Back to Authors

Kouzani, Abbas Z.

https://orcid.org/0000-0002-6292-1214

Mayo Clinic

Deakin University

Citations 10

Technological Approaches and Translational Challenges in Bedside External Ventricular Drain Placement: A Systematic Review
Hawkes, Maximiliano A. , Cabrera, Juan M. Rojas , Hong, Lydia, Shin, Hojin, Sung, Jaeyun , Kouzani, Abbas Z., Lee, Kendall, Scheitler, Kristen M. , Hawkes, M A , Sung, Jaeyun , Rojas Cabrera, Juan M , Sharaf, Basel , Kouzani, Abbas Z. , Oh, Yoonbae , Lee, Kendall H.

Operative Neurosurgery | February 4, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1227/ons.0000000000001925 Get It

BACKGROUND AND OBJECTIVES: External ventricular drain (EVD) placement is the most commonly performed bedside emergent neurosurgical procedure. However, catheter misplacement occurs in approximately 25% of cases, potentially resulting in neurological injury or the need for repositioning, highlighting the need for safer and more accurate placement techniques. This review aims to (1) summarize technological innovations developed to enhance the accuracy and safety of bedside EVD placement, (2) evaluate their reported benefits and limitations, and (3) identify key barriers to their clinical implementation in critical care settings. METHODS: We conducted a systematic review of PubMed, Embase, and Scopus combining terms related to EVD placement and assistive technologies. All the studies evaluated EVD placement using simulations, phantoms, cadavers, and patient procedures conducted at the bedside and in the operating room. RESULTS: We identified 3898 records, and 76 studies met the inclusion criteria. Of these, 30 studies compared stereotactic systems, ultrasound guidance, frameless neuronavigation, and augmented or mixed reality technologies to the freehand technique. These studies consistently reported improved accuracy with advanced systems although complication rates and procedural times were variably reported. An additional 35 and 12 studies evaluated nonimmersive and immersive technologies, respectively, in noncomparative settings. Most of these demonstrated high first-pass success and mean tip deviations under 3 mm. Variability in the definitions of accuracy and procedural metrics limited data synthesis, but the overall findings suggest a promising trajectory for technology-assisted EVD placement. CONCLUSION: Assistive technologies for EVD placement show potential to improve accuracy and safety over the freehand technique. These early successes signal potential to improve bedside neurosurgical care. Realizing this promise will require future studies to standardize accuracy metrics, report time, and safety outcomes consistently and validate performance in real-world critical care settings.
Three-dimensional surface scanning for registration in stereotactic neurosurgery: a cadaveric feasibility study
Hussein, S.H., Koller, Adam L., Cabrera, Juan M. Rojas , Shin, Hojin , Elgohary, Mohamed, Sung, Jaeyun , Lee, Kendall H. , Koller, Adam , Scheitler, Kristen M. , Hanson, Christian, El-Gohary, Mohamed M., Sung, Jaeyun , Rojas Cabrera, Juan M , Koller, Adam L , Sharaf, Basel , Hanson, Christian, Morris, Jonathan M. , Oh, Yoonbae , Hawkes, Maximiliano A. , Kouzani, Abbas Z. , Blaha, Charles D.

Journal of Neurosurgery | December 8, 2025 | Volume: 144 | Issue: 2 | Pages: 305-314

