion After Flow Diversion
Mut, Fernando , Bayraktar, Esref Alperen , Dai, Daying , Ognard, Julien , Cortese, Jonathan, Kallmes, David, Kadirvel, Ramanathan , Cebral, Juan R. , Marsh, Laurel , Mut, Fernando , Bayraktar, Esref Alperen , Dai, Daying , Ognard, Julien , Kadirvel, Ram , Cebral, Juan R , Marsh, Laurel , Cortese, Jonathan

International Journal for Numerical Methods in Biomedical Engineering | August 20, 2026 | Volume: 42 | Issue: 8 | Pages: No page available

10.1002/cnm.70207 Get It

ABSTRACT Endoluminal flow diverters are increasingly used to treat cerebral aneurysms. Despite good aneurysm occlusion efficacy, delayed ischemic complications due to side branch or perforator occlusion remain a serious concern. However, the mechanisms leading to side branch occlusion are poorly understood. To investigate these mechanisms, a combination of animal and computational models was utilized. Flow diverters were deployed in four rabbit superior mesenteric artery (SMA) and studied with computational fluid dynamics (CFD) and a previously developed fibrin dynamics model. Subject‐specific vascular models were reconstructed from 3D rotational angiography images and flow conditions were derived from Doppler ultrasound velocity measurements. Flow diverting devices were virtually deployed within the vascular models under guidance from angiography images. Coupled flow and fibrin production, transport, and adhesion simulations were carried out and the effects of fibrin accumulation at the origin of jailed side branches after flow diverter implantation were analyzed. The results of the computational models suggest significant fibrin accumulation across the struts of all flow diverting devices jailing side branches. Larger accumulation was observed at the more distal branches. However, minor flow alterations were produced which were not detectable in angiography sequences. These results were in agreement with experimental observations. On the other hand, fibrin accumulation alone did not explain complete side branch occlusions, which are likely the result of the interaction between initial fibrin accumulation and subsequent cell migration from the peripheral parent artery.
Venous Sinus Stenting for Pulsatile Tinnitus: A Systematic Review and Meta-Analysis
Khabir, Sevda Alipour , Ognard, Julien, Souza, Natália Vasconcellos de Oliveira , Heidtke, Owen, Lindell, Tor, Bayraktar, Esref, Bilgin, C, Ghozy, S, Kadirvel, R, Kallmes, David F., Brinjikji, Waleed , Alipour Khabir, Sevda , El Hajj, Gerard , de Oliveira Souza, Natália Vasconcellos , Ognard, Julien , Hajj, G El , Bayraktar, Esref Alperen , Ghozy, Sherief , Kadirvel, Ramanathan , Kallmes, David F.

Otology & Neurotology | July 21, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/mao.0000000000005016 Get It

Background: Pulsatile tinnitus (PT) is frequently caused by venous sinus stenosis and may be associated with idiopathic intracranial hypertension (IIH). Venous sinus stenting (VSS) directly addresses venous outflow obstruction and has emerged as a therapeutic option; however, outcome data remain heterogeneous. We performed an updated systematic review and meta-analysis to evaluate the efficacy and durability of VSS for PT and to compare outcomes between IIH-associated and isolated PT. Methods: MEDLINE, Scopus, and Web of Science were searched from inception through December 2025 following PRISMA guidelines. Clinical studies reporting PT outcomes after VSS were included. Random-effects meta-analyses of proportions were conducted to estimate pooled rates of overall improvement, complete resolution, and recurrence. Prespecified subgroup analyses compared IIH versus isolated PT. Results: Thirty-two studies comprising 850 patients were included (641 with IIH; 209 with isolated PT). Venous sinus stenosis accounted for 90.3% of treated etiologies. The pooled rate of overall PT improvement was 89.8% (95% CI, 85.5-92.9). Complete resolution occurred in 87.1% (95% CI, 82.5-90.6). Recurrence at last follow-up was 10.9% (95% CI, 8.3-14.2). Improvement and complete resolution rates did not differ significantly between IIH and isolated PT. Recurrence was higher in IIH (12.0%) than in isolated PT (5.7%), without reaching statistical significance. Conclusions: VSS is associated with high rates of PT improvement and complete resolution with low recurrence. Recurrence trends appear higher in IIH, suggesting underlying pathophysiology may influence durability.
Development of a novel elastase-induced saccular aneurysm model in rats suitable for testing endovascular devices: An experimental animal study
Ueki, Yasuhito , Bayraktar, Esref Alperen , Ognard, Julien, Hajj, G El , Ding, Yonghong , Dai, Daying , Rinaldo, Lorenzo , Kadirvel, Ramanathan , Kallmes, David F. , Bayraktar, Esref Alperen , El Hajj, Gerard , Ding, Yong-Hong , Kadirvel, Ram , Dai, Daying , Ognard, Julien

