ABSTRACT Real time, chronic electrochemical detection of neurotransmitters will provide a positive step in the treatment and understanding of neurological disease. However, current electrodes using carbon fibers (CF) fail to perform chronically. While diamond‐based coatings show promise in improving their longevity, achieving a uniform layer of such coatings on CFs is challenging, and the electrodes often lose sensitivity after coating. In this work, a complete and uniform boron‐doped nanocrystalline material grown in a diamond reactor (B‐NCD) was developed to coat CF microelectrodes for neurochemical sensing. The coating was characterized electrically, optically, mechanically, and chemically. The B‐NCD coated CF electrodes were able to detect phasic dopamine at a sensitivity comparable to the most widely used alternatives (uncoated and PEDOT:Nafion coated CFs). During biofouling testing, the B‐NCD coated CF electrodes demonstrated better stability than uncoated CFs and comparable performance to PEDOT:Nafion coated CFs. Moreover, B‐NCD exhibited no signs of degradation during consecutive FSCV applications, while uncoated and PEDOT:Nafion coated CF electrodes degraded significantly over time. Furthermore, the B‐NCD coating supported the survival and development of neurons and astrocytes in vitro, exhibited excellent adhesion and durability during mechanical bending testing, and enabled successful in vivo recording of phasic dopamine release in the rat brain. Overall, B‐NCD coated CFs present as an ideal candidate for chronic, flexible neural implantable electrodes for long‐term neurochemical monitoring.
Three-dimensional surface scanning for registration in stereotactic neurosurgery: a cadaveric feasibility study
OBJECTIVE Achieving submillimetric accuracy in stereotactic neurosurgery remains critical for safely targeting deep brain structures. Current workflows rely on intraoperative CT to register stereotactic frames to preoperative imaging, but this introduces additional radiation exposure, cost, and workflow complexity. Three-dimensional surface scanning (3DSS) potentially offers a fast radiation-free alternative capable of capturing detailed craniofacial anatomy and frame geometry. Therefore, the aim of this cadaveric study was to evaluate the feasibility, accuracy, and navigational compatibility of integrating 3DSS into stereotactic workflows as a potential replacement for intraoperative CT. METHODS A human cadaveric head was imaged with both thin-slice CT and structured-light 3DSS after mounting stereotactic frame components. CT, 3DSS, and computer-aided design (CAD) models were registered using a multistep point cloud alignment pipeline involving the fast point feature histogram, the random sample consensus method, and the iterative closest point algorithm. Accuracy was assessed using surface deviation error, root mean square error (RMSE), and fiducial registration error within a commercial neuronavigation platform. RESULTS Fusion of the 3D facial scan with CT provided a mean surface deviation error of approximately 0.4 mm. Registration of the 3DSS-derived N-bar localizer to its CAD reference model produced a frame alignment RMSE of 1.3 mm. Within the navigation system, the 3DSS-based workflow achieved a mean fiducial registration error of 0.14 mm (range 0.02–0.20 mm), outperforming the conventional CT-based method (mean error 0.20 mm, range 0.09–0.40 mm). CONCLUSIONS The 3DSS-based method enabled precise submillimetric stereotactic registration without the need for intraoperative CT, reducing radiation exposure and operative complexity. This workflow is fully compatible with existing navigation systems and could serve as a practical radiation-free alternative in stereotactic neurosurgery. Future work will focus on automating frame detection, incorporating artificial intelligence–driven fusion methods, and validating this approach in live surgical settings.
High-Frequency Stimulation of the Ventral Tegmental Area Rescues Respiratory Failure
Abstract Introduction: Opioid use disorder constitutes a significant health crisis in the United States, contributing to high rates of opioid overdose-related deaths. A major driver of these fatalities is fentanyl, a potent synthetic opioid with both sedative and analgesic properties. These properties that make fentanyl clinically effective also increase its addictive potential. Early in opioid addiction, abnormal increases in extracellular dopamine in the nucleus accumbens (NAc) reinforce excessive drug-seeking behaviors which can lead to fatal respiratory depression. Given this mechanism, we investigated whether high frequency stimulation (HFS), mimicking human deep brain stimulation (DBS) of the ventral tegmental area (VTA) could block NAc dopamine increase following an acute lethal dose of fentanyl. We hypothesized that VTA DBS would mitigate these dopaminergic responses and prevent fentanyl-induced respiratory failure. Methods: Multiple cyclic square wave voltammetry (M-CSWV), was applied via a carbon fiber microelectrode in the NAc of urethane-anesthetized male Sprague-Dawley rats. Dopamine levels were recorded at baseline and following acute fentanyl (30 µg/kg, i.v.). HFS (130 Hz frequency, 200 µsec pulse width, and 0.2 mA amplitude) was administered to the VTA before and during fentanyl exposure. Results: Acute fentanyl administration resulted in a 178.2% increase in NAc dopamine levels from baseline, accompanied by a decline in respiratory rates to critically low levels (45 breaths per minute vs. 102 bpm), eventually resulting in 100% mortality. HFS of the VTA did not significantly alter baseline tonic dopamine levels or prevent fentanyl-induced dopamine increase in the NAc but was able to fully rescue fentanyl-induced respiratory failure.
