Pallante, Graham D.

https://orcid.org/0000-0002-9421-4426

Mayo Clinic

Orthopedic One

Citations 4

Cobalt toxicity from third-body wear following revision of fractured ceramic-on-ceramic hip bearings with a metal articulation
Terhune, E. Bailey , Sutter, E. Grant , Balkissoon, Rishi , Pallante, Graham D. , Specht, Lawrence M. , Leikin, Jerrold B., Kwon, Young‐Min , Lewallen, David G. , Gerlinger, Tad L. , Jacobs, Joshua J.

The Bone & Joint Journal | June 1, 2025 | Volume: 107-B | Issue: 6 Supple B | Pages: 92-100

10.1302/0301-620x.107b6.bjj-2024-1114.r1 Get It

AimsCeramic-on-ceramic (CoC) articulations in total hip arthroplasty (THA) have the advantage of low wear but the unique risk of fracture. After revision for CoC-bearing fracture, third-body ceramic particles can lead to massive wear of cobalt-chrome (CoCr) bearings, causing extremely elevated blood cobalt. We present a multicentre series of five cases where patients sustained fractures of ceramic liners, were revised using a CoCr articulation, and rapidly developed severe cobalt toxicity.MethodsWe identified five cases of cobalt toxicity after fractured CoC THA treated with revision to CoCr on polyethylene bearings. Mean follow-up was three years (5 to 72 months) after re-revision to remove the CoCr bearing.ResultsSymptoms of cobalt toxicity occurred at a mean ten months (6 to 12) after revision for ceramic fracture. All patients developed vision and hearing loss, balance difficulties, and peripheral neuropathy. Several had cardiomyopathy, endocrine abnormalities, and local skin discolouration. Only two reported hip pain. Repeat revision for recognized cobalt toxicity occurred at a mean 22 months after revision for ceramic fracture. Mean serum cobalt level at re-revision was 991 ng/ml (normal value < 1 ng/ml; 734 to 1,302). All CoCr femoral heads exhibited massive wear, and deep tissues showed prominent metal staining. Treatment consisted of debridement and revision to a ceramic femoral head with highly cross-linked polyethylene (HXLPE) liner. Serum cobalt improved to a mean 25 μg/l (1 to 76) at final follow-up. All patients reported partial improvement in vision and hearing, however their peripheral neuropathy and balance difficulties did not recover.ConclusionSystemic cobalt toxicity is a devastating complication of ceramic-bearing fracture in THA treated with CoCr bearings, which may not present with hip symptoms. The diagnosis of this syndrome of systemic cobalt toxicity was significantly delayed following systemic symptoms in this series. Debridement and re-revision to a ceramic-on-HXLPE bearing leads to improvement, but not full resolution, of cobalt toxicity complications.Cite this article: Bone Joint J 2025;107-B(6 Supple B):92–100.
Primary Total Hip Arthroplasty in Patients 20 Years Old and Younger
Pallante, Graham D. , Statz, Joseph M. , Milbrandt, Todd A. , Trousdale, Robert T.

Journal of Bone and Joint Surgery | January 24, 2020 | Volume: 102 | Issue: 6 | Pages: 519-525

10.2106/jbjs.19.00699 Get It

Background: Historically, total hip arthroplasty (THA) performed in patients ≤20 years old has been associated with poor survivorship because of bearing-surface wear with conventional polyethylene, acetabular loosening with cemented sockets, and liner fracture in ceramic-on-ceramic (CoC) THA. For this population, there is a paucity of data regarding outcomes of THAs performed with use of modern implants and bearing surfaces. The purpose of the present study was to examine the mid- to long-term outcomes of modern THA in patients ≤20 years old. Methods: Utilizing a single-institution, prospectively collected total joint registry, we retrospectively identified 91 primary THAs performed in 78 patients ≤20 years old from 1998 to 2016. The average patient age was 17 years (range, 11 to 20 years), and the average body mass index was 26 kg/m 2 (range, 16 to 49 kg/m 2 ). Forty-eight THAs (53%) were performed in male patients, and 47 (52%) were performed on the right hip. Bearing surfaces included CoC (53 THAs, 58%), metal-on-highly cross-linked polyethylene (MoP; 28 THAs, 31%), and ceramic-on-highly cross-linked polyethylene (CoP; 10 THAs, 11%). Outcome measures included reoperations, revisions, complications, clinical outcome scores, and bearing-surface wear. Results: At an average follow-up of 8 years (range, 2 to 18 years), the average modified Harris hip score was 92 (range, 54 to 100), and 95% of patients reported feeling “much better” following the surgical procedure. Survivorship at 2, 5, and 10 years postoperatively was 96.7%, 96.7%, and 95.0% for reoperation; 98.9%, 98.9%, and 97.2% for revision; and 91.2%, 91.2%, and 89.5% for complications, respectively. The most common complications were instability (3 THAs, 3%), aseptic acetabular loosening (2 THAs, 2%), and postoperative foot drop (2 THAs, 2%). Linear articular wear averaged 0.019 mm/yr. There were no correlations between age, sex, body mass index, bearing surface, femoral head size, use of cement, or operative time and survivorship from complications, reoperations, or revisions. There were no differences in linear wear among CoC, CoP, and MoP bearing surfaces. Conclusions: In patients ≤20 years old, THAs performed with use of modern implants exhibit excellent clinical outcome scores and survivorship at mid- to long-term follow-up. CoC, CoP, and MoP bearing surfaces have similar survivorship, clinical outcomes, and bearing-surface wear in this population. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Return of an Intact Hook Test Result: Clinical Assessment of Biceps Tendon Integrity After Surgical Repair
Pallante, Graham D. , O’Driscoll, Shawn W. , Fitzsimmons, James S