Interventional Neuroradiology | December 15, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251399755 Get It

Background Animal models are essential for evaluating endovascular device safety and efficacy. Rats offer advantages, such as genetic manipulability, lower cost, and shorter healing and breeding cycles, compared to large animals. These features support studying aneurysm healing mechanisms and enable high-throughput testing. We developed an optimal rat aneurysm model for device evaluation. Methods Saccular aneurysms were created at the origins of the left renal artery (LRA) with acetylsalicylic acid (ASA) (LRA/ASA group, n = 7); the right common iliac artery (RCIA) with ASA alone (RCIA/ASA group, n = 6) or ASA plus clopidogrel (CLP) (RCIA/ASA + CLP group, n = 7); and the left common iliac artery (LCIA) with ASA + CLP (LCIA/ASA + CLP group, n = 7). The origins of these arteries were surgically exposed. During temporary ligation of the vessel origin, the vessel was bisected and endoluminal elastase was incubated in the proximal stump for 10 min, followed by release of the proximal ligation and permanent ligation of the stump. Angiographical and histological analysis were performed 4 weeks post-procedure. Results Follow-up digital subtraction angiography revealed mean ± standard deviation aneurysm height/neck dimensions of 1.2 ± 0.4/1.2 ± 0.1, 2.9/3.1, 2.3 ± 0.6/1.9 ± 0.3, and 2.1 ± 0.6/2.0 ± 0.4 mm for the LRA/ASA, RCIA/ASA, RCIA/ASA + CLP, and LCIA/ASA + CLP groups, respectively. The survival rate was 29%, 17%, 71%, and 86% in the LRA/ASA, RCIA/ASA, RCIA/ASA + CLP, and LCIA/ASA + CLP groups, respectively. Histopathological analysis of these aneurysms confirmed the absence of the internal elastic lamina and revealed aneurysmal changes in the arterial wall, resembling the pathological findings observed in human aneurysm specimens. Conclusions Common iliac aneurysm models with ASA + CLP can be used to evaluate the safety and efficacy of endovascular devices.
Evaluating a calcium chloride–elastase combination for creating large aneurysms in the endovascular rabbit elastase model
Bilgin, Cem , Bayraktar, Esref Alperen , Ding, Yonghong , Hajj, G El , Oliver, Alexander A , Şenol, Yiğit Can , Kallmes, David F. , Kadirvel, Ramanathan , Ding, Yong-Hong , El Hajj, Gerard , Senol, Yigit Can , Bayraktar, Esref Alperen , Oliver, Alexander A , Bilgin, Cem

Interventional Neuroradiology | October 25, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251390598 Get It

