AimsCeramic-on-ceramic (CoC) articulations in total hip arthroplasty (THA) have the advantage of low wear but the unique risk of fracture. After revision for CoC-bearing fracture, third-body ceramic particles can lead to massive wear of cobalt-chrome (CoCr) bearings, causing extremely elevated blood cobalt. We present a multicentre series of five cases where patients sustained fractures of ceramic liners, were revised using a CoCr articulation, and rapidly developed severe cobalt toxicity.MethodsWe identified five cases of cobalt toxicity after fractured CoC THA treated with revision to CoCr on polyethylene bearings. Mean follow-up was three years (5 to 72 months) after re-revision to remove the CoCr bearing.ResultsSymptoms of cobalt toxicity occurred at a mean ten months (6 to 12) after revision for ceramic fracture. All patients developed vision and hearing loss, balance difficulties, and peripheral neuropathy. Several had cardiomyopathy, endocrine abnormalities, and local skin discolouration. Only two reported hip pain. Repeat revision for recognized cobalt toxicity occurred at a mean 22 months after revision for ceramic fracture. Mean serum cobalt level at re-revision was 991 ng/ml (normal value < 1 ng/ml; 734 to 1,302). All CoCr femoral heads exhibited massive wear, and deep tissues showed prominent metal staining. Treatment consisted of debridement and revision to a ceramic femoral head with highly cross-linked polyethylene (HXLPE) liner. Serum cobalt improved to a mean 25 μg/l (1 to 76) at final follow-up. All patients reported partial improvement in vision and hearing, however their peripheral neuropathy and balance difficulties did not recover.ConclusionSystemic cobalt toxicity is a devastating complication of ceramic-bearing fracture in THA treated with CoCr bearings, which may not present with hip symptoms. The diagnosis of this syndrome of systemic cobalt toxicity was significantly delayed following systemic symptoms in this series. Debridement and re-revision to a ceramic-on-HXLPE bearing leads to improvement, but not full resolution, of cobalt toxicity complications.Cite this article: Bone Joint J 2025;107-B(6 Supple B):92–100.
Abstract: Adverse local tissue reactions (ALTRs) were initially reported as complications associated with metal-on-metal (MoM) bearings; however, there is increasing concern regarding the occurrence of adverse local tissue reactions from mechanically assisted crevice corrosion (MACC) at the femoral head-neck junction or between other modular junctions of the implant containing cobalt chromium parts in patients with metal-on-polyethylene (MoP) bearings. ALTR due to MACC at the head-neck junction has primarily been reported in association with cobalt chromium alloy femoral heads. As pain following total hip arthroplasty may have various intrinsic and extrinsic causes, a systematic approach to evaluation (risk stratification algorithm) based on the currently available data is recommended to optimize patient management. Evaluation should begin by ruling out common causes of pain, including component loosening and periprosthetic joint infection. While specialized tests such as blood metal analysis and metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful modalities in evaluating for ALTRs, over-reliance on any single investigative tool in the clinical decision-making process should be avoided. There should be a low threshold to perform a systematic evaluation for ALTR due to MACC in patients with metal-on-polyethylene total hip arthroplasty as early recognition and diagnosis is critical, as delays in appropriate treatment initiation may result in soft-tissue damage, which complicates surgical treatment and is associated with a higher risk of complications and poorer patient outcomes.
Abstract Glioblastoma (GBM) is a common deadly malignant brain cancer of the central nervous system (CNS), with a median survival of 12–15 months. Scientific advancements are lacking in developing effective therapies for both primary GBM, as well as secondary GBMs, that typically originate as malignant transformation of lower-grade isocitrate dehydrogenase (IDH) 1-mutant tumors. The unique metabolomic profile of IDH1-mutant tumors may present opportunities to develop biomarker signatures of therapeutic efficacy. Microdialysis is an extracellular fluid sampling collection technique utilizing a perfused semipermeable catheter to permit diffusion of molecules between brain interstitium and the perfusate. We hypothesized that microdialysis may identify a metabolomics-based biomarker response to therapy in IDH1-mutant tumors. To test this hypothesis, orthotopic xenografts were generated from two patient-derived GBM lines harboring mutations in IDH1. Perfusates were collected from intra-cranial tumors in aythmic nude mice sampled at baseline and 72h post treatment with temozolomide, an oral alkylating agent used to treat IDH1-mutant gliomas, compared with vehicle treatment, and TMZ-treated non-tumor bearing animals. Perfusates were analyzed via unsupervised metabolomic profiling using both gas and liquid chromatography-mass spectrometry (GC/LC-MS). Tumor specific metabolites such as carnitine and pyruvic acid were detected in microdialysate from tumor bearing mice compared to non-tumor bearing mice. Microdialysis is a feasible technology to identify metabolomics-based biomarker in IDH1-mutant PDX. This work is complemented by parallel analysis of non-IDH1-mutant and TMZ resistant xenografts to yield predictive in vivo tissue biomarkers of drug responsiveness translatable to clinical practice.
A novel re-attachable stereotactic frame for MRI-guided neuronavigation and its validation in a large animal and human cadaver model
Abstract Objective . Stereotactic frame systems are the gold-standard for stereotactic surgeries, such as implantation of deep brain stimulation (DBS) devices for treatment of medically resistant neurologic and psychiatric disorders. However, frame-based systems require that the patient is awake with a stereotactic frame affixed to their head for the duration of the surgical planning and implantation of the DBS electrodes. While frameless systems are increasingly available, a reusable re-attachable frame system provides unique benefits. As such, we created a novel reusable MRI-compatible stereotactic frame system that maintains clinical accuracy through the detachment and reattachment of its stereotactic devices used for MRI-guided neuronavigation. Approach . We designed a reusable arc-centered frame system that includes MRI-compatible anchoring skull screws for detachment and re-attachment of its stereotactic devices. We validated the stability and accuracy of our system through phantom, in vivo mock-human porcine DBS-model and human cadaver testing. Main results . Phantom testing achieved a root mean square error (RMSE) of 0.94 ± 0.23 mm between the ground truth and the frame-targeted coordinates; and achieved an RMSE of 1.11 ± 0.40 mm and 1.33 ± 0.38 mm between the ground truth and the CT- and MRI-targeted coordinates, respectively. In vivo and cadaver testing achieved a combined 3D Euclidean localization error of 1.85 ± 0.36 mm ( p < 0.03) between the pre-operative MRI-guided placement and the post-operative CT-guided confirmation of the DBS electrode. Significance . Our system demonstrated consistent clinical accuracy that is comparable to conventional frame and frameless stereotactic systems. Our frame system is the first to demonstrate accurate relocation of stereotactic frame devices during in vivo MRI-guided DBS surgical procedures. As such, this reusable and re-attachable MRI-compatible system is expected to enable more complex, chronic neuromodulation experiments, and lead to a clinically available re-attachable frame that is expected to decrease patient discomfort and costs of DBS surgery.