Back to Authors

Strommen, Jeffrey A.

Mayo Clinic

Mayo Clinic

Citations 6

Potential impact of epidural stimulation on neurogenic bladder function and the value of urodynamic studies throughout usage
Beck, Lisa A., Veith, Daniel D. , Linde, Margaux , Gill, Megan L., Calvert, Jonathan S. , Grahn, Peter J. , Garlanger, Kristin, Husmann, Douglas A. , Lavrov, Igor , Sayenko, Dimitry G. , Strommen, Jeffrey A., Lee, Kendall, Zhao, Kristin D. , Beck, Lisa, Veith, Daniel, Gill, Megan, Calvert, Jonathan, Grahn, Peter, Husmann, Douglas , Strommen, Jeffrey, Zhao, Kristin, Lavrov, Igor , Trentadue, Taylor P , Sayenko, Dimitry G , Lee, Kendall H.

The Journal of Spinal Cord Medicine | July 16, 2021 | Volume: 44 | Issue: 4 | Pages: 515-516

10.1080/10790268.2021.1918979 Get It

Impact of long-term epidural electrical stimulation enabled task-specific training on secondary conditions of chronic paraplegia in two humans
Veith, Daniel D. , Linde, Margaux , Gill, Megan L., Calvert, Jonathan S. , Grahn, Peter J. , Garlanger, Kristin, Husmann, Douglas A. , Lavrov, Igor , Sayenko, Dimitry G. , Strommen, Jeffrey A., Lee, Kendall, Zhao, Kristin D. , Beck, Lisa, Veith, Daniel, Gill, Megan, Calvert, Jonathan, Grahn, Peter, Husmann, Douglas , Strommen, Jeffrey, Zhao, Kristin, Lavrov, Igor , Trentadue, Taylor P , Sayenko, Dimitry G , Beck, Lisa, Lee, Kendall H.

The Journal of Spinal Cord Medicine | March 23, 2020 | Volume: 44 | Issue: 5 | Pages: 800-805

10.1080/10790268.2020.1739894 Get It

Electrophysiological Guidance of Epidural Electrode Array Implantation over the Human Lumbosacral Spinal Cord to Enable Motor Function after Chronic Paralysis
Calvert, Jonathan S. , Grahn, Peter J. , Strommen, Jeffrey A., Lavrov, Igor , Gill, Megan L., Linde, Margaux B. , Straaten, Meegan G. Van , Veith, Daniel D. , Lopez, Cesar , Sayenko, Dimitry G. , Gerasimenko, Yury , Edgerton, V. Reggie , Zhao, Kristin D. , Lee, Kendall H. , Lavrov, Igor A, Brown, Desmond A., Van Straaten, Meegan G, Lavrov, Igor , Trentadue, Taylor P , Beck, Lisa A., Brown, Desmond , Sayenko, Dimitry G

Journal of Neurotrauma | November 15, 2018 | Volume: 36 | Issue: 9 | Pages: 1451-1460

10.1089/neu.2018.5921 Get It

Epidural electrical stimulation (EES) of the spinal cord has been shown to restore function after spinal cord injury (SCI). Characterization of EES-evoked motor responses has provided a basic understanding of spinal sensorimotor network activity related to EES-enabled motor activity of the lower extremities. However, the use of EES-evoked motor responses to guide EES system implantation over the spinal cord and their relation to post-operative EES-enabled function in humans with chronic paralysis attributed to SCI has yet to be described. Herein, we describe the surgical and intraoperative electrophysiological approach used, followed by initial EES-enabled results observed in 2 human subjects with motor complete paralysis who were enrolled in a clinical trial investigating the use of EES to enable motor functions after SCI. The 16-contact electrode array was initially positioned under fluoroscopic guidance. Then, EES-evoked motor responses were recorded from select leg muscles and displayed in real time to determine electrode array proximity to spinal cord regions associated with motor activity of the lower extremities. Acceptable array positioning was determined based on achievement of selective proximal or distal leg muscle activity, as well as bilateral muscle activation. Motor response latencies were not significantly different between intraoperative recordings and post-operative recordings, indicating that array positioning remained stable. Additionally, EES enabled intentional control of step-like activity in both subjects within the first 5 days of testing. These results suggest that the use of EES-evoked motor responses may guide intraoperative positioning of epidural electrodes to target spinal cord circuitry to enable motor functions after SCI.
Sensitivity and specificity of diagnostic ultrasound in the diagnosis of phrenic neuropathy
Boon, Andrea J. , Sekiguchi, Hiroshi , Harper, Caitlin J., Strommen, Jeffrey A., Ghahfarokhi, Leili Shahgholi, Watson, James C. , Sorenson, Eric J. , Ghahfarokhi, Leili S

Neurology | August 28, 2014 | Volume: 83 | Issue: 14 | Pages: 1264-1270

10.1212/wnl.0000000000000841 Get It

Diaphragm depth in normal subjects
Shahgholi, Leili , Baria, Michael R. , Sorenson, Eric J. , Harper, Caitlin J., Watson, James C. , Strommen, Jeffrey A., Boon, Andrea J.

Muscle & Nerve | July 19, 2013 | Volume: 49 | Issue: 5 | Pages: 666-668

10.1002/mus.23953 Get It

ABSTRACTIntroduction: Needle electromyography (EMG) of the diaphragm carries the potential risk of pneumothorax. Knowing the approximate depth of the diaphragm should increase the test's safety and accuracy. Methods: Distances from the skin to the diaphragm and from the outer surface of the rib to the diaphragm were measured using B mode ultrasound in 150 normal subjects. Results: When measured at the lower intercostal spaces, diaphragm depth varied between 0.78 and 4.91 cm beneath the skin surface and between 0.25 and 1.48 cm below the outer surface of the rib. Using linear regression modeling, body mass index (BMI) could be used to predict diaphragm depth from the skin to within an average of 1.15 mm. Conclusions: Diaphragm depth from the skin can vary by more than 4 cm. When image guidance is not available to enhance accuracy and safety of diaphragm EMG, it is possible to reliably predict the depth of the diaphragm based on BMI. Muscle Nerve 49: 666–668, 2014
Two‐dimensional ultrasound imaging of the diaphragm: Quantitative values in normal subjects
Boon, Andrea J. , Harper, Caitlin J., Ghahfarokhi, Leili Shahgholi, Strommen, Jeffrey A., Watson, James C. , Sorenson, Eric J.

Muscle & Nerve | October 16, 2012 | Volume: 47 | Issue: 6 | Pages: 884-889

10.1002/mus.23702 Get It

Introduction : Real time ultrasound imaging of the diaphragm is an under‐used tool in the evaluation of patients with unexplained dyspnea or respiratory failure. Methods : We measured diaphragm thickness and the change in thickness that occurs with maximal inspiration in 150 normal subjects, with results stratified for age, gender, body mass index, and smoking history. Results : The lower limit of normal diaphragm thickness at end expiration or functional residual capacity is 0.15 cm, and an increase of at least 20% in diaphragm thickness from functional residual capacity to total lung capacity is normal. A side to side difference in thickness at end expiration of > 0.33 cm is abnormal. Diaphragm thickness and contractility are minimally affected by age, gender, body habitus, or smoking history. Conclusions : This study confirms previous findings in much smaller groups of normal controls for quantitative ultrasound of the diaphragm and provides data that can be applied widely to the general population. Muscle Nerve 47: 884–889, 2013