Back to Authors

Horne, April E.

Mayo Clinic

Mayo Clinic

Citations 4

Development of the Mayo Investigational Neuromodulation Control System: toward a closed-loop electrochemical feedback system for deep brain stimulation
Chang, Su-Youne , Kimble, Christopher J., Kim, Inyong , Paek, Seungleal, Kressin, Kenneth R., Boesche, Joshua B., Whitlock, Sidney V., Eaker, Diane R., Kasasbeh, Aimen, Horne, April E., Blaha, Charles D. , Bennet, Kevin E. , Lee, Kendall H. , Blaha, Charles

Journal of Neurosurgery | October 11, 2013 | Volume: 119 | Issue: 6 | Pages: 1556-1565

10.3171/2013.8.jns122142 Get It

Object Conventional deep brain stimulation (DBS) devices continue to rely on an open-loop system in which stimulation is independent of functional neural feedback. The authors previously proposed that as the foundation of a DBS “smart” device, a closed-loop system based on neurochemical feedback, may have the potential to improve therapeutic outcomes. Alterations in neurochemical release are thought to be linked to the clinical benefit of DBS, and fast-scan cyclic voltammetry (FSCV) has been shown to be effective for recording these evoked neurochemical changes. However, the combination of FSCV with conventional DBS devices interferes with the recording and identification of the evoked analytes. To integrate neurochemical recording with neurostimulation, the authors developed the Mayo Investigational Neuromodulation Control System (MINCS), a novel, wirelessly controlled stimulation device designed to interface with FSCV performed by their previously described Wireless Instantaneous Neurochemical Concentration Sensing System (WINCS). Methods To test the functionality of these integrated devices, various frequencies of electrical stimulation were applied by MINCS to the medial forebrain bundle of the anesthetized rat, and striatal dopamine release was recorded by WINCS. The parameters for FSCV in the present study consisted of a pyramidal voltage waveform applied to the carbon-fiber microelectrode every 100 msec, ramping between −0.4 V and +1.5 V with respect to an Ag/AgCl reference electrode at a scan rate of either 400 V/sec or 1000 V/sec. The carbon-fiber microelectrode was held at the baseline potential of −0.4 V between scans. Results By using MINCS in conjunction with WINCS coordinated through an optic fiber, the authors interleaved intervals of electrical stimulation with FSCV scans and thus obtained artifact-free wireless FSCV recordings. Electrical stimulation of the medial forebrain bundle in the anesthetized rat by MINCS elicited striatal dopamine release that was time-locked to stimulation and increased progressively with stimulation frequency. Conclusions Here, the authors report a series of proof-of-principle tests in the rat brain demonstrating MINCS to be a reliable and flexible stimulation device that, when used in conjunction with WINCS, performs wirelessly controlled stimulation concurrent with artifact-free neurochemical recording. These findings suggest that the integration of neurochemical recording with neurostimulation may be a useful first step toward the development of a closed-loop DBS system for human application.
Development of the Wireless Instantaneous Neurotransmitter Concentration System for intraoperative neurochemical monitoring using fast-scan cyclic voltammetry
Bledsoe, Jonathan M., Kimble, Christopher J., Covey, Daniel P., Blaha, Charles D. , Agnesi, Filippo , Mohseni, Pedram , Whitlock, Sidney V., Johnson, David , Horne, April E., Bennet, Kevin E. , Lee, Kendall H. , Garris, Paul A. , Covey, Dan P. , Blaha, Charles