Orthopaedic Journal of Sports Medicine | February 25, 2019 | Volume: 7 | Issue: 2 | Pages: No page available

10.1177/2325967119827311 Get It

Background: The hook test is a sensitive and specific tool that has been previously described for diagnosing distal biceps tendon ruptures in an efficient, cost-effective manner. However, its application in postoperative evaluations after surgical repair of distal biceps tendon ruptures is not documented. Hypothesis/Purpose: We hypothesized that the hook test result returns to normal at some point postoperatively after distal biceps repair. This information could be used in decision making during follow-up examinations with both normal and abnormal findings. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: We retrospectively reviewed records of distal biceps repair. Between July 1, 2003, and July 1, 2016, a total of 56 patients underwent distal biceps repair and also had clear documentation of the results of the hook test during the postoperative period. Hook test results consisted of “intact,” “abnormal,” or “absent.” The timing of the return to a normal hook test result was recorded. Results: Overall, 51 of 57 (89%) repairs were documented to have the hook test result return to “intact.” The test result returned to intact by a mean of 10 weeks after surgery (range, 2 weeks to 15 months). The biceps tendon was intact according to the hook test at the 4-month follow-up in 45 of the 51 patients (88%) in whom it ultimately returned. The hook test result was abnormal in 5 repairs in 5 patients with only a short-term follow-up, ranging from 2 to 7 weeks postoperatively. One patient with an abnormal hook test result at 2 weeks postoperatively underwent revision and was confirmed to have a partial tear of the biceps insertion. His hook test result returned to intact 3 months after revision repair. Conclusion: The hook test result returns to normal in patients who undergo distal biceps repair in the primary and revision settings with adequate follow-up. The vast majority of patients have a normal hook test result by 4 months postoperatively. An abnormal hook test result at 4 months postoperatively may indicate a failed repair and should prompt further investigation.
Revision total hip arthroplasty after removal of a fractured well-fixed extensively porous-coated femoral component using a trephine
Amanatullah, Derek F. , Siman, Homayoun , Pallante, Graham D. , Haber, Daniel B., Trousdale, Robert T. , Sierra, Rafael J.

The Bone & Joint Journal | September 1, 2015 | Volume: 97-B | Issue: 9 | Pages: 1192-1196

10.1302/0301-620x.97b9.35037 Get It

When fracture of an extensively porous-coated femoral component occurs, its removal at revision total hip arthroplasty (THA) may require a femoral osteotomy and the use of a trephine. The remaining cortical bone after using the trephine may develop thermally induced necrosis. A retrospective review identified 11 fractured, well-fixed, uncemented, extensively porous-coated femoral components requiring removal using a trephine with a minimum of two years of follow-up.The mean time to failure was 4.6 years (1.7 to 9.1, standard deviation (sd) 2.3). These were revised using a larger extensively porous coated component, fluted tapered modular component, a proximally coated modular component, or a proximal femoral replacement. The mean clinical follow-up after revision THA was 4.9 years (2 to 22, sd 3.1). The mean diameter of the femoral component increased from 12.7 mm (sd 1.9) to 16.2 mm (sd 3.4; p > 0.001). Two revision components had radiographic evidence of subsidence that remained radiographically stable at final follow-up. The most common post-operative complication was instability affecting six patients (54.5%) on at least one occasion.A total of four patients (36.4%) required further revision: three for instability and one for fracture of the revision component. There was no statistically significant difference in the mean Harris hip score before implant fracture (82.4; sd 18.3) and after trephine removal and revision THA (81.2; sd 14.8, p = 0.918).These findings suggest that removal of a fractured, well-fixed, uncemented, extensively porous-coated femoral component using a trephine does not compromise subsequent fixation at revision THA and the patient’s pre-operative level of function can be restored. However, the loss of proximal bone stock before revision may be associated with a high rate of dislocation post-operatively.Cite this article: Bone Joint J 2015;97-B:1192–6.