Abstract Background Perianal fistulas and abscesses occur commonly as complications of pediatric Crohn’s disease (CD). A validated imaging assessment tool for quantification of perianal disease severity and activity is needed to evaluate treatment response. We aimed to identify magnetic resonance imaging (MRI)-based measures of perianal fistulizing disease activity and study design features appropriate for pediatric patients. Methods Seventy-nine statements relevant to MRI-based assessment of pediatric perianal fistulizing CD activity and clinical trial design were generated from literature review and expert opinion. Statement appropriateness was rated by a panel (N = 15) of gastroenterologists, radiologists, and surgeons using modified RAND/University of California Los Angeles appropriateness methodology. Results The modified Van Assche Index (mVAI) and the Magnetic Resonance Novel Index for Fistula Imaging in CD (MAGNIFI-CD) were considered appropriate instruments for use in pediatric perianal fistulizing disease clinical trials. Although there was concern regarding the use of intravascular contrast material in pediatric patients, its use in clinical trials was considered appropriate. A clinically evident fistula tract and radiologic disease defined as at least 1 fistula or abscess on pelvic MRI were considered appropriate trial inclusion criteria. A coprimary clinical and radiologic end point and inclusion of a patient-reported outcome were also considered appropriate. Conclusion Outcomes of treatment of perianal fistulizing disease in children must include MRI. Existing multi-item measures, specifically the mVAI and MAGNIFI-CD, can be adapted and used for children. Further research to assess the operating properties of the indices when used in a pediatric patient population is ongoing.
High-resolution computed tomography angiography of the orbit using a photon-counting computed tomography scanner
Background and Purpose Recent introduction of photon counting detector (PCD) computed tomography (CT) scanners into clinical practice further improve CT angiography (CTA) depiction of orbital arterial vasculature compared to conventional energy integrating detector (EID) CT scanners. PCD-CTA of the orbit can provide a detailed arterial roadmap of the orbit which can de diagnostic on its own or serve as a helpful planning adjunct for both diagnostic and therapeutic catheter-based angiography of the orbit. Methods For this review, EID and PCD-CT imaging was obtained in 28 volunteers. The volume CT dose index was closely matched. A dual-energy scanning protocol was used on EID-CT. An ultra-high-resolution (UHR) scan mode was used on PCD-CT. Images were reconstructed at 0.6 mm slice thickness using a closely matched medium-sharp standard resolution (SR) kernel. High-resolution (HR) images with the sharpest quantitative kernel were also reconstructed on PCD-CT at the thinnest slice thickness of 0.2 mm. A denoising algorithm was applied to the HR image series. Results The imaging description of the orbital vascular anatomy presented in this work was derived from these patients’ PCD-CTA images in combination with review of the literature. We found that orbital arterial anatomy is much better depicted with PCD-CTA, and this work can serve primarily as an imaging atlas of the normal orbital vascular anatomy. Conclusion With recent advances in technology, arterial anatomy of the orbit is much better depicted with PCD-CTA as opposed to EID-CTA. Current orbital PCD-CTA technology approaches the necessary resolution threshold for reliable evaluation of central retinal artery occlusion.