10.3171/2025.7.jns25870 Get It

OBJECTIVE Achieving submillimetric accuracy in stereotactic neurosurgery remains critical for safely targeting deep brain structures. Current workflows rely on intraoperative CT to register stereotactic frames to preoperative imaging, but this introduces additional radiation exposure, cost, and workflow complexity. Three-dimensional surface scanning (3DSS) potentially offers a fast radiation-free alternative capable of capturing detailed craniofacial anatomy and frame geometry. Therefore, the aim of this cadaveric study was to evaluate the feasibility, accuracy, and navigational compatibility of integrating 3DSS into stereotactic workflows as a potential replacement for intraoperative CT. METHODS A human cadaveric head was imaged with both thin-slice CT and structured-light 3DSS after mounting stereotactic frame components. CT, 3DSS, and computer-aided design (CAD) models were registered using a multistep point cloud alignment pipeline involving the fast point feature histogram, the random sample consensus method, and the iterative closest point algorithm. Accuracy was assessed using surface deviation error, root mean square error (RMSE), and fiducial registration error within a commercial neuronavigation platform. RESULTS Fusion of the 3D facial scan with CT provided a mean surface deviation error of approximately 0.4 mm. Registration of the 3DSS-derived N-bar localizer to its CAD reference model produced a frame alignment RMSE of 1.3 mm. Within the navigation system, the 3DSS-based workflow achieved a mean fiducial registration error of 0.14 mm (range 0.02–0.20 mm), outperforming the conventional CT-based method (mean error 0.20 mm, range 0.09–0.40 mm). CONCLUSIONS The 3DSS-based method enabled precise submillimetric stereotactic registration without the need for intraoperative CT, reducing radiation exposure and operative complexity. This workflow is fully compatible with existing navigation systems and could serve as a practical radiation-free alternative in stereotactic neurosurgery. Future work will focus on automating frame detection, incorporating artificial intelligence–driven fusion methods, and validating this approach in live surgical settings.
Defining the Spatial Resolution of Analyte Recovery during Microperfusion-Based Sampling of Brain Parenchyma
Stangler, Luke A, Chang, Su-Youne , Kim, Inyong , Bennet, Kevin E. , Howe, Charles L. , Choi, Jonghoon, Howe, Charles L , Choi, Jonghoon , Kouzani, Abbas Z. , Burns, Terry C. , Gompel, Jamie J. Van , Worrell, Gregory A.

ACS Chemical Neuroscience | August 19, 2024 | Volume: 15 | Issue: 17 | Pages: 3220-3227

10.1021/acschemneuro.4c00410 Get It

Anti‐manic effect of deep brain stimulation of the ventral tegmental area in an animal model of mania induced by methamphetamine
Houghton, Tristan, Lee, Kendall H. , Bennet, Kevin E. , Quevedo, João , Valvassori, Samira S. , Quevedo, João , Tye, Susannah J , Varela, Roger B. , Boschen, Suelen L. , Yates, Nathanael J. , Blaha, Charles D. , Kouzani, Abbas Z. , Berk, Michael , Tye, Susannah J.

Bipolar Disorders | April 1, 2024 | Volume: 26 | Issue: 4 | Pages: 376-387

10.1111/bdi.13423 Get It

Abstract Background Treatment of refractory bipolar disorder (BD) is extremely challenging. Deep brain stimulation (DBS) holds promise as an effective treatment intervention. However, we still understand very little about the mechanisms of DBS and its application on BD. Aim The present study aimed to investigate the behavioural and neurochemical effects of ventral tegmental area (VTA) DBS in an animal model of mania induced by methamphetamine (m‐amph). Methods Wistar rats were given 14 days of m‐amph injections, and on the last day, animals were submitted to 20 min of VTA DBS in two different patterns: intermittent low‐frequency stimulation (LFS) or continuous high‐frequency stimulation (HFS). Immediately after DBS, manic‐like behaviour and nucleus accumbens (NAc) phasic dopamine (DA) release were evaluated in different groups of animals through open‐field tests and fast‐scan cyclic voltammetry. Levels of NAc dopaminergic markers were evaluated by immunohistochemistry. Results M‐amph induced hyperlocomotion in the animals and both DBS parameters reversed this alteration. M‐amph increased DA reuptake time post‐sham compared to baseline levels, and both LFS and HFS were able to block this alteration. LFS was also able to reduce phasic DA release when compared to baseline. LFS was able to increase dopamine transporter (DAT) expression in the NAc. Conclusion These results demonstrate that both VTA LFS and HFS DBS exert anti‐manic effects and modulation of DA dynamics in the NAc. More specifically the increase in DA reuptake driven by increased DAT expression may serve as a potential mechanism by which VTA DBS exerts its anti‐manic effects.
Cocaine increases stimulation-evoked serotonin efflux in the nucleus accumbens
Yuen, Jason , Goyal, Abhinav , Rusheen, Aaron E. , Berk, Michael , Kim, Jee Hyun , Bennet, Kevin E. , Lee, Kendall H. , Shin, Hojin , Shin, Hojin , Berk, Michael , Kouzani, Abbas Z. , Tye, Susannah J. , Blaha, Charles D. , Oh, Yoonbae