Purpose Large aneurysms have a higher rupture risk, yet no available in vivo animal model consistently produces large aneurysms for testing endovascular therapies. Recent research suggests that adding calcium chloride (CaCl 2 ) to elastase yields larger aneurysms in a surgical rabbit model. We evaluated whether this effect translates to an endovascular approach by comparing aneurysm sizes created using elastase alone versus a CaCl 2 –elastase combination. Methods Aneurysms were created in the right common carotid artery of New Zealand rabbits. One group received 1 mL porcine elastase; the other received elastase plus 0.055 g CaCl 2 (0.5 M). After four weeks, patency was confirmed via digital subtraction angiography. Two blinded co-authors measured the neck, width, and height of the aneurysms. Aneurysm volumes were estimated using AngioCalc.com. Statistical analyses were performed using either the Mann–Whitney U -test or t -test based on data distribution. Results Twenty-nine (29) New Zealand rabbits were included in the study: six in the CaCl 2 and elastase groups, 23 in the elastase-alone group. All induced aneurysms remained patent at follow-up. Mean neck size was significantly larger in the CaCl 2 + elastase group than in the elastase-alone group (4.4 ± 1.1 mm vs 3.5 ± 0.95 mm; respectively, p = 0.02). Differences in width (4.1 ± 0.92 mm vs 3.4 ± 0.36 mm; p = 0.06), height (9.0 ± 1.1 mm vs 9.1 ± 2.1 mm; p = 0.46), and volume (83.5 ± 38.35 mm ³ vs 53.0 ± 16.94 mm³; p = 0.11) were not significant between CaCl 2 + elastase and elastase-alone, respectively. Conclusions CaCl 2 modestly increased neck size but did not significantly enlarge overall aneurysm dimensions. Further studies are needed to assess its utility in endovascular aneurysm models.
Idiopathic Intracranial Hypertension Animal Models and Venous Sinus Stenting: Status of Disease and Device-Focused Evidence
Ognard, Julien , Hajj, G El , Khabir, Sevda Alipour , Bayraktar, Esref Alperen , Kadirvel, Ramanathan , Kallmes, David F. , Brinjikji, Waleed , El Hajj, Gerard , Alipour Khabir, Sevda, Bayraktar, Esref Alperen , Ognard, Julien , Ghozy, Sherief

Brain Sciences | September 30, 2025 | Volume: 15 | Issue: 10 | Pages: 1064

10.3390/brainsci15101064 Get It

Background/Objectives: Idiopathic intracranial hypertension (IIH) often features dural venous sinus stenosis; venous sinus stenting (VSS) improves venous outflow and intracranial pressure, but most stents are off-label, and few are engineered for intracranial venous anatomy. The aim was to synthesize animal models relevant to IIH/VSS, catalogue stents used clinically for VSS and summarize corresponding animal data, appraise current preclinical VSS research, and propose a pragmatic preclinical evaluation framework. Methods: We performed a targeted search (PubMed, Web of Science, Scopus; through to May 2025), dual-screened the records in Nested Knowledge, and extracted the model/device characteristics and outcomes as per the predefined criteria. Results: We identified 65 clinical VSS studies; most were retrospective and used off-label carotid/peripheral/biliary stents (Precise, Zilver, and Wallstent were the most frequent). Recent dedicated systems (River, BosStent) have limited animal evidence; VIVA has GLP porcine venous peripheral data demonstrating its patency, structural integrity, and benign healing outcomes. Rodent models reproduce obesity/androgen drivers with modest, sustained ICP elevation; large animal models show the technical feasibility of in sinus implantation, but no chronic focal venous stenosis model fully mirrors the IIH condition. Conclusions: Despite broad clinical uptake, the translational underpinnings of VSS in IIH remain incomplete: most devices lack intracranial venous-specific preclinical validation, and there is no existing animal model that recapitulates both IIH biology and focal sinus stenosis.
Simulation of cerebrospinal fluid (CSF)-venous fistula embolization in a swine model: A technical video
Bayraktar, Esref Alperen , Cortese, Jonathan, Ognard, Julien , Hajj, G El , Bilgin, Cem , Kadirvel, Ramanathan , Kallmes, David F. , Brinjikji, Waleed , El Hajj, Gerard , Bayraktar, Esref Alperen , Ognard, Julien , Cortese, Jonathan , Bilgin, Cem

Interventional Neuroradiology | June 18, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251349656 Get It

