Back to Authors

Blaha, Charles

0000-0001-5155-1505

Mayo Clinic

Mayo Clinic.

Citations 8

Boron‐Doped Nano‐Crystalline Coated Carbon Fibers for Phasic Dopamine Sensing
Higham, Simon , Cabrera, Juan M. Rojas , Kwak, Youngjong , Hong, Lydia, Chambers, Andre , Nadarajah, Athavan, León, Sorel E. De , Jung, Young Jun , Jalilinejad, Negin , Jang, Dong Pyo , Shin, Hojin , Tong, Wei , Higham, Simon J , Blaha, Charles , Lee, Kendall, Shin, Hojin , Tong, Wei , Rojas Cabrera, Juan M , Hong, Lydia, Blaha, Charles D. , Oh, Yoonbae , Lee, Kendall , Stacey, Alastair D. , Cloherty, Shaun Liam , Ibbotson, Michael R. , Garrett, David J. , Prawer, Steven

Advanced Healthcare Materials | December 18, 2025 | Volume: 15 | Issue: 15 | Pages: No page available

10.1002/adhm.202503945 Get It

ABSTRACT Real time, chronic electrochemical detection of neurotransmitters will provide a positive step in the treatment and understanding of neurological disease. However, current electrodes using carbon fibers (CF) fail to perform chronically. While diamond‐based coatings show promise in improving their longevity, achieving a uniform layer of such coatings on CFs is challenging, and the electrodes often lose sensitivity after coating. In this work, a complete and uniform boron‐doped nanocrystalline material grown in a diamond reactor (B‐NCD) was developed to coat CF microelectrodes for neurochemical sensing. The coating was characterized electrically, optically, mechanically, and chemically. The B‐NCD coated CF electrodes were able to detect phasic dopamine at a sensitivity comparable to the most widely used alternatives (uncoated and PEDOT:Nafion coated CFs). During biofouling testing, the B‐NCD coated CF electrodes demonstrated better stability than uncoated CFs and comparable performance to PEDOT:Nafion coated CFs. Moreover, B‐NCD exhibited no signs of degradation during consecutive FSCV applications, while uncoated and PEDOT:Nafion coated CF electrodes degraded significantly over time. Furthermore, the B‐NCD coating supported the survival and development of neurons and astrocytes in vitro, exhibited excellent adhesion and durability during mechanical bending testing, and enabled successful in vivo recording of phasic dopamine release in the rat brain. Overall, B‐NCD coated CFs present as an ideal candidate for chronic, flexible neural implantable electrodes for long‐term neurochemical monitoring.
High-Frequency Stimulation of the Ventral Tegmental Area Rescues Respiratory Failure
Shin, Hojin , Vettleson-Trutza, Sara A. , Cabrera, Juan Rojas, Kwak, Youngjong , Oesterle, Tyler , Blaha, Charles D. , Oh, Yoonbae , Lee, Kendall, Vettleson-Trutza, Sara , Scheitler, Kristen, Tsai, Sheng-Ta, Oesterle, Tyler S , Blaha, Charles , Oh, Yoonbae , Scheitler, Kristen M. , Tsai, Sheng-Ta , Sung, Jaeyun , Lee, Kendall H.

No container title available | June 23, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-6740056/v1 Get It

