Back to Authors

Goerss, Stephan J.

Mayo Clinic

Mayo Clinic

Citations 6

A novel re-attachable stereotactic frame for MRI-guided neuronavigation and its validation in a large animal and human cadaver model
Edwards, Christine A. , Rusheen, Aaron E. , Paek, Seungleal, Lee, Kristen H, Dennis, Kendall D. , Bennet, Kevin E. , Kouzani, Abbas Z. , Lee, Kendall H. , Goerss, Stephan J., Paek, Seungleal B, Kouzani, Abbas Z , Oh, Yoonbae , Jacobs, Joshua J.

Journal of Neural Engineering | August 20, 2018 | Volume: 15 | Issue: 6 | Pages: 066003

10.1088/1741-2552/aadb49 Get It

Abstract Objective . Stereotactic frame systems are the gold-standard for stereotactic surgeries, such as implantation of deep brain stimulation (DBS) devices for treatment of medically resistant neurologic and psychiatric disorders. However, frame-based systems require that the patient is awake with a stereotactic frame affixed to their head for the duration of the surgical planning and implantation of the DBS electrodes. While frameless systems are increasingly available, a reusable re-attachable frame system provides unique benefits. As such, we created a novel reusable MRI-compatible stereotactic frame system that maintains clinical accuracy through the detachment and reattachment of its stereotactic devices used for MRI-guided neuronavigation. Approach . We designed a reusable arc-centered frame system that includes MRI-compatible anchoring skull screws for detachment and re-attachment of its stereotactic devices. We validated the stability and accuracy of our system through phantom, in vivo mock-human porcine DBS-model and human cadaver testing. Main results . Phantom testing achieved a root mean square error (RMSE) of 0.94 ± 0.23 mm between the ground truth and the frame-targeted coordinates; and achieved an RMSE of 1.11 ± 0.40 mm and 1.33 ± 0.38 mm between the ground truth and the CT- and MRI-targeted coordinates, respectively. In vivo and cadaver testing achieved a combined 3D Euclidean localization error of 1.85 ± 0.36 mm ( p < 0.03) between the pre-operative MRI-guided placement and the post-operative CT-guided confirmation of the DBS electrode. Significance . Our system demonstrated consistent clinical accuracy that is comparable to conventional frame and frameless stereotactic systems. Our frame system is the first to demonstrate accurate relocation of stereotactic frame devices during in vivo MRI-guided DBS surgical procedures. As such, this reusable and re-attachable MRI-compatible system is expected to enable more complex, chronic neuromodulation experiments, and lead to a clinically available re-attachable frame that is expected to decrease patient discomfort and costs of DBS surgery.
MRI-Guided Stereotactic System for Delivery of Intraspinal Microstimulation
Grahn, Peter J. , Goerss, Stephan J., Mallory, Grant W., Kall, Bruce A., Mendez, Aldo A. , Trevathan, James K. , Felmlee, Joel P. , Bennet, Kevin E. , Lee, Kendall H. , Luján, J. Luis , Trevathan, James K

Spine | December 16, 2015 | Volume: 41 | Issue: 13 | Pages: E806-E813

10.1097/brs.0000000000001397 Get It

Study Design. Laboratory/animal-based proof of principle study. Objective. To validate the accuracy of a magnetic resonance imaging (MRI)-guided stereotactic system for intraspinal electrode targeting and demonstrate the feasibility of such a system for controlling implantation of intraspinal electrodes. Summary of Background Data. Intraspinal microstimulation (ISMS) is an emerging preclinical therapy, which has shown promise for the restoration of motor function following spinal cord injury. However, targeting inaccuracy associated with existing electrode implantation techniques remains a major barrier preventing clinical translation of ISMS. Methods. System accuracy was evaluated using a test phantom comprised of nine target locations. Targeting accuracy was determined by calculating the root mean square error between MRI-generated coordinates and actual frame coordinates required to reach the target positions. System performance was further validated in an anesthetized pig model by performing MRI-guided intraspinal electrode implantation and stimulation followed by computed tomography of electrode location. Finally, system compatibility with a commercially available microelectrode array was demonstrated by implanting the array and applying a selection of stimulation amplitudes that evoked hind limb responses. Results. The root mean square error between actual frame coordinates and software coordinates, both acquired using the test phantom, was 1.09 ± 0.20 mm. Postoperative computed tomography in the anesthetized pig confirmed spatially accurate electrode placement relative to preoperative MRI. Additionally, MRI-guided delivery of a microwire electrode followed by ISMS evoked repeatable electromyography responses in the biceps femoris muscle. Finally, delivery of a microelectrode array produced repeatable and graded hind limb evoked movements. Conclusion. We present a novel frame-based stereotactic system for targeting and delivery of intraspinal instrumentation. This system utilizes MRI guidance to account for variations in anatomy between subjects, thereby improving upon existing ISMS electrode implantation techniques. Level of Evidence: N/A
Increased cortical extracellular adenosine correlates with seizure termination
Bower, Mark R. , Stead, Matt, Chang, Su‐Youne, Goerss, Stephan J., Kim, Inyong , Bennet, Kevin E. , Meyer, Fredric B. , Marsh, W. Richard , Blaha, Charles D. , Lee, Kendall H. , Van Gompel, Jamie J, Gompel, Jamie J. Van , Worrell, Gregory A. , Blaha, Charles

