Back to Authors

Castaño, Óscar

0000-0001-9212-784X

Mayo Clinic

Institute for Bioengineering of Catalonia

Citations 2

Catheter design primer for neurointerventionalists
Bilgin, Cem , Hutar, Jared, Li, Jiahui , Ribó, Marc , Kallmes, David F. , Ribo, Marc , Li, Jiahui , Castaño, Óscar

Journal of NeuroInterventional Surgery | December 7, 2022 | Volume: 15 | Issue: 11 | Pages: 1117-1121

10.1136/jnis-2022-019567 Get It

Neurovascular catheter technology has rapidly evolved over the past decade. While performance characteristics are well known to the practitioner, the design features of these new-generation catheters and their implications on performance metrics remain a mystery to most clinicians due to the limited number of available resources. This knowledge gap hampers informed device choices and also limits collaboration between clinicians and engineers. To aid fellow neurointerventionalists, in this primer we have summarized the basic concepts of catheter design and construction.
Trackability of distal access catheters: an in vitro quantitative evaluation of navigation strategies
Li, Jiahui , Tomasello, Alejandro , Requena, Manuel , Canals, Pere , Tiberi, Riccardo , Galve, Iñaki, Kallmes, David F. , Ribó, Marc , Ribo, Marc , Li, Jiahui , Requena, Manuel , Engel, Elisabeth , Castaño, Óscar , Tomasello, Alejandro

Journal of NeuroInterventional Surgery | April 21, 2022 | Volume: 15 | Issue: 5 | Pages: 496-501

10.1136/neurintsurg-2022-018889 Get It

Background In mechanical thrombectomy (MT), distal access catheters (DACs) are tracked through the vascular anatomy to reach the occlusion site. The inability of DACs to reach the occlusion site has been reported as a predictor of unsuccessful recanalization. This study aims to provide insight into how to navigate devices through the vascular anatomy with minimal track forces, since higher forces may imply more risk of vascular injuries. Methods We designed an experimental setup to monitor DAC track forces when navigating through an in vitro anatomical model. Experiments were recorded to study mechanical behaviors such as tension buildup against vessel walls, DAC buckling, and abrupt advancements. A multiple regression analysis was performed to predict track forces from the catheters’ design specifications. Results DACs were successfully delivered to the target M1 in 60 of 63 in vitro experiments (95.2%). Compared to navigation with unsupported DAC, the concomitant coaxial use of a microcatheter/microguidewire and microcatheter/stent retriever anchoring significantly reduced the track forces by about 63% and 77%, respectively (p<0.01). The presence of the braid pattern in the reinforcement significantly reduced the track forces regardless of the technique used (p<0.05). Combined coil and braid reinforcement configuration, as compared with coil alone, and a thinner distal wall were predictors of lower track force when navigating with unsupported DAC. Conclusions The use of microcatheter and stent retriever facilitate smooth navigation of DACs through the vascular tortuosity to reach the occlusion site, which in turn improves the reliability of tracking when positioning the DAC closer to the thrombus interface.