Influence of Vessel Geometry, Flow Conditions, and Thrombin Concentration on Fibrin Accumulation and Cerebral Aneurysm Occlusion After Flow Diversion
Cebral, Juan R. , Mut, Fernando , Löhner, Rainald , Marsh, Laurel , Chitsaz, Alireza , Bilgin, Cem , Bayraktar, Esref Alperen , Kallmes, David F. , Kadirvel, Ramanathan , Bayraktar, Esref Alperen , Kallmes, David, Marsh, Laurel , Cebral, Juan R , Bilgin, Cem

International Journal for Numerical Methods in Biomedical Engineering | December 26, 2024 | Volume: 41 | Issue: 1 | Pages: No page available

10.1002/cnm.3904 Get It

ABSTRACT As the number of cerebral aneurysms treated with flow diverters continues to increase, it is important to understand what factors influence not only thrombus formation within the aneurysm cavity but also fibrin accumulation across the device and its associated disruption and blockage of the inflow stream. Both processes contribute to the eventual occlusion of the aneurysm or its continued patency and incomplete occlusion which may require future re‐treatment. To investigate fibrin accumulation on flow diverters placed across the neck of cerebral aneurysms, a previously developed computational model that couples flow and fibrin dynamics is used in combination with experimental in vitro models of cerebral aneurysms treated with flow diverters. Fibrin accumulation was previously investigated in four glass models of cerebral aneurysms with varying parent artery geometries placed in a flow loop at different flow rates. Corresponding computational models were constructed and compared with the experimental findings. The computational model based on fibrin production stimulated from flow shear stress and subsequent adhesion to device wires was able to reproduce and explain the fibrin accumulation patterns observed in the experimental aneurysms treated with flow diverters. Specifically, these models indicated that increasing vessel curvature, flow rate, and thrombin concentration induced faster fibrin accumulation and associated aneurysm inflow disruption and blockage. The models described and tested in this paper are valuable to understand the detailed mechanisms leading to aneurysm occlusion and healing or incomplete occlusions after treatment with flow diverting devices.
Modeling Fibrin Accumulation on Flow‐Diverting Devices for Intracranial Aneurysms
Cebral, Juan R. , Mut, Fernando , Löhner, Rainald , Marsh, Laurel , Chitsaz, Alireza , Bilgin, Cem , Bayraktar, Esref Alperen , Kallmes, David F. , Kadirvel, Ramanathan , Bayraktar, Esref Alperen , Kallmes, David, Marsh, Laurel , Cebral, Juan R , Bilgin, Cem

International Journal for Numerical Methods in Biomedical Engineering | November 6, 2024 | Volume: 40 | Issue: 12 | Pages: No page available

10.1002/cnm.3883 Get It

ABSTRACT The mechanisms leading to aneurysm occlusion after treatment with flow‐diverting devices are not fully understood. Flow modification induces thrombus formation within the aneurysm cavity, but fibrin can simultaneously accumulate and cover the device scaffold, leading to further flow modification. However, the interplay and relative importance of these processes are not clearly understood. A computational model of fibrin accumulation and flow modification after flow diversion treatment of cerebral aneurysms has been developed under the guidance of in vitro experiments and observations. The model is based on the loose coupling of flow and transport‐reaction equations that are solved separately by independent codes. Interaction or reactive terms account for thrombin production from prothrombin stimulated by thrombogenic metallic wires and inhibition by antithrombin as well as fibrin production from fibrinogen stimulated by thrombin and flow shear stress, and fibrin adhesion to device wires and already attached fibrin. The computational model was demonstrated and tested on idealized vessel and aneurysm geometries. The model was able to reproduce the salient features of fibrin accumulation after the deployment of flow‐diverting devices in idealized in vitro models of cerebral aneurysms. Namely, fibrin production in regions of high shear stress, initial accumulation at the inflow zone, and progressive occlusion of the device and corresponding flow attenuation. The computational model linking flow dynamics to fibrin production, transport, and adhesion can be used to investigate and better understand the effects that lead to fibrin accumulation and the resulting aneurysm inflow reduction and intra‐aneurysmal flow modulation.