Epilepsia | January 31, 2014 | Volume: 55 | Issue: 2 | Pages: 233-244

10.1111/epi.12511 Get It

SummaryObjectiveSeizures are currently defined by their electrographic features. However, neuronal networks are intrinsically dependent on neurotransmitters of which little is known regarding their periictal dynamics. Evidence supports adenosine as having a prominent role in seizure termination, as its administration can terminate and reduce seizures in animal models. Furthermore, microdialysis studies in humans suggest that adenosine is elevated periictally, but the relationship to the seizure is obscured by its temporal measurement limitations. Because electrochemical techniques can provide vastly superior temporal resolution, we test the hypothesis that extracellular adenosine concentrations rise during seizure termination in an animal model and humans using electrochemistry.MethodsWhite farm swine (n = 45) were used in an acute cortical model of epilepsy, and 10 human epilepsy patients were studied during intraoperative electrocorticography (ECoG). Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS)–based fast scan cyclic voltammetry (FSCV) and fixed potential amperometry were obtained utilizing an adenosine‐specific triangular waveform or biosensors, respectively.ResultsSimultaneousECoG and electrochemistry demonstrated an average adenosine increase of 260% compared to baseline, at 7.5 ± 16.9 s with amperometry (n = 75 events) and 2.6 ± 11.2 s withFSCV(n = 15 events) prior to electrographic seizure termination. In agreement with these animal data, adenosine elevation prior to seizure termination in a human patient utilizingFSCVwas also seen.SignificanceSimultaneousECoG and electrochemical recording supports the hypothesis that adenosine rises prior to seizure termination, suggesting that adenosine itself may be responsible for seizure termination. Future work using intraoperativeWINCS–basedFSCVrecording may help to elucidate the precise relationship between adenosine and seizure termination.
Development of intraoperative electrochemical detection: wireless instantaneous neurochemical concentration sensor for deep brain stimulation feedback
Chang, Su-Youne , Goerss, Stephan J., Kimble, Christopher J., Bennet, Kevin E. , Lee, Kendall H. , Gompel, Jamie J. Van , Kim, In

Neurosurgical Focus | July 30, 2010 | Volume: 29 | Issue: 2 | Pages: E6

10.3171/2010.5.focus10110 Get It

Deep brain stimulation (DBS) is effective when there appears to be a distortion in the complex neurochemical circuitry of the brain. Currently, the mechanism of DBS is incompletely understood; however, it has been hypothesized that DBS evokes release of neurochemicals. Well-established chemical detection systems such as microdialysis and mass spectrometry are impractical if one is assessing changes that are happening on a second-to-second time scale or for chronically used implanted recordings, as would be required for DBS feedback. Electrochemical detection techniques such as fast-scan cyclic voltammetry (FSCV) and amperometry have until recently remained in the realm of basic science; however, it is enticing to apply these powerful recording technologies to clinical and translational applications. The Wireless Instantaneous Neurochemical Concentration Sensor (WINCS) currently is a research device designed for human use capable of in vivo FSCV and amperometry, sampling at subsecond time resolution. In this paper, the authors review recent advances in this electrochemical application to DBS technologies. The WINCS can detect dopamine, adenosine, and serotonin by FSCV. For example, FSCV is capable of detecting dopamine in the caudate evoked by stimulation of the subthalamic nucleus/substantia nigra in pig and rat models of DBS. It is further capable of detecting dopamine by amperometry and, when used with enzyme linked sensors, both glutamate and adenosine. In conclusion, WINCS is a highly versatile instrument that allows near real-time (millisecond) detection of neurochemicals important to DBS research. In the future, the neurochemical changes detected using WINCS may be important as surrogate markers for proper DBS placement as well as the sensor component for a “smart” DBS system with electrochemical feedback that allows automatic modulation of stimulation parameters. Current work is under way to establish WINCS use in humans.
Computed Tomography-based Stereotactic Third Ventriculostomy: Technical Note
Goerss, Stephan J., Kall, Bruce A., Kispert, David B., Kelly, Patrick J.

Neurosurgery | May 30, 2010 | Volume: 18 | Issue: 6 | Pages: 791-794

10.1227/00006123-198606000-00021 Get It

Abstract This report describes a computed tomography-based computer-assisted stereotactic technique for performing 3rd ventriculostomy. The procedure has been performed on seven patients with acquired obstructive hydrocephalus of various etiologies. None of these patients have yet required shunting. (18:791–794, 1986)
Methodology and Clinical Experience with Computed Tomography and a Computer-resident Stereotactic Atlas
Kall, Bruce A., Goerss, Stephan J., Frieder, Gideon, Kelly, Patrick J.

Neurosurgery | May 30, 2010 | Volume: 17 | Issue: 3 | Pages: 400-406

10.1227/00006123-198509000-00002 Get It

Abstract We have developed a computer-resident stereotactic atlas of the human brain that quantitatively defines subcortical structures within anatomical landmarks detected on obliquely reconstructed computed tomography (CT) slices. Horizontal stereotactic atlas sections can be stretched and contracted by polar transformation and labeled by a computer to fit within these CT scan-defined landmarks. The stereotactic coordinates of any substructure on the atlas-labeled CT slice may then be calculated by the computer and expressed in mechanical adjustments on a stereotactic surgical frame located in the operating room. We demonsrate the use of this method in the stereotactic treatment of movement disorders as an augmentation to conventional ventriculography and microelectrode recording.