High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose
Objectives The aim of this study was to evaluate the high-helical pitch, multienergy (ME) scanning mode of a clinical dual-source photon-counting detector (PCD) computed tomography (CT) and the benefit of virtual monoenergetic images (VMIs) for low-contrast-dose coronary CT angiography (CTA). Materials and Methods High-pitch (3.2) ME coronary CTA was performed in PCD-CT in 27 patients using low contrast dose (30 mL of iohexol 350 mg/mL) and in 26 patients at routine contrast dose (60 mL). Low-energy-threshold 120 kV images (also known as T3D images) and 50 kiloelectron volts (50 keV) and 100 kiloelectron volts (100 keV) VMIs were reconstructed using a 1024 × 1024 matrix and 0.6-mm slices. The CT numbers, noise, and contrast-to-noise ratio (CNR) were measured in the ascending aorta (AA), left main coronary artery (LMCA), and distal left anterior descending (LAD) artery. Confidence in grading luminal stenosis with calcific plaque, noncalcific plaque, and stent was evaluated by 2 independent readers on a 0–100 scale (0 the lowest), and a CAD-RADS score was assigned. Image contrast enhancement, sharpness, noise, artifacts, and overall image quality were rated using a 5-point ordinal scale (1 the lowest). Results The radiation doses (CTDI) in low- and routine-contrast cohorts were 2.5 ± 0.6 mGy and 3.1 ± 1.7 mGy, respectively ( P = 0.12). At all measured locations, the mean CT number was >300 HU in 120 kV (LMCA 382.9 ± 76.2, distal LAD 341.0 ± 53.9, AA 399.5 ± 76.1) and 50 keV images (LMCA 667.5 ± 139.9, distal LAD 578.1 ± 121.5, AA 700.8 ± 142.5) in the low-contrast cohort, with a 96% increase in CT numbers for 50 keV over 120 kV. The CT numbers were significantly higher ( P < 0.0001) in 50 keV than 120 kV and 100 keV VMI. The CNR was also significantly ( P < 0.0001) higher in 50 keV than 120 kV and 100 keV images in all vessels. Confidence in the assessment of luminal stenosis in the presence of calcific plaque was significantly higher ( P = 0.001) with the addition of 100 keV VMI (median score, 100) than using 50 keV alone (median score, 70) and 120 kV (median score, 70) for reader 1, but no significant differences were seen for reader 2 who had same median scores of 100 for all image types. The confidence in the assessment of luminal stenosis within a stent improved with the use of 100 keV images for both readers (reader 1: median scores for 50 + 100 keV = 100, 50 keV = 82.5, 120 kV = 82.5; reader 2: 50 + 100 keV = 100, 50 keV = 90, 120 kV = 90). There were no significant differences in confidence scores for assessment of luminal stenosis from noncalcific plaques for both readers. The reader-averaged qualitative scores for vascular enhancement and overall image quality were significantly higher for 50 keV VMI than for 120 kV images in both low- and routine-contrast dose cohorts. The image sharpness was nonsignificantly higher at 50 keV VMI than 120 kV images, and the artifact score was comparable for 50 keV VMI and 120 kV images. The noise was higher in 50 keV VMI than in 120 kV images. Conclusions High-pitch ME PCD-CT mode produced diagnostic quality coronary CTA images at low radiation and iodinated contrast doses. The availability of ME VMIs significantly improved the CNR, overall image quality, and confidence in assessment of luminal stenosis in the presence of calcific plaques and stents, and resulted in change of CAD-RADS categories in 9 patients.
P311 Reliability of computed tomography enterography for evaluation of stricturing Crohn’s disease: Development of a Crohn’s disease stricture index
Abstract Background Computed tomography enterography (CTE) is frequently used to assess stricturing Crohn’s disease (CD). However, the reliability of CTE items used for assessment has not been established and there is no validated radiologic stricture severity index. Methods We conducted a retrospective study of 43 patients with symptomatic, terminal ileal stricturing CD. Four radiologists assessed a comprehensive list of pre-defined radiologic items potentially associated with stricture severity in 48 CTE scans in two separate rounds in random order. Reliability was quantified using the intraclass correlation coefficient (ICC). Items with at least moderate (ICC≥0.41) inter-rater reliability that were correlated with a visual analogue scale of overall stricture severity were candidate items for the development of a CTE stricture index. Results Inter-rater reliability was almost perfect for assessment of luminal diameter of pre-stenotic dilation (ICC 0.817 [95% confidence interval 0.703, 0.878]), substantial for stricture length (ICC 0.628 [0.419, 0.797]), and moderate for stricture wall thickness (0.482 [0.330, 0.601]). Intra-rater reliability was almost perfect (ICC ≥ 0.850) for all three items. A stricture severity index was derived and was well calibrated (optimism-adjusted calibration slope = 1.009), with scores calculated as the sum of stricture length (cm) + luminal diameter of pre-stenotic dilation (mm) + 5 x stricture wall thickness (mm). Conclusion Stricture length, prestenotic dilation, and stricture wall thickness can be reliably assessed, and are component items for a novel CTE stricture index (CTE-SI) of stricture severity for CD-related terminal ileal strictures. Additional external index validation for clinical and research contexts is required.
