Macrowire-only direct aspiration first-pass technique for endovascular mechanical thrombectomy: Multicenter technical series using the 0.035″ aristotle Colossus wire
Background Larger “macrowires” may facilitate microcatheter-free delivery of large-bore aspiration catheters (ACs) for intracranial endovascular mechanical thrombectomy. We examined the safety and efficacy of the Aristotle Colossus Guidewire for this use. Methods In this retrospective analysis of prospective data from 12 institutions, we identified anterior circulation endovascular mechanical thrombectomy cases involving the Aristotle Colossus guidewire over a 12-month period. The primary efficacy endpoint was successful delivery of the AC to the site without the use of adjunct devices. Multivariable logistic regression was performed with clinically relevant covariables. Results In 122 patients (median age 74 years (interquartile range (IQR) 63–82)), most intracranial occlusions were in the M1 segment of the middle cerebral artery (95/122, 78.0%). The primary endpoint of microcatheter-free AC delivery was met in 87.7% (107/122) of patients; 93/122 (76.2%) patients underwent microcatheter-free delivery with successful reperfusion via contact aspiration (modified thrombolysis in cerebral infarction grade ≥ 2B). The median number of passes was 1 (IQR 1–2). Multivariable regression demonstrated that severe internal carotid artery tortuosity or cervical loop presence (odds ratio (OR): 0.09, 95% confidence interval (CI): 0.01–0.54, p = 0.01) and presence of intracranial atherosclerotic disease (OR: 0.15, 95% CI: 0.03–0.83, p = 0.03) were significantly associated with lower odds of successful AC delivery over the guidewire. Intraprocedural vasospasm occurred in 4.9% (6/122) of cases; there were no reports of vessel dissection or perforation. Conclusions We demonstrate the favorable performance of the Aristotle Colossus guidewire for anterior circulation ischemic stroke intervention. The macrowire appears to safely facilitate navigation of the neurovasculature by large-bore ACs without the need for microcatheter and/or stentriever.
Multicenter analysis of flow diversion for recurrent/persistent intracranial aneurysms after stent-assisted coiling
Background Flow-diverter stents (FDS) have become the standard of care for a wide range of intracranial aneurysms, but their efficacy/safety in the context of recurrent/recanalized aneurysms following stent-assisted coiling (SAC) is not well established. We evaluate the outcomes of FDS retreatment in a large multicenter cohort. Methods We retrospectively analyzed data from 118 patients across 22 institutions who underwent FDS retreatment for recurrent/persistent aneurysms after SAC (2008–22). The primary outcome was angiographic occlusion status at last follow-up, categorized as complete (100%), near-complete (90–99%), or incomplete (<90%) occlusion. Secondary outcomes included procedural complications and clinical outcomes measured by the modified Rankin Scale (mRS). Results A total of 118 patients (median age 57, 74.6% female) with median follow-up of 15.3 months were identified. Complete occlusion was achieved in 62.5% and near-complete occlusion in 25%. FDS deployment within the pre-existing stent was successful in 98.3% of cases. Major complications occurred in 3.4% of cases, including postoperative aneurysmal rupture with resultant mortality (1.6%) and thromboembolic events with long-term disability (1.6%). Favorable clinical outcomes (mRS 0–2) were observed in 95.1% of patients. Wider aneurysm neck diameter was a significant predictor of incomplete occlusion (adjusted OR (aOR) 1.23 per mm, P=0.044), with male sex trending towards association with non-occlusion (aOR 3.2, P=0.07), while baseline hypertension was associated with complete occlusion (aOR 0.32, P=0.048). Conclusions FDS treatment for recurrent/residual aneurysms after SAC represents a viable treatment option for these challenging cases with acceptable safety and reasonable occlusion rates, although lower than de novo FDS occlusion rates.