BACKGROUND AND OBJECTIVES: External ventricular drain (EVD) placement is the most commonly performed bedside emergent neurosurgical procedure. However, catheter misplacement occurs in approximately 25% of cases, potentially resulting in neurological injury or the need for repositioning, highlighting the need for safer and more accurate placement techniques. This review aims to (1) summarize technological innovations developed to enhance the accuracy and safety of bedside EVD placement, (2) evaluate their reported benefits and limitations, and (3) identify key barriers to their clinical implementation in critical care settings. METHODS: We conducted a systematic review of PubMed, Embase, and Scopus combining terms related to EVD placement and assistive technologies. All the studies evaluated EVD placement using simulations, phantoms, cadavers, and patient procedures conducted at the bedside and in the operating room. RESULTS: We identified 3898 records, and 76 studies met the inclusion criteria. Of these, 30 studies compared stereotactic systems, ultrasound guidance, frameless neuronavigation, and augmented or mixed reality technologies to the freehand technique. These studies consistently reported improved accuracy with advanced systems although complication rates and procedural times were variably reported. An additional 35 and 12 studies evaluated nonimmersive and immersive technologies, respectively, in noncomparative settings. Most of these demonstrated high first-pass success and mean tip deviations under 3 mm. Variability in the definitions of accuracy and procedural metrics limited data synthesis, but the overall findings suggest a promising trajectory for technology-assisted EVD placement. CONCLUSION: Assistive technologies for EVD placement show potential to improve accuracy and safety over the freehand technique. These early successes signal potential to improve bedside neurosurgical care. Realizing this promise will require future studies to standardize accuracy metrics, report time, and safety outcomes consistently and validate performance in real-world critical care settings.
Boron‐Doped Nano‐Crystalline Coated Carbon Fibers for Phasic Dopamine Sensing
ABSTRACT Real time, chronic electrochemical detection of neurotransmitters will provide a positive step in the treatment and understanding of neurological disease. However, current electrodes using carbon fibers (CF) fail to perform chronically. While diamond‐based coatings show promise in improving their longevity, achieving a uniform layer of such coatings on CFs is challenging, and the electrodes often lose sensitivity after coating. In this work, a complete and uniform boron‐doped nanocrystalline material grown in a diamond reactor (B‐NCD) was developed to coat CF microelectrodes for neurochemical sensing. The coating was characterized electrically, optically, mechanically, and chemically. The B‐NCD coated CF electrodes were able to detect phasic dopamine at a sensitivity comparable to the most widely used alternatives (uncoated and PEDOT:Nafion coated CFs). During biofouling testing, the B‐NCD coated CF electrodes demonstrated better stability than uncoated CFs and comparable performance to PEDOT:Nafion coated CFs. Moreover, B‐NCD exhibited no signs of degradation during consecutive FSCV applications, while uncoated and PEDOT:Nafion coated CF electrodes degraded significantly over time. Furthermore, the B‐NCD coating supported the survival and development of neurons and astrocytes in vitro, exhibited excellent adhesion and durability during mechanical bending testing, and enabled successful in vivo recording of phasic dopamine release in the rat brain. Overall, B‐NCD coated CFs present as an ideal candidate for chronic, flexible neural implantable electrodes for long‐term neurochemical monitoring.
High-Frequency Stimulation of the Ventral Tegmental Area Rescues Respiratory Failure
Abstract Introduction: Opioid use disorder constitutes a significant health crisis in the United States, contributing to high rates of opioid overdose-related deaths. A major driver of these fatalities is fentanyl, a potent synthetic opioid with both sedative and analgesic properties. These properties that make fentanyl clinically effective also increase its addictive potential. Early in opioid addiction, abnormal increases in extracellular dopamine in the nucleus accumbens (NAc) reinforce excessive drug-seeking behaviors which can lead to fatal respiratory depression. Given this mechanism, we investigated whether high frequency stimulation (HFS), mimicking human deep brain stimulation (DBS) of the ventral tegmental area (VTA) could block NAc dopamine increase following an acute lethal dose of fentanyl. We hypothesized that VTA DBS would mitigate these dopaminergic responses and prevent fentanyl-induced respiratory failure. Methods: Multiple cyclic square wave voltammetry (M-CSWV), was applied via a carbon fiber microelectrode in the NAc of urethane-anesthetized male Sprague-Dawley rats. Dopamine levels were recorded at baseline and following acute fentanyl (30 µg/kg, i.v.). HFS (130 Hz frequency, 200 µsec pulse width, and 0.2 mA amplitude) was administered to the VTA before and during fentanyl exposure. Results: Acute fentanyl administration resulted in a 178.2% increase in NAc dopamine levels from baseline, accompanied by a decline in respiratory rates to critically low levels (45 breaths per minute vs. 102 bpm), eventually resulting in 100% mortality. HFS of the VTA did not significantly alter baseline tonic dopamine levels or prevent fentanyl-induced dopamine increase in the NAc but was able to fully rescue fentanyl-induced respiratory failure.
Electrical Stimulation of the Anterior and Centromedian Nucleus of Thalamus for Treatment of Refractory Epilepsy _ Report of Four Cases (P7.279)
Abstract Electrical stimulation of the cerebral cortex (ESCC) has been used to treat intractable neuropathic pain for nearly two decades, however, no standardized approach for this technique has been developed. In order to optimize targeting and validate the effect of ESCC before placing the permanent grid, we introduced initial assessment with trial stimulation, using a temporary grid of subdural electrodes. In this retrospective study we evaluate the role of electrode location on cerebral cortex in control of neuropathic pain and the role of trial stimulation in target-optimization for ESCC. Location of the temporary grid electrodes and location of permanent electrodes were evaluated in correlation with the long-term efficacy of ESCC. The results of this study demonstrate that the long-term effect of subdural pre-motor cortex stimulation is at least the same or higher compare to effect of subdural motor or combined pre-motor and motor cortex stimulation. These results also demonstrate that the initial trial stimulation helps to optimize permanent electrode positions in relation to the optimal functional target that is critical in cases when brain shift is expected. Proposed methodology and novel results open a new direction for development of neuromodulation techniques to control chronic neuropathic pain.
Impact of long-term epidural electrical stimulation enabled task-specific training on secondary conditions of chronic paraplegia in two humans
Analysis of the induced stress on undoped and boron-doped diamond (BDD) thin films by confocal Raman microscopy is performed in this study to investigate its correlation with sample chemical composition and the substrate used during fabrication. Knowledge of this nature is very important to the issue of long-term stability of BDD coated neurosurgical electrodes that will be used in fast-scan cyclic voltammetry, as potential occurrence of film delaminations and dislocations during their surgical implantation can have unwanted consequences for the reliability of BDD-based biosensing electrodes. To achieve a more uniform deposition of the films on cylindrically-shaped tungsten rods, substrate rotation was employed in a custom-built chemical vapor deposition reactor. In addition to visibly preferential boron incorporation into the diamond lattice and columnar growth, the results also reveal a direct correlation between regions of pure diamond and enhanced stress. Definite stress release throughout entire film thicknesses was found in the current Raman mapping images for higher amounts of boron addition. There is also a possible contribution to the high values of compressive stress from sp2 type carbon impurities, besides that of the expected lattice mismatch between film and substrate.