Macrowire-only direct aspiration first-pass technique for endovascular mechanical thrombectomy: Multicenter technical series using the 0.035″ aristotle Colossus wire
Background Larger “macrowires” may facilitate microcatheter-free delivery of large-bore aspiration catheters (ACs) for intracranial endovascular mechanical thrombectomy. We examined the safety and efficacy of the Aristotle Colossus Guidewire for this use. Methods In this retrospective analysis of prospective data from 12 institutions, we identified anterior circulation endovascular mechanical thrombectomy cases involving the Aristotle Colossus guidewire over a 12-month period. The primary efficacy endpoint was successful delivery of the AC to the site without the use of adjunct devices. Multivariable logistic regression was performed with clinically relevant covariables. Results In 122 patients (median age 74 years (interquartile range (IQR) 63–82)), most intracranial occlusions were in the M1 segment of the middle cerebral artery (95/122, 78.0%). The primary endpoint of microcatheter-free AC delivery was met in 87.7% (107/122) of patients; 93/122 (76.2%) patients underwent microcatheter-free delivery with successful reperfusion via contact aspiration (modified thrombolysis in cerebral infarction grade ≥ 2B). The median number of passes was 1 (IQR 1–2). Multivariable regression demonstrated that severe internal carotid artery tortuosity or cervical loop presence (odds ratio (OR): 0.09, 95% confidence interval (CI): 0.01–0.54, p = 0.01) and presence of intracranial atherosclerotic disease (OR: 0.15, 95% CI: 0.03–0.83, p = 0.03) were significantly associated with lower odds of successful AC delivery over the guidewire. Intraprocedural vasospasm occurred in 4.9% (6/122) of cases; there were no reports of vessel dissection or perforation. Conclusions We demonstrate the favorable performance of the Aristotle Colossus guidewire for anterior circulation ischemic stroke intervention. The macrowire appears to safely facilitate navigation of the neurovasculature by large-bore ACs without the need for microcatheter and/or stentriever.
Wingspan stent delivery catheter fracture and the TRAP technique for endovascular salvage
Background Intracranial atherosclerotic disease may result in ischemic infarction and has a high rate of recurrent ischemic strokes despite medical therapy. Patients who fail medical therapy may undergo endovascular treatment with cerebral artery angioplasty and possible Wingspan stent placement. We present a unique case of Wingspan delivery microcatheter fracture that resulted in a retained foreign body and an endovascular salvage maneuver. Case description An elderly patient presented with an acute ischemic stroke due to a severe stenosis in the proximal left middle cerebral artery (MCA). The patient failed non-invasive medical treatment and underwent endovascular treatment with angioplasty and Wingspan stent placement. Following Wingspan stent deployment, the stent delivery catheter fractured, and the retained catheter fragment resulted in MCA occlusion. The foreign body was retrieved by balloon catheter inflation within an intermediate catheter adjacent to the proximal end of the fractured catheter and removal of the entire construct (TRAP technique). Conclusions Wingspan delivery microcatheter fracture is a rare event. The TRAP technique may be used for successful retrieval of a retained foreign body.