Cerebrospinal fluid venous fistulas (CSFVF) can lead to spontaneous intracranial hypotension, causing debilitating symptoms in patients. The transvenous embolization technique has been developed to occlude leakage sites via an endovascular approach. However, the spinal venous anatomy remains relatively unfamiliar to many neurointerventionalists. This technical video presents a swine model designed to train physicians in navigating the spinal venous system, performing embolization injections, observing their spread, and testing new embolization systems for treating CSFVF. Although there are slight anatomical differences, the spinal venous system in swine closely resembles that of humans, including its navigability and employing liquid embolic agents. We successfully embolized multilevel spinal vasculature that can potentially drain into a fistula formation, without any complications.
Measuring artery diameter in rabbit angiograms for neurovascular disease modeling applications and device testing
Khan, YM , Franklin, J Ford, Bayraktar, Esref Alperen , Oliver, Alexander A , Ding, Yonghong , Lortscher, Sarah, Brinjikji, Waleed , Kadirvel, Ramanathan , Kallmes, David F. , Khan, Yasmine , Franklin, Jack , Bayraktar, Esref Alperen , Oliver, Alexander A , Ding, Yong-Hong , Lortscher, Sarah , Brinjikji, Waleed , Kadirvel, Ram , Kallmes, David F , Cortese, Jonathan

Interventional Neuroradiology | June 10, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251347398 Get It

Background and purpose New Zealand White Rabbits are a useful preclinical model for neurovascular research. Inducing right common carotid artery aneurysms in New Zealand White Rabbits gives researchers the ability to test neurovascular devices in vivo. This study takes advantage of archived angiograms to obtain vascular measurements of interest for future research in rabbit models. Methods Rabbit angiograms from endovascular studies conducted in-house between 2005 and 2024 were analyzed using ImageJ at points of interest along the thoracic and abdominal aorta. Using scale references, the diameters of various New Zealand White Rabbit (2.5–3.5 kg) arteries were measured for aneurysm models and controls. Anatomic vascular variations were categorized and recorded. Results Measurable artery diameters at 39 points of interest were recorded for 170 female New Zealand White Rabbits. Type 1 vascular anatomy was the most common rabbit aortic arch, characterizing 85% of identifiable rabbit anatomies in this study. Conclusion By making these measurements available, this study simplifies future neurovascular studies, allowing for vasculature to be selected by size depending on the application. Additionally, the study offers insight into the relationship between elastase-induced aneurysms and surrounding vasculature size and draws size comparisons between some key arteries of interest.
Endovascular rodent model using tail access and ultrasound guidance
Ognard, Julien , Hajj, G El , Lortscher, Sarah, Bayraktar, Esref Alperen , Brinjikji, Waleed , Kadirvel, Ramanathan , Kallmes, David F. , El Hajj, Gerard , Bayraktar, Esref Alperen , Oliver, Alexander A , Brinjikji, Waleed , Kadirvel, Ram , Ognard, Julien , Ding, Yonghong

Journal of NeuroInterventional Surgery | May 9, 2025 | Volume: 18 | Issue: 5 | Pages: 1487-1487

10.1136/jnis-2025-023444 Get It

We have developed a cost-effective method to study the fate of stents, particularly flow diverter stents placed in the abdominal aorta, in a rat model. This technique utilizes (caudal) tail artery access,1–5 thereby avoiding the need for surgical exposure of the femoral or carotid arteries and reducing procedural invasiveness,6 7 aligning with the principles of refinement and reduction in animal research.7 This approach may be particularly beneficial for studies requiring multiple or iterative vascular access. The use of ultrasound guidance further reduces costs and infrastructure requirements by eliminating the need for specialized angiography suites.8 This makes this technique accessible to a broader range of research settings, promoting wider adoption and collaboration in the field of endovascular research. A detailed demonstration of this method is provided in the accompanying educational video (video 1). Video 1 -Technical video describing the tail artery access and flow diverter deployment using ultrasound guidance.
Influence of Vessel Geometry, Flow Conditions, and Thrombin Concentration on Fibrin Accumulation and Cerebral Aneurysm Occlusion After Flow Diversion
Cebral, Juan R. , Mut, Fernando , Löhner, Rainald , Marsh, Laurel , Chitsaz, Alireza , Bilgin, Cem , Bayraktar, Esref Alperen , Kallmes, David F. , Kadirvel, Ramanathan , Bayraktar, Esref Alperen , Kallmes, David, Marsh, Laurel , Cebral, Juan R , Bilgin, Cem

