Back to Authors

Kouzani, Abbas Z

0000-0002-6292-1214

Mayo Clinic

School of Engineering, Deakin University, Waurn Ponds, VIC 3216, Australia. abbas.kouzani@deakin.edu.au.

Citations 4

An Investigation Into Miniaturised Closed-Loop DBS Devices
Corva, Dean M. , Adams, Scott , Bennet, Kevin E. , Berk, Michael , Kouzani, Abbas Z. , Kouzani, Abbas Z , Berk, Michael , Hashemi, Parastoo

IEEE Transactions on Medical Robotics and Bionics | July 7, 2021 | Volume: 3 | Issue: 3 | Pages: 671-680

10.1109/tmrb.2021.3095361 Get It

Analysis of Carbon-Based Microelectrodes for Neurochemical Sensing
Manciu, Felicia , Barath, Abhijeet S. , Rusheen, Aaron E. , Kouzani, Abbas Z. , Hodges, Deidra , Guerrero, Jose, Tomshine, Jonathan R. , Lee, Kendall H. , Bennet, Kevin E. , Barath, Abhijeet, Rusheen, Aaron E , Kouzani, Abbas Z , Tomshine, Jonathan, Manciu, Felicia S , Oh, Yoonbae

Materials | September 30, 2019 | Volume: 12 | Issue: 19 | Pages: 3186

10.3390/ma12193186 Get It

The comprehensive microscopic, spectroscopic, and in vitro voltammetric analysis presented in this work, which builds on the well-studied properties of carbon-based materials, facilitates potential ways for improvement of carbon fiber microelectrodes (CFMs) for neuroscience applications. Investigations by both, scanning electron microscopy (SEM) and confocal Raman spectroscopy, confirm a higher degree of structural ordering for the fibers exposed to carbonization temperatures. An evident correlation is also identified between the extent of structural defects observed from SEM and Raman results with the CFM electrochemical performance for dopamine detection. To improve CFM physico-chemical surface stability and increase its mechanical resistance to the induced compressive stress during anticipated in vivo tissue penetration, successful coating of the carbon fiber with boron-doped diamond (BDD) is also performed and microspectroscopically analyzed here. The absence of spectral shifts of the diamond Raman vibrational signature verifies that the growth of an unstrained BDD thin film was achieved. Although more work needs to be done to identify optimal parameter values for improved BDD deposition, this study serves as a demonstration of foundational technology for the development of more sensitive electrochemical sensors, that may have been impractical previously for clinical applications, due to limitations in either safety or performance.
A novel re-attachable stereotactic frame for MRI-guided neuronavigation and its validation in a large animal and human cadaver model
Edwards, Christine A. , Rusheen, Aaron E. , Paek, Seungleal, Lee, Kristen H, Dennis, Kendall D. , Bennet, Kevin E. , Kouzani, Abbas Z. , Lee, Kendall H. , Goerss, Stephan J., Paek, Seungleal B, Kouzani, Abbas Z , Oh, Yoonbae , Jacobs, Joshua J.

Journal of Neural Engineering | August 20, 2018 | Volume: 15 | Issue: 6 | Pages: 066003

10.1088/1741-2552/aadb49 Get It

Abstract Objective . Stereotactic frame systems are the gold-standard for stereotactic surgeries, such as implantation of deep brain stimulation (DBS) devices for treatment of medically resistant neurologic and psychiatric disorders. However, frame-based systems require that the patient is awake with a stereotactic frame affixed to their head for the duration of the surgical planning and implantation of the DBS electrodes. While frameless systems are increasingly available, a reusable re-attachable frame system provides unique benefits. As such, we created a novel reusable MRI-compatible stereotactic frame system that maintains clinical accuracy through the detachment and reattachment of its stereotactic devices used for MRI-guided neuronavigation. Approach . We designed a reusable arc-centered frame system that includes MRI-compatible anchoring skull screws for detachment and re-attachment of its stereotactic devices. We validated the stability and accuracy of our system through phantom, in vivo mock-human porcine DBS-model and human cadaver testing. Main results . Phantom testing achieved a root mean square error (RMSE) of 0.94 ± 0.23 mm between the ground truth and the frame-targeted coordinates; and achieved an RMSE of 1.11 ± 0.40 mm and 1.33 ± 0.38 mm between the ground truth and the CT- and MRI-targeted coordinates, respectively. In vivo and cadaver testing achieved a combined 3D Euclidean localization error of 1.85 ± 0.36 mm ( p < 0.03) between the pre-operative MRI-guided placement and the post-operative CT-guided confirmation of the DBS electrode. Significance . Our system demonstrated consistent clinical accuracy that is comparable to conventional frame and frameless stereotactic systems. Our frame system is the first to demonstrate accurate relocation of stereotactic frame devices during in vivo MRI-guided DBS surgical procedures. As such, this reusable and re-attachable MRI-compatible system is expected to enable more complex, chronic neuromodulation experiments, and lead to a clinically available re-attachable frame that is expected to decrease patient discomfort and costs of DBS surgery.
Raman Microscopic Analysis of Internal Stress in Boron-Doped Diamond
Bennet, Kevin E. , Lee, Kendall, Tomshine, Jonathan R. , Sundin, Emma , Kruchowski, James, Durrer, William, Manciu, Bianca, Kouzani, Abbas Z. , Manciu, Felicia , Lee, Kendall H. , Kouzani, Abbas Z , Manciu, Felicia S

Materials | May 26, 2015 | Volume: 8 | Issue: 5 | Pages: 2782-2793

10.3390/ma8052782 Get It

Analysis of the induced stress on undoped and boron-doped diamond (BDD) thin films by confocal Raman microscopy is performed in this study to investigate its correlation with sample chemical composition and the substrate used during fabrication. Knowledge of this nature is very important to the issue of long-term stability of BDD coated neurosurgical electrodes that will be used in fast-scan cyclic voltammetry, as potential occurrence of film delaminations and dislocations during their surgical implantation can have unwanted consequences for the reliability of BDD-based biosensing electrodes. To achieve a more uniform deposition of the films on cylindrically-shaped tungsten rods, substrate rotation was employed in a custom-built chemical vapor deposition reactor. In addition to visibly preferential boron incorporation into the diamond lattice and columnar growth, the results also reveal a direct correlation between regions of pure diamond and enhanced stress. Definite stress release throughout entire film thicknesses was found in the current Raman mapping images for higher amounts of boron addition. There is also a possible contribution to the high values of compressive stress from sp2 type carbon impurities, besides that of the expected lattice mismatch between film and substrate.