Journal of Neurophysiology | January 5, 2022 | Volume: 127 | Issue: 3 | Pages: 714-724

10.1152/jn.00420.2021 Get It

Serotonin plays a vital role in drug addiction. Here, using N-shaped fast-scan cyclic voltammetry, we demonstrated the effect of cocaine on the phasic release of serotonin at the nucleus accumbens core. To the best of our knowledge, this has not previously been elucidated. Our results not only reinforce the role of serotonin in the mechanism of action of cocaine but also help to fill a gap in our knowledge and provide a baseline for future studies in cocaine addiction.
An Investigation Into Miniaturised Closed-Loop DBS Devices
Corva, Dean M. , Adams, Scott , Bennet, Kevin E. , Berk, Michael , Kouzani, Abbas Z. , Kouzani, Abbas Z , Berk, Michael , Hashemi, Parastoo

IEEE Transactions on Medical Robotics and Bionics | July 7, 2021 | Volume: 3 | Issue: 3 | Pages: 671-680

10.1109/tmrb.2021.3095361 Get It

Analysis of Carbon-Based Microelectrodes for Neurochemical Sensing
Manciu, Felicia , Barath, Abhijeet S. , Rusheen, Aaron E. , Kouzani, Abbas Z. , Hodges, Deidra , Guerrero, Jose, Tomshine, Jonathan R. , Lee, Kendall H. , Bennet, Kevin E. , Barath, Abhijeet, Rusheen, Aaron E , Kouzani, Abbas Z , Tomshine, Jonathan, Manciu, Felicia S , Oh, Yoonbae

Materials | September 30, 2019 | Volume: 12 | Issue: 19 | Pages: 3186

10.3390/ma12193186 Get It

The comprehensive microscopic, spectroscopic, and in vitro voltammetric analysis presented in this work, which builds on the well-studied properties of carbon-based materials, facilitates potential ways for improvement of carbon fiber microelectrodes (CFMs) for neuroscience applications. Investigations by both, scanning electron microscopy (SEM) and confocal Raman spectroscopy, confirm a higher degree of structural ordering for the fibers exposed to carbonization temperatures. An evident correlation is also identified between the extent of structural defects observed from SEM and Raman results with the CFM electrochemical performance for dopamine detection. To improve CFM physico-chemical surface stability and increase its mechanical resistance to the induced compressive stress during anticipated in vivo tissue penetration, successful coating of the carbon fiber with boron-doped diamond (BDD) is also performed and microspectroscopically analyzed here. The absence of spectral shifts of the diamond Raman vibrational signature verifies that the growth of an unstrained BDD thin film was achieved. Although more work needs to be done to identify optimal parameter values for improved BDD deposition, this study serves as a demonstration of foundational technology for the development of more sensitive electrochemical sensors, that may have been impractical previously for clinical applications, due to limitations in either safety or performance.
A novel re-attachable stereotactic frame for MRI-guided neuronavigation and its validation in a large animal and human cadaver model
Edwards, Christine A. , Rusheen, Aaron E. , Paek, Seungleal, Lee, Kristen H, Dennis, Kendall D. , Bennet, Kevin E. , Kouzani, Abbas Z. , Lee, Kendall H. , Goerss, Stephan J., Paek, Seungleal B, Kouzani, Abbas Z , Oh, Yoonbae , Jacobs, Joshua J.

