Abstract Purpose Although the Woven EndoBridge (WEB) device is increasingly used for the treatment of wide-neck intracranial aneurysms, including in the acute rupture setting, comparative evidence assessing the impact of rupture status remains limited. This study compared angiographic, safety, and clinical outcomes between ruptured and unruptured intracranial aneurysms treated with WEB. Methods We conducted a retrospective analysis of prospectively collected data from the multicenter cohort registry WorldWideWEB, including consecutive adult patients with intracranial aneurysms treated with the WEB. Patients were stratified into groups of ruptured and unruptured aneurysms. Propensity score matching was used to balance baseline characteristics between both groups. Retreatment rate was the primary outcome. Secondary outcomes included mRS, safety events (thromboembolic complications) and angiographic outcomes (periprocedurally and last follow-up). Results Among 1,220 patients, 342 (28.0%) presented with ruptured aneurysms. There was no significant difference in the rate of thromboembolic complications between groups (11.8% vs 5.9%, p = 0.056). At follow-up, adequate occlusion was lower (82.2% vs 93.3%, p < 0.002) and functional outcomes were worse (mRS ≥2 in 34.1% vs 21.9%, p = 0.012) among patients with ruptured aneurysms. Periprocedural adequate occlusion (53.3% vs 53.8%, p>0.9) and retreatment rates (11.8% vs 7.1%, p = 0.14) did not differ between groups after matching. Conclusion Ruptured aneurysms demonstrated expected inferior follow-up functional and angiographic outcomes when compared with unruptured aneurysms, but no difference in retreatment rate and procedural safety. These findings support WEB as a safe and effective treatment option for appropriately selected ruptured intracranial aneurysms in routine clinical practice.
Endovascular Treatment of Stroke Due to Medium-Vessel Occlusion
Background Intrasaccular devices have become increasingly popular in the treatment of cerebral aneurysms, particularly at the bifurcation. Here we evaluate the Contour Neurovascular System, an intrasaccular device for the endovascular treatment of cerebral aneurysms, in a multicenter cohort study, the largest to the best of our knowledge. Methods Consecutive patients with intracranial aneurysms treated with the Contour Neurovascular System between February 2017 and October 2022 at 10 European neurovascular centers were prospectively collected and retrospectively reviewed. Patient and aneurysm characteristics, procedural details, and angiographic and clinical outcomes were evaluated. Results During the study period, 279 aneurysms (median age of patients 60 years, IQR 52–68) were treated with Contour. In 83.2% of patients the device was placed electively, whereas the remaining patients were treated in the setting of acute subarachnoid hemorrhage. The most common locations were the middle cerebral artery (26.5%) followed by the anterior communicating region (26.2%). Median aneurysm dome and neck size were 5.2 mm (IQR 4.2–7) and 3.9 mm (IQR 3–5). Contour size 7 (39%) and 9 (25%) were most used. Thromboembolic and hemorrhagic complications occurred in 6.8% and 0.4% of aneurysms, respectively. Raymond-Roy 1 and 2 occlusions at last follow-up were achieved in 63.2% and 28.3%, respectively, resulting in adequate occlusion of 91.5% of aneurysms. Conclusion This is the largest multicenter study reporting the outcome on the Contour Neurovascular System. At 1 year, the self-evaluated data on safety and efficacy are comparable to data of existing intrasaccular devices. Contour is a promising technology in the treatment of cerebral aneurysms.