Back to Authors

Baria, Michael R.

https://orcid.org/0000-0003-4351-9585

Mayo Clinic

Mayo Clinic

Citations 5

Ultrasound Is a Sensitive Technique to Detect Fasciculations of Cranial Muscles in Amyotrophic Lateral Sclerosis (ALS) (P5.014)
Kassardjian, Charles D. , Baria, Michael R. , Weikamp, Janneke G. , Boon, Andrea J. , O’Gorman, Cullen , Alfen, Nens van

Neurology | December 7, 2023 | Volume: 86 | Issue: 16_supplement | Pages: No page available

10.1212/wnl.86.16_supplement.p5.014 Get It

Complications Following Biologic Therapeutic Injections: A Multicenter Case Series
Eliasberg, Claire D. , Nemirov, Daniel , Mandelbaum, Bert R. , Pearle, Andrew D. , Tokish, John M. , Baria, Michael R. , Millett, Peter J. , Millett, Peter J , Shapiro, Shane A. , Rodeo, Scott A.

Arthroscopy | April 17, 2021 | Volume: 37 | Issue: 8 | Pages: 2600-2605

10.1016/j.arthro.2021.03.065 Get It

Purpose To describe the complications that occur following biologic therapeutic injections. Methods We queried physician members of the Biologic Association, a multidisciplinary organization dedicated to providing a unified voice for all matters related to musculoskeletal biologics and regenerative medicine. Patients included in this study must have (1) received a biologic injection, (2) sustained an adverse reaction, and (3) had a minimum of 1‐year follow‐up after the injection. Patient demographic information, medical comorbidities, diagnoses, and previous treatments were recorded. The type of injection, injection setting, injection manufacturers, and specific details about the complication and outcome were collected. Results In total, 14 patients were identified across 6 institutions in the United States (mean age 63 years, range: 36‐83 years). The most common injections in this series were intra‐articular knee injections (50%), followed intra‐articular shoulder injections (21.4%). The most common underlying diagnosis was osteoarthritis (78.5%). Types of injections included umbilical cord blood, platelet‐rich plasma, bone marrow aspirate concentrate, placental tissue, and unspecified “stem cell” injections. Complications included infection (50%), suspected sterile inflammatory response (42.9%), and a combination of both (7.1%). The most common pathogen identified from infection cases was Escherichia coli (n = 4). All patients who had isolated infections underwent treatment with at least one subsequent surgical intervention (mean: 3.6, range: 1‐12) and intravenous antibiotic therapy. Conclusions This study demonstrates that serious complications can occur following treatment with biologic injections, including infections requiring multiple surgical procedures and inflammatory reactions. Level of Evidence Level IV, case series.
Detecting fasciculations in cranial nerve innervated muscles with ultrasound in amyotrophic lateral sclerosis
O’Gorman, Cullen , Weikamp, Janneke G. , Baria, Michael R. , Engel–Hoek, L. van den , Kassardjian, Charles D. , Boon, Andrea J. , O'gorman, Cullen M , Van Den Engel-Hoek, Lenie , Kassardjian, Charles, Alfen, Nens van

Muscle & Nerve | April 30, 2017 | Volume: 56 | Issue: 6 | Pages: 1072-1076

10.1002/mus.25676 Get It

ABSTRACTIntroductionCranial muscle fasciculations may be difficult to detect in amyotrophic lateral sclerosis (ALS). Ultrasound (US) detection of fasciculations in these muscles may have clinical utility.MethodsPatients with suspected ALS were prospectively enrolled. Nerve conduction studies, needle electromyography (EMG), and US examination of cranial muscles were performed. Controls were examined by US only. Fasciculations were counted and scored for each muscle after 10 or 30 seconds.ResultsThere were 84 patients with ALS. Fasciculations were most frequently found in the genioglossus muscle. Overall, detection rates by US and EMG were similar, but US was more likely to detect frequent fasciculations. Fasciculations were rare in controls, seen in 7 of 1,090 (0.6%) muscles. No control had > 5 fasciculations in any muscle.DiscussionFasciculations were frequently detected in cranial muscles of patients with ALS. US was found to be a sensitive method, and was not impaired by factors such as anxiety and the inability of the patient to relax. Muscle Nerve 56: 1072–1076, 2017
Poster 268 Wrestlers with Limb Deficiencies: A Survey and Participation Considerations
Baria, Michael R. , Driscoll, Sherilyn W. , Terry, Marisa J., Andrews, Karen L., Prideaux, Cara C.

PM&R | September 29, 2014 | Volume: 6 | Issue: 9S | Pages: No page available

10.1016/j.pmrj.2014.08.654 Get It

Diaphragm depth in normal subjects
Shahgholi, Leili , Baria, Michael R. , Sorenson, Eric J. , Harper, Caitlin J., Watson, James C. , Strommen, Jeffrey A., Boon, Andrea J.

Muscle & Nerve | July 19, 2013 | Volume: 49 | Issue: 5 | Pages: 666-668

10.1002/mus.23953 Get It

ABSTRACTIntroduction: Needle electromyography (EMG) of the diaphragm carries the potential risk of pneumothorax. Knowing the approximate depth of the diaphragm should increase the test's safety and accuracy. Methods: Distances from the skin to the diaphragm and from the outer surface of the rib to the diaphragm were measured using B mode ultrasound in 150 normal subjects. Results: When measured at the lower intercostal spaces, diaphragm depth varied between 0.78 and 4.91 cm beneath the skin surface and between 0.25 and 1.48 cm below the outer surface of the rib. Using linear regression modeling, body mass index (BMI) could be used to predict diaphragm depth from the skin to within an average of 1.15 mm. Conclusions: Diaphragm depth from the skin can vary by more than 4 cm. When image guidance is not available to enhance accuracy and safety of diaphragm EMG, it is possible to reliably predict the depth of the diaphragm based on BMI. Muscle Nerve 49: 666–668, 2014