Abstract Introduction: Opioid use disorder constitutes a significant health crisis in the United States, contributing to high rates of opioid overdose-related deaths. A major driver of these fatalities is fentanyl, a potent synthetic opioid with both sedative and analgesic properties. These properties that make fentanyl clinically effective also increase its addictive potential. Early in opioid addiction, abnormal increases in extracellular dopamine in the nucleus accumbens (NAc) reinforce excessive drug-seeking behaviors which can lead to fatal respiratory depression. Given this mechanism, we investigated whether high frequency stimulation (HFS), mimicking human deep brain stimulation (DBS) of the ventral tegmental area (VTA) could block NAc dopamine increase following an acute lethal dose of fentanyl. We hypothesized that VTA DBS would mitigate these dopaminergic responses and prevent fentanyl-induced respiratory failure. Methods: Multiple cyclic square wave voltammetry (M-CSWV), was applied via a carbon fiber microelectrode in the NAc of urethane-anesthetized male Sprague-Dawley rats. Dopamine levels were recorded at baseline and following acute fentanyl (30 µg/kg, i.v.). HFS (130 Hz frequency, 200 µsec pulse width, and 0.2 mA amplitude) was administered to the VTA before and during fentanyl exposure. Results: Acute fentanyl administration resulted in a 178.2% increase in NAc dopamine levels from baseline, accompanied by a decline in respiratory rates to critically low levels (45 breaths per minute vs. 102 bpm), eventually resulting in 100% mortality. HFS of the VTA did not significantly alter baseline tonic dopamine levels or prevent fentanyl-induced dopamine increase in the NAc but was able to fully rescue fentanyl-induced respiratory failure.
Increased cortical extracellular adenosine correlates with seizure termination
Bower, Mark R. , Stead, Matt, Chang, Su‐Youne, Goerss, Stephan J., Kim, Inyong , Bennet, Kevin E. , Meyer, Fredric B. , Marsh, W. Richard , Blaha, Charles D. , Lee, Kendall H. , Van Gompel, Jamie J, Gompel, Jamie J. Van , Worrell, Gregory A. , Blaha, Charles

Epilepsia | January 31, 2014 | Volume: 55 | Issue: 2 | Pages: 233-244

10.1111/epi.12511 Get It

SummaryObjectiveSeizures are currently defined by their electrographic features. However, neuronal networks are intrinsically dependent on neurotransmitters of which little is known regarding their periictal dynamics. Evidence supports adenosine as having a prominent role in seizure termination, as its administration can terminate and reduce seizures in animal models. Furthermore, microdialysis studies in humans suggest that adenosine is elevated periictally, but the relationship to the seizure is obscured by its temporal measurement limitations. Because electrochemical techniques can provide vastly superior temporal resolution, we test the hypothesis that extracellular adenosine concentrations rise during seizure termination in an animal model and humans using electrochemistry.MethodsWhite farm swine (n = 45) were used in an acute cortical model of epilepsy, and 10 human epilepsy patients were studied during intraoperative electrocorticography (ECoG). Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS)–based fast scan cyclic voltammetry (FSCV) and fixed potential amperometry were obtained utilizing an adenosine‐specific triangular waveform or biosensors, respectively.ResultsSimultaneousECoG and electrochemistry demonstrated an average adenosine increase of 260% compared to baseline, at 7.5 ± 16.9 s with amperometry (n = 75 events) and 2.6 ± 11.2 s withFSCV(n = 15 events) prior to electrographic seizure termination. In agreement with these animal data, adenosine elevation prior to seizure termination in a human patient utilizingFSCVwas also seen.SignificanceSimultaneousECoG and electrochemical recording supports the hypothesis that adenosine rises prior to seizure termination, suggesting that adenosine itself may be responsible for seizure termination. Future work using intraoperativeWINCS–basedFSCVrecording may help to elucidate the precise relationship between adenosine and seizure termination.
Development of the Mayo Investigational Neuromodulation Control System: toward a closed-loop electrochemical feedback system for deep brain stimulation
Chang, Su-Youne , Kimble, Christopher J., Kim, Inyong , Paek, Seungleal, Kressin, Kenneth R., Boesche, Joshua B., Whitlock, Sidney V., Eaker, Diane R., Kasasbeh, Aimen, Horne, April E., Blaha, Charles D. , Bennet, Kevin E. , Lee, Kendall H. , Blaha, Charles

Journal of Neurosurgery | October 11, 2013 | Volume: 119 | Issue: 6 | Pages: 1556-1565

