Abstract Objective. Modern stereotactic neurosurgery increasingly relies on bilateral and multi-trajectory workflows (e.g. deep brain stimulation (DBS), stereoelectroencephalography (sEEG)), which can exceed the reach and flexibility of conventional frame-based systems. Building on our skull-mounted Navinetics D1 platform, we present a stereotactic frame (Navinetics E1) intended to expand the reachable work envelope, enable independent bilateral targeting, and preserve mechanical accuracy and patient comfort. Approach. We designed the Navinetics E1 stereotactic frame using a center-of-arc architecture with five degrees of freedom per hemisphere ( X, Y, Z , Arc, Collar) and two operating modes: Double Arm (independent left/right arms for simultaneous bilateral targeting) and Single Arm (mechanically coupled arms). The system was designed in CAD and fabricated via carbon fiber-reinforced polylactic acid (PLA-CF) additive manufacturing. Collision-aware MATLAB simulations quantified work volume and admissible approach directions. Mechanical targeting accuracy was evaluated on a ground truth fixture (GTF) platform, with mixed-effects modeling to assess target- and trajectory-dependent effects. Operative feasibility was assessed through an intraoperative entry-point replication test relative to the D1 system. Main results. Compared to the D1, the E1 frame significantly expanded key geometric ranges, including, most notably, 0°–360° Collar rotation and posterior Y -axis reach, thereby increasing the work volume and trajectory range by factors of 3.39 and 8.42, respectively. Mean GTF targeting deviation was 0.78 ± 0.38 mm in Single Arm mode and 1.23 ± 0.36 mm (right) and 1.65 ± 0.47 mm (left) in Double Arm mode. Entry-point replication across 17 clinical cases achieved 76.5% success in overlapping the reference points, providing preliminary evidence of feasibility under real operative conditions. Significance. The E1 frame extends a compact skull-mounted platform to support broader stereotactic reach and trajectory while enabling independent bilateral workflows. These features may reduce intraoperative reconfiguration for complex DBS and sEEG cases. Future work will focus on increasing structural stiffness, improving angular readout/setting, and developing MRI-compatible implementations.
High-Frequency Stimulation of the Ventral Tegmental Area Rescues Respiratory Failure
Abstract Introduction: Opioid use disorder constitutes a significant health crisis in the United States, contributing to high rates of opioid overdose-related deaths. A major driver of these fatalities is fentanyl, a potent synthetic opioid with both sedative and analgesic properties. These properties that make fentanyl clinically effective also increase its addictive potential. Early in opioid addiction, abnormal increases in extracellular dopamine in the nucleus accumbens (NAc) reinforce excessive drug-seeking behaviors which can lead to fatal respiratory depression. Given this mechanism, we investigated whether high frequency stimulation (HFS), mimicking human deep brain stimulation (DBS) of the ventral tegmental area (VTA) could block NAc dopamine increase following an acute lethal dose of fentanyl. We hypothesized that VTA DBS would mitigate these dopaminergic responses and prevent fentanyl-induced respiratory failure. Methods: Multiple cyclic square wave voltammetry (M-CSWV), was applied via a carbon fiber microelectrode in the NAc of urethane-anesthetized male Sprague-Dawley rats. Dopamine levels were recorded at baseline and following acute fentanyl (30 µg/kg, i.v.). HFS (130 Hz frequency, 200 µsec pulse width, and 0.2 mA amplitude) was administered to the VTA before and during fentanyl exposure. Results: Acute fentanyl administration resulted in a 178.2% increase in NAc dopamine levels from baseline, accompanied by a decline in respiratory rates to critically low levels (45 breaths per minute vs. 102 bpm), eventually resulting in 100% mortality. HFS of the VTA did not significantly alter baseline tonic dopamine levels or prevent fentanyl-induced dopamine increase in the NAc but was able to fully rescue fentanyl-induced respiratory failure.
Real-Time Monitoring of Electrode Surface Changes in Fast-Scan Cyclic Voltammetry Using Fourier Transform Electrochemical Impedance Spectroscopy
Feasibility of Applying Fourier Transform Electrochemical Impedance Spectroscopy in Fast Cyclic Square Wave Voltammetry for theIn VivoMeasurement of Neurotransmitters