International Journal for Numerical Methods in Biomedical Engineering | December 26, 2024 | Volume: 41 | Issue: 1 | Pages: No page available

10.1002/cnm.3904 Get It

ABSTRACT As the number of cerebral aneurysms treated with flow diverters continues to increase, it is important to understand what factors influence not only thrombus formation within the aneurysm cavity but also fibrin accumulation across the device and its associated disruption and blockage of the inflow stream. Both processes contribute to the eventual occlusion of the aneurysm or its continued patency and incomplete occlusion which may require future re‐treatment. To investigate fibrin accumulation on flow diverters placed across the neck of cerebral aneurysms, a previously developed computational model that couples flow and fibrin dynamics is used in combination with experimental in vitro models of cerebral aneurysms treated with flow diverters. Fibrin accumulation was previously investigated in four glass models of cerebral aneurysms with varying parent artery geometries placed in a flow loop at different flow rates. Corresponding computational models were constructed and compared with the experimental findings. The computational model based on fibrin production stimulated from flow shear stress and subsequent adhesion to device wires was able to reproduce and explain the fibrin accumulation patterns observed in the experimental aneurysms treated with flow diverters. Specifically, these models indicated that increasing vessel curvature, flow rate, and thrombin concentration induced faster fibrin accumulation and associated aneurysm inflow disruption and blockage. The models described and tested in this paper are valuable to understand the detailed mechanisms leading to aneurysm occlusion and healing or incomplete occlusions after treatment with flow diverting devices.
What can we learn from machine learning studies on flow diverter aneurysm embolization? A systematic review
Bayraktar, Esref Alperen , Cortese, Jonathan , Jabal, Mohamed Sobhi , Ghozy, Sherief , Orscelik, Atakan , Bilgin, Cem , Kadirvel, Ramanathan , Brinjikji, Waleed , Kallmes, David F, Ghozy, Sherief , Orscelik, Atakan , Cortese, Jonathan , Bayraktar, Esref Alperen , Kallmes, David F.

Journal of NeuroInterventional Surgery | December 18, 2024 | Volume: 17 | Issue: 11 | Pages: 1168-1173

10.1136/jnis-2024-022147 Get It

Background As the use of flow diverters has expanded in recent years, predicting successful outcomes has become more challenging for certain aneurysms. Objective To provide neurointerventionalists with an understanding of the available machine learning algorithms for predicting the success of flow diverters in occluding aneurysms. Methods This study followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, and the four major medical databases (PubMed, Embase, Scopus, Web of Science) were screened. The study included original research articles that evaluated the predictive abilities of various machine learning algorithms for determining the success of flow diverters in achieving aneurysm occlusion. Results Five studies out of 217 were included based on our criteria. The included studies used various variables (patient demographics, aneurysm and parent artery characteristics, flow diverter and hemodynamic-related features, and angiographic parametric imaging) to predict flow diverter treatment outcomes. The machine learning algorithms used, along with their respective accuracy rates, were as follows: logistic regression (61% and 85%), support vector machine (88%), Gaussian support vector machine (90%), linear support vector machine (85%), decision tree (80%), random forest (87%), k-nearest neighbors (83% and 85%), XGBoost (87%), CatBoost (86%), deep neural networks (77.9%), and recurrent neural networks (74%).Two studies trained the machine learning models with both all features and the most significant features. Both studies observed that the accuracy of machine learning models decreased by removing the insignificant features. Conclusion The current literature indicates that machine learning algorithms can be trained to predict the success of flow diverters with an accuracy of up to 90%.