Back to Authors

Mirshahi, Shervin

https://orcid.org/0000-0002-1136-3494

Mayo Clinic

Brigham and Women's Hospital

Citations 3

Impact of smoking on recurrence rates among wide-neck intracranial aneurysms treated with Woven EndoBridge: a multicenter retrospective study
Vaishnav, Dhrumil , Adeeb, Nimer , Aslan, Assala , Cancelliere, Nicole M., McLellan, Rachel , Ghozy, Sherief, Lay, Sovann V. , Guenego, Adrien , Premat, Kévin , Möhlenbruch, Markus, Kral, Michael , Doron, Omer , Salem, Mohamed M. , Foreman, Paul M. , Vachhani, Jay A. , Shaikh, Hamza, Župančić, Vedran , Ayberk, Gıyas , Güneş, Yasin Celal , Rabinov, James D. , Ren, Yifan , Michelozzi, Caterina , Elens, Stéphanie , Starke, Robert M., Hassan, A. , Ogilvie, Mark , Nguyên, Anh , Jones, Jesse , Brinjikji, Waleed , Nawka, Marie Teresa , Psychogios, Marios, Ulfert, Christian , Diestro, Jose Danilo Bengzon , Pukenas, Bryan , Burkhardt, Jan‐Karl , Martinez-Gutierrez, Juan Carlos, Sheth, Sunil G. , Spiegel, Gary, Lubicz, Boris , Puri, Ajit S., Pero, Guglielmo , Nossek, Erez , Raz, Eytan, Griessenauer, Christoph J., Asadi, Hamed , Siddiqui, Adnan, Brook, Allan , Haranhalli, Neil , Ducruet, Andrew F. , Albuquerque, Felipe C. , Regenhardt, Robert W. , Stapleton, Christopher J. , Kan, Peter, Kalousek, Vladimir , Lylyk, Pedro , Boddu, Srikanth , Knopman, Jared , Tjoumakaris, Stavropoula I., Clarençon, Frédéric, Cuellar-Saenz, Hugo H., Patel, Aman B. , Altschul, David , _, _, Spears, Julian , Sundararajan, Sri Hari , Balush, Ali Al, Inoue, Yasuaki , Mirshahi, Shervin , Harker, Pablo, Tutino, Vincent M., Brehm, Alex , Diestro, Jose Danilo B , Shotar, Eimad , Nguyen, Anh , Pero, Guglielmo , Kalousek, Vladimir , Altschul, David J , Regenhardt, Robert W , Ulfert, Christian , Lay, Sovann V , Essibayi, Muhammed Amir , Musmar, Basel , Salim, Hamza , Cancelliere, Nicole M , Algin, Oktay , Ghozy, Sherief , Renieri, Leonardo , Carnevale, Joseph Anthony , Saliou, Guillaume , Mastorakos, Panagiotis , Naamani, Kareem El , Shotar, Eimad , Möhlenbruch, Markus , Chung, Charlotte , Lylyk, Iván , Hafeez, Muhammad Ubaid , Catapano, Joshua S , Waqas, Muhammad , Schirmer, Clemens M. , Piano, Mariangela , Kühn, Anna Luisa , Hassan, Ameer E , Psychogios, Marios‐Nikos , Huynh, Thien , Martinez-Gutierrez, Juan Carlos , Sheth, Sunil A., Tawk, Rabih G. , Panni, Pietro , Puri, Ajit S , Raz, Eytan , Killer-Oberpfalzer, Monika , Griessenauer, Christoph J. , Aziz‐Sultan, Mohammad Ali , Tjoumakaris, Stavropoula , Clarençon, Frédéric , Limbucci, Nicola , Cuellar, Hugo , Jabbour, Pascal , Mendes Pereira, Vitor , Dmytriw, Adam A. , _, _, Dibas, Mahmoud , Vranic, Justin E. , Alotaibi, Naif M. , Harker, Pablo , Sporns, Peter Bernhard

Journal of Neurosurgery | January 31, 2025 | Volume: 142 | Issue: 6 | Pages: 1732-1740