Toward Precise Modeling of Dopamine Release Kinetics: Comparison and Validation of Kinetic Models Using Voltammetry
Abstract Background Treatment of refractory bipolar disorder (BD) is extremely challenging. Deep brain stimulation (DBS) holds promise as an effective treatment intervention. However, we still understand very little about the mechanisms of DBS and its application on BD. Aim The present study aimed to investigate the behavioural and neurochemical effects of ventral tegmental area (VTA) DBS in an animal model of mania induced by methamphetamine (m‐amph). Methods Wistar rats were given 14 days of m‐amph injections, and on the last day, animals were submitted to 20 min of VTA DBS in two different patterns: intermittent low‐frequency stimulation (LFS) or continuous high‐frequency stimulation (HFS). Immediately after DBS, manic‐like behaviour and nucleus accumbens (NAc) phasic dopamine (DA) release were evaluated in different groups of animals through open‐field tests and fast‐scan cyclic voltammetry. Levels of NAc dopaminergic markers were evaluated by immunohistochemistry. Results M‐amph induced hyperlocomotion in the animals and both DBS parameters reversed this alteration. M‐amph increased DA reuptake time post‐sham compared to baseline levels, and both LFS and HFS were able to block this alteration. LFS was also able to reduce phasic DA release when compared to baseline. LFS was able to increase dopamine transporter (DAT) expression in the NAc. Conclusion These results demonstrate that both VTA LFS and HFS DBS exert anti‐manic effects and modulation of DA dynamics in the NAc. More specifically the increase in DA reuptake driven by increased DAT expression may serve as a potential mechanism by which VTA DBS exerts its anti‐manic effects.
Techniques for Measurement of Serotonin: Implications in Neuropsychiatric Disorders and Advances in Absolute Value Recording Methods
Abstract Tourette syndrome is a childhood-onset neuropsychiatric disorder characterized by intrusive motor and vocal tics that can lead to self-injury and deleterious mental health complications. While dysfunction in striatal dopamine neurotransmission has been proposed to underlie tic behaviour, evidence is scarce and inconclusive. Deep brain stimulation (DBS) of the thalamic centromedian parafascicular complex (CMPf), an approved surgical interventive treatment for medical refractory Tourette syndrome, may reduce tics by affecting striatal dopamine release. Here, we use electrophysiology, electrochemistry, optogenetics, pharmacological treatments and behavioural measurements to mechanistically examine how thalamic DBS modulates synaptic and tonic dopamine activity in the dorsomedial striatum. Previous studies demonstrated focal disruption of GABAergic transmission in the dorsolateral striatum of rats led to repetitive motor tics recapitulating the major symptom of Tourette syndrome. We employed this model under light anaesthesia and found CMPf DBS evoked synaptic dopamine release and elevated tonic dopamine levels via striatal cholinergic interneurons while concomitantly reducing motor tic behaviour. The improvement in tic behaviour was found to be mediated by D2 receptor activation as blocking this receptor prevented the therapeutic response. Our results demonstrate that release of striatal dopamine mediates the therapeutic effects of CMPf DBS and points to striatal dopamine dysfunction as a driver for motor tics in the pathoneurophysiology of Tourette syndrome.
Neurochemical Concentration Prediction Using Deep Learning vs Principal Component Regression in Fast Scan Cyclic Voltammetry: A Comparison Study
Serotonin plays a vital role in drug addiction. Here, using N-shaped fast-scan cyclic voltammetry, we demonstrated the effect of cocaine on the phasic release of serotonin at the nucleus accumbens core. To the best of our knowledge, this has not previously been elucidated. Our results not only reinforce the role of serotonin in the mechanism of action of cocaine but also help to fill a gap in our knowledge and provide a baseline for future studies in cocaine addiction.