P270 A global consensus on the definitions, diagnosis and management of fibrostenosing small bowel Crohn’s disease
Abstract Background Small bowel fibrostenotic strictures are common in patients with Crohn’s disease (CD). No global consensus recommendations on definitions, diagnosis and clinical management are available. Methods Several systematic reviews followed by a RAND/University of California Los Angeles appropriateness study on the definitions, diagnosis and clinical management of fibrostenosing CD in clinical practice were performed. A panel of 28 global experts and a patient representative were convened. They assessed a total of 152 candidate items. The items were subsequently evaluated for appropriateness. Results No accurate predictive biomarkers are available for naïve or anastomotic fibrostenosing strictures. Accurate diagnosis of fibrostenosing CD requires cross-sectional imaging which should evaluate bowel wall thickness, luminal narrowing and prestenotic dilatation. A potential inflammatory component should be assessed. Abdominal cross-sectional imaging was considered necessary prior to any treatment decision. The panel proposed an approach to medical, endoscopic, and surgical therapies (Figure 1 and Table 1). Technical characteristics for endoscopic balloon dilation and follow up strategies after successful dilation therapy were identified. Appropriateness, types and performance of different surgical approaches in various settings were evaluated. Conclusion This global consensus provides clinical guidance for the diagnostic and therapeutic management of patients with fibrostenotic CD.
Durable Response in Patients With Refractory Fistulizing Perianal Crohn’s Disease Using Autologous Mesenchymal Stem Cells on a Dissolvable Matrix: Results from the Phase I Stem Cell on Matrix Plug Trial
BACKGROUND: Refractory perianal Crohn’s disease remains notoriously difficult to treat. We developed a novel technology using a commercially available bioabsorbable fistula plug to deliver autologous adipose-derived mesenchymal stem cells. OBJECTIVE: This study aimed to assess therapeutic safety and feasibility in the completed STOMP (stem cells on matrix plugs) phase 1 clinical trial. DESIGN: Prospective single-arm phase I clinical trial. SETTING: Tertiary academic medical center. PATIENTS: Adults (aged 18–65 y) with complex single-tract Crohn’s disease perianal fistula who have failed conventional therapy were included in this study. INTERVENTION: Autologous adipose-derived mesenchymal stem cells were isolated, ex vivo culture expanded, and seeded onto a commercially available bioabsorbable fistula plug. Six weeks later, patients returned to the operating room for removal of the seton and placement of the stem cell-loaded plug. MAIN OUTCOME MEASURES: Patients were followed up for a total of 8 visits through 12 months. Safety was the primary end point; clinical healing and MRI response were secondary end points. RESULTS: Twenty patients (12 females; mean age 36 y) were treated with the stem cell–loaded plug. Of the 20 patients enrolled, 3 were not included in the 12-month analysis because of study withdrawal. Through 12 months, no patient experienced a serious adverse event related to the stem cell–loaded plug. Four patients experienced 7 serious adverse events and 12 patients experienced 22 adverse events. Complete clinical healing occurred in 14 of 18 patients at 6 months and 13 of 17 patients at 12 months. MRI response was observed in 12 of 18 patients at 6 months. LIMITATIONS: The main limitations were the small sample size and restrictive inclusion criteria. CONCLUSIONS: A stem cell–loaded plug can safely and effectively deliver cell-based therapy for patients with single-tract fistulizing perianal Crohn’s disease. See Video Abstract at http://links.lww.com/DCR/C70. RESPUESTA DURADERA OBSERVADA EN PACIENTES CON ENFERMEDAD DE CROHN PERIANAL FISTULIZANTE REFRACTARIA MEDIANTE EL USO DE CÉLULAS MADRE MESENQUIMALES AUTÓLOGAS EN UNA MATRIZ DISOLUBLE: RESULTADOS DEL ENSAYO DE FASE I STEM CELL ON MATRIX PLUG ANTECEDENTES: La enfermedad de Crohn perianal refractaria sigue siendo notoriamente difícil de tratar. Desarrollamos una tecnología novedosa utilizando un tapón de