10.3171/2024.10.jns241058 Get It

OBJECTIVE Tobacco smoking is among the factors known to significantly augment the risk of untreated intracranial aneurysm (IA) growth and rupture. Smoking appears to have a variable effect on different endovascular treatment modalities. The impact of smoking on the safety, efficacy, and outcomes of Woven EndoBridge (WEB) device use for wide-neck IAs has not been evaluated. This study aimed to investigate the outcomes of WEB devices by smoking status. METHODS A retrospective multicenter analysis was conducted on the data of patients from 36 sites worldwide treated with the WEB device for intracranial saccular aneurysms. Patients were stratified based on smoking status (current, former, and never smokers). The Student t-test and chi-square test were performed for continuous and categorical variables, respectively. Multivariable logistic regression was used to adjust for confounders. RESULTS Of 1376 patients with available smoking status, 504 were current smokers, 358 were former smokers, and 514 were never smokers. Upon adjusting for significant confounders, no association was found between smoking and recurrence outcomes (OR 1.39, 95% CI 0.69–2.80; p = 0.36), thromboembolic and hemorrhagic complications, and mortality among IAs treated with the WEB device. There was no statistically significant difference in outcomes between former and never smokers (OR 1.23, 95% CI 0.70–2.18; p = 0.46). The location of aneurysms differed between smoking groups, with former smokers having more anterior circulation aneurysms compared with current and never smokers (99.0% vs 96.9% vs 95.3%; p = 0.01). In terms of clinical symptoms, headache and dizziness were more common in the never smokers compared with current and former smokers (13.9% vs 8.9% vs 7.7%, p = 0.01). CONCLUSIONS This large-scale study suggests no significant correlation between smoking and the recurrence of IAs treated with the WEB device. Biological studies are warranted to better understand the biological impact of smoking on the growth and rupture of treated IAs.
Stent-assisted Woven EndoBridge device for the treatment of intracranial aneurysms: an international multicenter study
Diestro, Jose Danilo Bengzon , Adeeb, Nimer , Regenhardt, Robert W. , Guenego, Adrien , Lay, Sovann V. , Balushi, Ali Al , Premat, Kévin , Namaani, Kareem El, Möhlenbruch, Markus , Foreman, Paul M. , Vachhani, Jay A. , Župančić, Vedran , Rai, Hamid, Tutino, Vincent M. , Mirshahi, Shervin , Ghozy, Sherief , Rabinov, James D. , Ren, Yifan , Goren, Oded , Michelozzi, Caterina , Elens, Stéphanie , Starke, Robert M. , Nguyên, Anh , Jones, Jesse , Psychogios, Marios, Spears, Julian , Marotta, Thomas R. , Bres-Bullrich, Maria , Mayich, Michael , Salem, Mohamed M. , Burkhardt, Jan‐Karl , Jankowitz, Brian T. , Ulfert, Christian , Lubicz, Boris , Puri, Ajit S , Pero, Guglielmo , Asadi, Hamed , Ducruet, Andrew F. , Albuquerque, Felipe C , Patel, Nirav J. , Kan, Peter , Kalousek, Vladimir , Lylyk, Pedro , Boddu, Srikanth , Stapleton, Christopher J. , Knopman, Jared , Tjoumakaris, Stavropoula , Clarençon, Frédéric , Patel, Aman B. , Tawk, Rabih, Ghozy, Sherief , Diestro, Jose Danilo B , Shotar, Eimad , Tutino, Vincent M , Nguyen, Anh , Pero, Guglielmo , Kalousek, Vladimir , Regenhardt, Robert W , Ulfert, Christian , Lay, Sovann V , Burkhardt, Jan‐Karl , Dibas, Mahmoud , Vranic, Justin E. , Renieri, Leonardo , Shotar, Eimad , Saliou, Guillaume , Lylyk, Iván , Hafeez, Muhammad Ubaid , Rutledge, Caleb , Harker, Pablo , Alotaibi, Naif M. , Schirmer, Clemens M. , Piano, Mariangela , Kühn, Anna Luisa , Hassan, Ameer E , Salehani, Arsalaan , Psychogios, Marios‐Nikos , Mendes Pereira, Vitor , Parra-Fariñas, Carmen , Bullrich, María Bres , Domingo, Ricardo A. , Huynh, Thien , Tawk, Rabih G. , Panni, Pietro , Griessenauer, Christoph J. , Siddiqui, Adnan H. , Jabbour, Pascal , Limbucci, Nicola , Aziz‐Sultan, Mohammad Ali , Cuellar, Hugo , Cognard, Christophe , Dmytriw, Adam A.

Journal of Neurosurgery | October 21, 2023 | Volume: 140 | Issue: 4 | Pages: 1071-1079

10.3171/2023.8.jns235 Get It

OBJECTIVE The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment. In addition, the authors also sought to determine the predictors of a concomitant stent in aneurysms treated with the WEB device. METHODS The data for this study were taken from the WorldWideWEB Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups based on treatment: stent-assisted WEB and WEB device alone. The authors compared clinical and radiological outcomes of both groups. Univariable and multivariable binary logistic regression analyses were performed to determine factors that predispose to stent use. RESULTS The study included 691 intracranial aneurysms (31 with stents and 660 without stents) treated with the WEB device. The adequate occlusion status did not differ between the two groups at the latest follow-up (83.3% vs 85.6%, p = 0.915). Patients who underwent stenting had more thromboembolic (32.3% vs 6.5%, p < 0.001) and procedural (16.1% vs 3.0%, p < 0.001) complications. Aneurysms treated with a concomitant stent had wider necks, greater heights, and lower dome-to-neck ratios. Increasing neck size was the only significant predictor for stent use. CONCLUSIONS This study demonstrates that there is no difference in the degree of aneurysm occlusion between the two groups; however, complications were more frequent in the stent group. In addition, a wider aneurysm neck predisposes to stent assistance in WEB-treated aneurysms.