10.3171/2013.8.jns122142 Get It

Object Conventional deep brain stimulation (DBS) devices continue to rely on an open-loop system in which stimulation is independent of functional neural feedback. The authors previously proposed that as the foundation of a DBS “smart” device, a closed-loop system based on neurochemical feedback, may have the potential to improve therapeutic outcomes. Alterations in neurochemical release are thought to be linked to the clinical benefit of DBS, and fast-scan cyclic voltammetry (FSCV) has been shown to be effective for recording these evoked neurochemical changes. However, the combination of FSCV with conventional DBS devices interferes with the recording and identification of the evoked analytes. To integrate neurochemical recording with neurostimulation, the authors developed the Mayo Investigational Neuromodulation Control System (MINCS), a novel, wirelessly controlled stimulation device designed to interface with FSCV performed by their previously described Wireless Instantaneous Neurochemical Concentration Sensing System (WINCS). Methods To test the functionality of these integrated devices, various frequencies of electrical stimulation were applied by MINCS to the medial forebrain bundle of the anesthetized rat, and striatal dopamine release was recorded by WINCS. The parameters for FSCV in the present study consisted of a pyramidal voltage waveform applied to the carbon-fiber microelectrode every 100 msec, ramping between −0.4 V and +1.5 V with respect to an Ag/AgCl reference electrode at a scan rate of either 400 V/sec or 1000 V/sec. The carbon-fiber microelectrode was held at the baseline potential of −0.4 V between scans. Results By using MINCS in conjunction with WINCS coordinated through an optic fiber, the authors interleaved intervals of electrical stimulation with FSCV scans and thus obtained artifact-free wireless FSCV recordings. Electrical stimulation of the medial forebrain bundle in the anesthetized rat by MINCS elicited striatal dopamine release that was time-locked to stimulation and increased progressively with stimulation frequency. Conclusions Here, the authors report a series of proof-of-principle tests in the rat brain demonstrating MINCS to be a reliable and flexible stimulation device that, when used in conjunction with WINCS, performs wirelessly controlled stimulation concurrent with artifact-free neurochemical recording. These findings suggest that the integration of neurochemical recording with neurostimulation may be a useful first step toward the development of a closed-loop DBS system for human application.
Deep Brain Stimulation: Technology at the Cutting Edge
Shah, Rahul S. , Chang, Su-Youne , Min, Hoon‐Ki , Cho, Zang‐Hee , Blaha, Charles D. , Lee, Kendall H. , Min, Hoon-Ki Paul , Blaha, Charles

Journal of Clinical Neurology | January 20, 2011 | Volume: 6 | Issue: 4 | Pages: 167

10.3988/jcn.2010.6.4.167 Get It

Comonitoring of adenosine and dopamine using the Wireless Instantaneous Neurotransmitter Concentration System: proof of principle
Chang, Su-Youne , Tye, Susannah J. , Kimble, Christopher J., Bennet, Kevin E. , Blaha, Charles D. , Lee, Kendall H. , Shon, Young‐Min , Tye, Susannah J , Blaha, Charles

Journal of Neurosurgery | September 4, 2009 | Volume: 112 | Issue: 3 | Pages: 539-548