fístula bioabsorbible disponible comercialmente para administrar células madre mesenquimales derivadas de tejido adiposo autólogo. OBJETIVO: Evaluar la seguridad y viabilidad terapéutica en el ensayo finalizado STOMP. DISEÑO: Ensayo clínico prospectivo de fase I de un solo brazo. AJUSTE: Centro médico académico terciario. PACIENTES: Adultos (18-65) con fístula perianal compleja de la enfermedad de Crohn de un solo tracto que han fracasado con la terapia convencional. INTERVENCIÓN: Se aislaron células madre mesenquimales derivadas de tejido adiposo autólogo, se expandieron en cultivo ex vivo y se sembraron en un tapón de fístula bioabsorbible disponible comercialmente. Seis semanas después, los pacientes regresaron al quirófano para retirar el setón y colocar el tapón cargado de células madre. PRINCIPALES MEDIDAS DE RESULTADO: Los pacientes fueron seguidos durante un total de 8 visitas durante 12 meses. La seguridad fue el criterio principal de valoración; la curación clínica y la respuesta a la resonancia magnética fueron criterios de valoración secundarios. RESULTADOS: Veinte pacientes (12 mujeres, edad media 36 años) fueron tratados con el tapón cargado de células madre. De los 20 pacientes inscritos, tres no se incluyeron en el análisis de 12 meses porque se retiraron del estudio. A lo largo de 12 meses, ningún paciente experimentó un evento adverso grave relacionado con el tapón cargado de células madre. Cuatro pacientes experimentaron 7 eventos adversos graves y 12 pacientes experimentaron 22 eventos adversos. La curación clínica completa ocurrió en 14 de 18 pacientes a los 6 meses y en 13 de 17 pacientes a los 12 meses. La respuesta a la resonancia magnética se observó en 12 de 18 pacientes a los 6 meses. LIMITACIONES: Las principales limitaciones son el tamaño pequeño de la muestra y los criterios de inclusión restrictivos. CONCLUSIONES: Un tapón cargado de células madre se puede administrar de manera segura y efectiva, una terapia basada en células para pacientes con enfermedad de Crohn perianal fistulizante de un solo tracto. Consule Video Resumen en http://links.lww.com/DCR/C70. (Traducción— Dr. Yesenia Rojas-Khalil)
Validation of stricture length, duration and obstructive symptoms as predictors for intervention in ileal stricturing Crohn's disease
AbstractBackgroundRisk factors for intervention in terminal ileal (TI) stricturing Crohn's disease (CD) are poorly defined. Novel and rigorous definitions for TI strictures recently became available.ObjectiveWe aimed to describe the rates of symptoms or need for endoscopic balloon dilation (EBD) or surgery as well as risk factors of progression in a well‐defined stricturing CD cohort.MethodsConsecutive adult patients with non‐penetrating stricturing TI CD, as defined by centrally‐read magnetic resonance enterography CONSTRICT criteria, were separated into a derivation and validation cohort. Clinical and imaging characteristics were collected following prespecified scoring conventions. Primary outcome was a composite endpoint of EBD or surgery (“intervention”). Multivariable analysis was performed.ResultsEighty‐six patients (48.8% female, median age 36 years) met selection criteria, 17.4% had prior EBD, 59.3% previously received biologics and 58.1% of strictures were anastomotic. Median follow‐up was 63.4 [95% CI: 57, 68.9] months. In the derivation cohort, at 12 and 48 months, 26% and 45% of patients had intervention, respectively. Multivariable analysis showed obstructive symptoms (Hazard ratio [HR] 1.444; 95% CI 1.126–1.852), stricture duration (HR 0.974; 95% CI, 0.954–0.995) and length (HR 1.039; 95% CI, 1.011–1.069) predicted intervention. The concordance index for split‐sample validation was 0.74 and 0.67, respectively. Biologics were not associated with intervention. An online risk calculator was constructed.ConclusionIn patients with TI stricturing CD, 26% and 45% required intervention at 1 and 4 years. Obstructive symptoms, stricture duration and length were independent and validated predictors of the need for intervention. These findings are important for clinical practice and aid in the design of future trials for CD strictures.
Photon-Counting Detector CT for Musculoskeletal Imaging: A Clinical Perspective