Journal of Neural Engineering | August 20, 2018 | Volume: 15 | Issue: 6 | Pages: 066003

10.1088/1741-2552/aadb49 Get It

Abstract Objective . Stereotactic frame systems are the gold-standard for stereotactic surgeries, such as implantation of deep brain stimulation (DBS) devices for treatment of medically resistant neurologic and psychiatric disorders. However, frame-based systems require that the patient is awake with a stereotactic frame affixed to their head for the duration of the surgical planning and implantation of the DBS electrodes. While frameless systems are increasingly available, a reusable re-attachable frame system provides unique benefits. As such, we created a novel reusable MRI-compatible stereotactic frame system that maintains clinical accuracy through the detachment and reattachment of its stereotactic devices used for MRI-guided neuronavigation. Approach . We designed a reusable arc-centered frame system that includes MRI-compatible anchoring skull screws for detachment and re-attachment of its stereotactic devices. We validated the stability and accuracy of our system through phantom, in vivo mock-human porcine DBS-model and human cadaver testing. Main results . Phantom testing achieved a root mean square error (RMSE) of 0.94 ± 0.23 mm between the ground truth and the frame-targeted coordinates; and achieved an RMSE of 1.11 ± 0.40 mm and 1.33 ± 0.38 mm between the ground truth and the CT- and MRI-targeted coordinates, respectively. In vivo and cadaver testing achieved a combined 3D Euclidean localization error of 1.85 ± 0.36 mm ( p < 0.03) between the pre-operative MRI-guided placement and the post-operative CT-guided confirmation of the DBS electrode. Significance . Our system demonstrated consistent clinical accuracy that is comparable to conventional frame and frameless stereotactic systems. Our frame system is the first to demonstrate accurate relocation of stereotactic frame devices during in vivo MRI-guided DBS surgical procedures. As such, this reusable and re-attachable MRI-compatible system is expected to enable more complex, chronic neuromodulation experiments, and lead to a clinically available re-attachable frame that is expected to decrease patient discomfort and costs of DBS surgery.
Evolution of optogenetic microdevices
Kale, Rajas P. , Berk, Michael , Tye, Susannah J. , Kouzani, Abbas Z. , Walder, Ken R. , Berk, Michael , Tye, Susannah J

Neurophotonics | June 26, 2015 | Volume: 2 | Issue: 3 | Pages: 031206

10.1117/1.nph.2.3.031206 Get It

Raman Microscopic Analysis of Internal Stress in Boron-Doped Diamond
Bennet, Kevin E. , Lee, Kendall, Tomshine, Jonathan R. , Sundin, Emma , Kruchowski, James, Durrer, William, Manciu, Bianca, Kouzani, Abbas Z. , Manciu, Felicia , Lee, Kendall H. , Kouzani, Abbas Z , Manciu, Felicia S

Materials | May 26, 2015 | Volume: 8 | Issue: 5 | Pages: 2782-2793

10.3390/ma8052782 Get It

Analysis of the induced stress on undoped and boron-doped diamond (BDD) thin films by confocal Raman microscopy is performed in this study to investigate its correlation with sample chemical composition and the substrate used during fabrication. Knowledge of this nature is very important to the issue of long-term stability of BDD coated neurosurgical electrodes that will be used in fast-scan cyclic voltammetry, as potential occurrence of film delaminations and dislocations during their surgical implantation can have unwanted consequences for the reliability of BDD-based biosensing electrodes. To achieve a more uniform deposition of the films on cylindrically-shaped tungsten rods, substrate rotation was employed in a custom-built chemical vapor deposition reactor. In addition to visibly preferential boron incorporation into the diamond lattice and columnar growth, the results also reveal a direct correlation between regions of pure diamond and enhanced stress. Definite stress release throughout entire film thicknesses was found in the current Raman mapping images for higher amounts of boron addition. There is also a possible contribution to the high values of compressive stress from sp2 type carbon impurities, besides that of the expected lattice mismatch between film and substrate.