10.3171/2009.7.jns09787 Get It

Object The authors of previous studies have demonstrated that local adenosine efflux may contribute to the therapeutic mechanism of action of thalamic deep brain stimulation (DBS) for essential tremor. Real-time monitoring of the neurochemical output of DBS-targeted regions may thus advance functional neurosurgical procedures by identifying candidate neurotransmitters and neuromodulators involved in the physiological effects of DBS. This would in turn permit the development of a method of chemically guided placement of DBS electrodes in vivo. Designed in compliance with FDA-recognized standards for medical electrical device safety, the authors report on the utility of the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for real-time comonitoring of electrical stimulation–evoked adenosine and dopamine efflux in vivo, utilizing fast-scan cyclic voltammetry (FSCV) at a polyacrylonitrile-based (T-650) carbon fiber microelectrode (CFM). Methods The WINCS was used for FSCV, which consisted of a triangle wave scanned between −0.4 and +1.5 V at a rate of 400 V/second and applied at 10 Hz. All voltages applied to the CFM were with respect to an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single T-650 carbon fiber (r = 2.5 μm) into a glass capillary and pulling to a microscopic tip using a pipette puller. The exposed carbon fiber (the sensing region) extended beyond the glass insulation by ~ 50 μm. Proof of principle tests included in vitro measurements of adenosine and dopamine, as well as in vivo measurements in urethane-anesthetized rats by monitoring adenosine and dopamine efflux in the dorsomedial caudate putamen evoked by high-frequency electrical stimulation of the ventral tegmental area and substantia nigra. Results The WINCS provided reliable, high-fidelity measurements of adenosine efflux. Peak oxidative currents appeared at +1.5 V and at +1.0 V for adenosine, separate from the peak oxidative current at +0.6 V for dopamine. The WINCS detected subsecond adenosine and dopamine efflux in the caudate putamen at an implanted CFM during high-frequency stimulation of the ventral tegmental area and substantia nigra. Both in vitro and in vivo testing demonstrated that WINCS can detect adenosine in the presence of other easily oxidizable neurochemicals such as dopamine comparable to the detection abilities of a conventional hardwired electrochemical system for FSCV. Conclusions Altogether, these results demonstrate that WINCS is well suited for wireless monitoring of high-frequency stimulation-evoked changes in brain extracellular concentrations of adenosine. Clinical applications of selective adenosine measurements may prove important to the future development of DBS technology.
Wireless Instantaneous Neurotransmitter Concentration System–based amperometric detection of dopamine, adenosine, and glutamate for intraoperative neurochemical monitoring
Agnesi, Filippo , Tye, Susannah J. , Bledsoe, Jonathan M., Griessenauer, Christoph J. , Kimble, Christopher J., Sieck, Gary C. , Bennet, Kevin E. , Garris, Paul A. , Blaha, Charles D. , Lee, Kendall H. , Sieck, Gary , Tye, Susannah J , Griessenauer, Christoph J , Blaha, Charles

Journal of Neurosurgery | May 8, 2009 | Volume: 111 | Issue: 4 | Pages: 701-711

10.3171/2009.3.jns0990 Get It

Object In a companion study, the authors describe the development of a new instrument named the Wireless Instantaneous Neurotransmitter Concentration System (WINCS), which couples digital telemetry with fast-scan cyclic voltammetry (FSCV) to measure extracellular concentrations of dopamine. In the present study, the authors describe the extended capability of the WINCS to use fixed potential amperometry (FPA) to measure extracellular concentrations of dopamine, as well as glutamate and adenosine. Compared with other electrochemical techniques such as FSCV or high-speed chronoamperometry, FPA offers superior temporal resolution and, in combination with enzyme-linked biosensors, the potential to monitor nonelectroactive analytes in real time. Methods The WINCS design incorporated a transimpedance amplifier with associated analog circuitry for FPA; a microprocessor; a Bluetooth transceiver; and a single, battery-powered, multilayer, printed circuit board. The WINCS was tested with 3 distinct recording electrodes: 1) a carbon-fiber microelectrode (CFM) to measure dopamine; 2) a glutamate oxidase enzyme–linked electrode to measure glutamate; and 3) a multiple enzyme–linked electrode (adenosine deaminase, nucleoside phosphorylase, and xanthine oxidase) to measure adenosine. Proof-of-principle analyses included noise assessments and in vitro and in vivo measurements that were compared with similar analyses by using a commercial hardwired electrochemical system (EA161 Picostat, eDAQ; Pty Ltd). In urethane-anesthetized rats, dopamine release was monitored in the striatum following deep brain stimulation (DBS) of ascending dopaminergic fibers in the medial forebrain bundle (MFB). In separate rat experiments, DBS-evoked adenosine release was monitored in the ventrolateral thalamus. To test the WINCS in an operating room setting resembling human neurosurgery, cortical glutamate release in response to motor cortex stimulation (MCS) was monitored using a large-mammal animal model, the pig. Results The WINCS, which is designed in compliance with FDA-recognized consensus standards for medical electrical device safety, successfully measured dopamine, glutamate, and adenosine, both in vitro and in vivo. The WINCS detected striatal dopamine release at the implanted CFM during DBS of the MFB. The DBS-evoked adenosine release in the rat thalamus and MCS-evoked glutamate release in the pig cortex were also successfully measured. Overall, in vitro and in vivo testing demonstrated signals comparable to a commercial hardwired electrochemical system for FPA. Conclusions By incorporating FPA, the chemical repertoire of WINCS-measurable neurotransmitters is expanded to include glutamate and other nonelectroactive species for which the evolving field of enzyme-linked biosensors exists. Because many neurotransmitters are not electrochemically active, FPA in combination with enzyme-linked microelectrodes represents a powerful intraoperative tool for rapid and selective neurochemical sampling in important anatomical targets during functional neurosurgery.
Development of the Wireless Instantaneous Neurotransmitter Concentration System for intraoperative neurochemical monitoring using fast-scan cyclic voltammetry
Bledsoe, Jonathan M., Kimble, Christopher J., Covey, Daniel P., Blaha, Charles D. , Agnesi, Filippo , Mohseni, Pedram , Whitlock, Sidney V., Johnson, David , Horne, April E., Bennet, Kevin E. , Lee, Kendall H. , Garris, Paul A. , Covey, Dan P. , Blaha, Charles