Journal of Neurosurgery | May 8, 2009 | Volume: 111 | Issue: 4 | Pages: 712-723

10.3171/2009.3.jns081348 Get It

Object Emerging evidence supports the hypothesis that modulation of specific central neuronal systems contributes to the clinical efficacy of deep brain stimulation (DBS) and motor cortex stimulation (MCS). Real-time monitoring of the neurochemical output of targeted regions may therefore advance functional neurosurgery by, among other goals, providing a strategy for investigation of mechanisms, identification of new candidate neurotransmitters, and chemically guided placement of the stimulating electrode. The authors report the development of a device called the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for intraoperative neurochemical monitoring during functional neurosurgery. This device supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially and chemically resolved neurotransmitter measurements in the brain. Methods The FSCV study consisted of a triangle wave scanned between −0.4 and 1 V at a rate of 300 V/second and applied at 10 Hz. All voltages were compared with an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single carbon fiber (r = 2.5 μm) into a glass capillary and pulling the capillary to a microscopic tip by using a pipette puller. The exposed carbon fiber (that is, the sensing region) extended beyond the glass insulation by ~ 100 μm. The neurotransmitter dopamine was selected as the analyte for most trials. Proof-of-principle tests included in vitro flow injection and noise analysis, and in vivo measurements in urethane-anesthetized rats by monitoring dopamine release in the striatum following high-frequency electrical stimulation of the medial forebrain bundle. Direct comparisons were made to a conventional hardwired system. Results The WINCS, designed in compliance with FDA-recognized consensus standards for medical electrical device safety, consisted of 4 modules: 1) front-end analog circuit for FSCV (that is, current-to-voltage transducer); 2) Bluetooth transceiver; 3) microprocessor; and 4) direct-current battery. A Windows-XP laptop computer running custom software and equipped with a Universal Serial Bus–connected Bluetooth transceiver served as the base station. Computer software directed wireless data acquisition at 100 kilosamples/second and remote control of FSCV operation and adjustable waveform parameters. The WINCS provided reliable, high-fidelity measurements of dopamine and other neurochemicals such as serotonin, norepinephrine, and ascorbic acid by using FSCV at CFM and by flow injection analysis. In rats, the WINCS detected subsecond striatal dopamine release at the implanted sensor during high-frequency stimulation of ascending dopaminergic fibers. Overall, in vitro and in vivo testing demonstrated comparable signals to a conventional hardwired electrochemical system for FSCV. Importantly, the WINCS reduced susceptibility to electromagnetic noise typically found in an operating room setting. Conclusions Taken together, these results demonstrate that the WINCS is well suited for intraoperative neurochemical monitoring. It is anticipated that neurotransmitter measurements at an implanted chemical sensor will prove useful for advancing functional neurosurgery.
Innovation in Health Care: A Primer
Varkey, Prathibha, Horne, April E., Bennet, Kevin E.

American Journal of Medical Quality | September 26, 2008 | Volume: 23 | Issue: 5 | Pages: 382-388

10.1177/1062860608317695 Get It

Integrating Physicians, Researchers and Engineers—60Years of Medical Device Innovation at Mayo Clinic
Horne, April E., Bennet, Kevin A., Buntrock, Nathan C., Halovsen, Thomas G., Wehde, Mark

Journal of Medical Devices | July 10, 2008 | Volume: 2 | Issue: 2 | Pages: No page available

10.1115/1.2924269 Get It

Medical innovation is often delayed by the difficulty in developing cooperation among practicing physicians, academics and medical device developers. In Rochester, Minnesota, the Mayo Clinic Division of Engineering has excelled at integrating these specialties, facilitating medical device innovation for the past 60years. In 1948, Mayo Clinic combined an instrument shop with an engineering design services team and created the Division of Engineering. This enabled a unique partnership between physicians, researchers, and product developers. Early innovations from this team include the Mayo heart-lung machine, cardiac monitoring, advances in aero-medicine, surgical stereotaxy, and early transfusion equipment. Today, the Mayo Division of Engineering consists of mechanical, chemical, electrical, biomedical, and software engineers, machinists, and a scientific glass-blower. The division works in close collaboration with project proponents (primarily physicians) within the clinical environment to analyze problems, propose designs, and deliver a clinical solution. From custom 3-D models for support pre-surgical planning to endoscopic heart valve repair devices, the team identifies opportunities and delivers systems that can be quickly translated into medical practice.