AbstractObjectivesTo examine the safety of utilizing transapical access during structural interventions.BackgroundComplex interventions of the mitral or aortic region sometimes require coaxial forces to orient and deliver devices. Apical access can provide coaxial countertraction for either transseptal or retrograde aortic access. This manuscript describes the single center experience of small bore transapical access.MethodsRetrospective review of cases from 2013 to 2018 at Henry Ford Hospital was performed. Patient demographics and procedure characteristics were abstracted to describe the safety of transapical access using small bore sheaths.ResultsA total 21 cases were performed at Henry Ford, most of them for transcatheter mitral valve replacement (81%). The mean sheath size used was 4.7 ± 0.9 Fr and protamine was used at the end of 57% of cases. All patients received nitinol‐based plugs, 80.1% were from the Amplatz Duct Occluder II type. Four major complications related apical puncture occurred, two pericardial effusions, two hemothorax. Over a median follow time of 430 days (IQR 50–652) a total of five deaths occurred, two related to the procedure and three late deaths with a median time of 362 days (range 205–628 days). No deaths were associated with transapical access. Echocardiographic follow up did not detect any late structural complications from occluder devices.ConclusionsTransapical access and closure with nitinol‐based devices is feasible and facilitates complex interventions where coaxial forces are need for device delivery and alignment. The most common complication is bleeding and this should be kept in perspective when treating high‐risk patients.
Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Percutaneous Vascular Closure Device
Background: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. Methods and Results: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). Conclusions: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.
Association of peripheral artery disease with in‐hospital outcomes after endovascular transcatheter aortic valve replacement
AbstractObjectivesThe aim of this study was to determine the prevalence of peripheral artery disease (PAD) and its association with in‐hospital outcomes after endovascular transcatheter aortic valve replacement (EV‐TAVR).BackgroundTAVR is an established treatment for patients at prohibitive, high, or intermediate surgical risk. PAD is a significant comorbidity in the determination of surgical risk. However, data on association of PAD with outcomes after EV‐TAVR are limited.MethodsPatients in the National Inpatient Sample who underwent EV‐TAVR between January 1, 2012 and September 30, 2015 were evaluated. The primary outcome was in‐hospital mortality.ResultsA total of 51,685 patients underwent EV‐TAVR during the study period. Of these, 12,740 (24.6%) had a coexisting diagnosis of PAD. The adjusted odds for in‐hospital mortality [OR 1.08 (95% CI 0.83–1.41)], permanent pacemaker implantation [OR 0.98 (0.85–1.14)], conversion to open aortic valve replacement [OR 1.05 (0.49–2.26)], or acute myocardial infarction [OR 1.31(0.99–1.71)] were not different in patients with versus without PAD. However, patients with PAD had greater adjusted odds of vascular complications [OR 1.80 (1.50–2.16)], major bleeding [OR 1.20 (1.09–1.34)], acute kidney injury (AKI) [OR 1.19 (1.05–1.36)], cardiac complications [aOR 1.21 (1.01–1.44)], and stroke [OR 1.39(1.10–1.75)] compared with patients without PAD. Length of stay (LOS) was significantly longer for patients with PAD [7.23 (0.14) days vs. 7.11 (0.1) days, p < 0.001].ConclusionOf patients undergoing EV‐TAVR, ~25% have coexisting PAD. PAD was not associated with increased risk of in‐hospital mortality but was associated with higher risk of vascular complications, major bleeding, AKI, stroke, cardiac complications, and longer LOS.
Influence of hospital volume on outcomes of percutaneous atrial septal defect and patent foramen ovale closure: A 10‐years us perspective