Background: Ischemic stroke remains a leading cause of morbidity and mortality worldwide. Cardioembolic sources account for a significant proportion of these events, necessitating accurate identification of underlying structural heart abnormalities. Traditionally, transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) have been utilized for this purpose, although both have limitations. Cardiac computed tomography (CCTA) has emerged as a potential alternative, offering non-invasive imaging with high sensitivity and specificity for detecting intracardiac thrombi. Objective: This study aimed to evaluate the diagnostic yield of CCTA compared to TTE and TEE in detecting high-risk cardioaortic sources of embolism, including left ventricular (LV) thrombus, left atrial (LA) thrombus, valvular thrombus, and ulcerated aortic plaques, in patients with ischemic stroke. Methods: We conducted a retrospective, single-center cohort study at Mayo Clinic, Rochester, MN, including 426 ischemic stroke patients who underwent CCTA within 30 days of stroke onset between March 2019 and June 2023. We compared the diagnostic yields of CCTA, TTE, and TEE in detecting structural cardiac sources of embolism. Results: The overall diagnostic yield of CCTA for detecting high-risk cardioaortic sources was 15.5%. Specifically, CCTA identified LV thrombus in 2.3% of patients, LA thrombus in 4.0%, valvular thrombus in 2.8%, and ulcerated aortic plaques in 7.0%. In comparative analysis, CCTA demonstrated a higher yield than TTE (16.0% vs 3.5%, p < 0.001) and a comparable yield to TEE (25.3% vs 20.7%, p = 0.47) in detecting these sources. Conclusions: CCTA proved to be a viable option for identifying high-risk structural sources of cardioembolism in ischemic stroke patients. Its non-invasive nature, coupled with the ability to perform imaging soon after stroke onset, underscores its clinical utility. However, further prospective and blinded studies are required to validate these findings and fully establish the efficacy of CCTA in this context.
OBJECTIVE The Woven EndoBridge (WEB) device was approved to treat wide-necked bifurcation aneurysms. The device is designed as an intrasaccular flow disruptor covering aneurysm widths up to 10 mm. Although prior studies combined all aneurysm sizes, it is known that aneurysms behave differently in response to endovascular treatment based on their size. Therefore, the authors’ objective was to identify ideal middle cerebral artery (MCA) aneurysm width and neck sizes most suitable for WEB treatment. METHODS The WorldWideWEB consortium is a large multicenter retrospective database that analyzes intracranial aneurysms treated with the WEB device. In this study, all unruptured MCA bifurcation aneurysms with available measurements were included. Cutoff values based on aneurysm width and neck in relation to aneurysm occlusion status were measured using the receiver operating characteristic (ROC) curve. Propensity score matching (PSM) was then used to compare treatment outcomes between aneurysms smaller and larger than the cutoff value for both width and neck size. RESULTS The ideal cutoff values for MCA bifurcation aneurysm width and neck were 6.1 mm and 4.6 mm, respectively. On PSM, 87 matched pairs were compared based on width size (≤ 6.1 mm and > 6.1 mm), and 77 matched pairs were compared based on neck size (≤ 4.6 mm and > 4.6 mm). There was a significant difference in adequate aneurysm occlusion between aneurysms smaller and larger than those cutoff values for both widths (93% vs 76%, p = 0.0017) and neck sizes (90% vs 70%, p = 0.0026). The retreatment rate was also significantly higher for larger aneurysms in both parameters. CONCLUSIONS This study shows that MCA bifurcation aneurysms ≤ 6.1 mm in width and ≤ 4.6 mm in neck size are significantly better candidates for WEB treatment, leading to improved occlusion status and reduced retreatment rate, which are important considerations when using WEB devices.
Association of preprocedural antiplatelet use with decreased thromboembolic complications for intracranial aneurysms undergoing intrasaccular flow disruption
OBJECTIVE This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19–0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25–0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38–10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26–8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04–0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48–230, p = 0.024). CONCLUSIONS The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.