Journal of Neurosurgery | May 8, 2009 | Volume: 111 | Issue: 4 | Pages: 712-723

10.3171/2009.3.jns081348 Get It

Object Emerging evidence supports the hypothesis that modulation of specific central neuronal systems contributes to the clinical efficacy of deep brain stimulation (DBS) and motor cortex stimulation (MCS). Real-time monitoring of the neurochemical output of targeted regions may therefore advance functional neurosurgery by, among other goals, providing a strategy for investigation of mechanisms, identification of new candidate neurotransmitters, and chemically guided placement of the stimulating electrode. The authors report the development of a device called the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for intraoperative neurochemical monitoring during functional neurosurgery. This device supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially and chemically resolved neurotransmitter measurements in the brain. Methods The FSCV study consisted of a triangle wave scanned between −0.4 and 1 V at a rate of 300 V/second and applied at 10 Hz. All voltages were compared with an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single carbon fiber (r = 2.5 μm) into a glass capillary and pulling the capillary to a microscopic tip by using a pipette puller. The exposed carbon fiber (that is, the sensing region) extended beyond the glass insulation by ~ 100 μm. The neurotransmitter dopamine was selected as the analyte for most trials. Proof-of-principle tests included in vitro flow injection and noise analysis, and in vivo measurements in urethane-anesthetized rats by monitoring dopamine release in the striatum following high-frequency electrical stimulation of the medial forebrain bundle. Direct comparisons were made to a conventional hardwired system. Results The WINCS, designed in compliance with FDA-recognized consensus standards for medical electrical device safety, consisted of 4 modules: 1) front-end analog circuit for FSCV (that is, current-to-voltage transducer); 2) Bluetooth transceiver; 3) microprocessor; and 4) direct-current battery. A Windows-XP laptop computer running custom software and equipped with a Universal Serial Bus–connected Bluetooth transceiver served as the base station. Computer software directed wireless data acquisition at 100 kilosamples/second and remote control of FSCV operation and adjustable waveform parameters. The WINCS provided reliable, high-fidelity measurements of dopamine and other neurochemicals such as serotonin, norepinephrine, and ascorbic acid by using FSCV at CFM and by flow injection analysis. In rats, the WINCS detected subsecond striatal dopamine release at the implanted sensor during high-frequency stimulation of ascending dopaminergic fibers. Overall, in vitro and in vivo testing demonstrated comparable signals to a conventional hardwired electrochemical system for FSCV. Importantly, the WINCS reduced susceptibility to electromagnetic noise typically found in an operating room setting. Conclusions Taken together, these results demonstrate that the WINCS is well suited for intraoperative neurochemical monitoring. It is anticipated that neurotransmitter measurements at an implanted chemical sensor will prove useful for advancing functional neurosurgery.