ABSTRACT Background Platelet factor 4‐polyanion enzyme‐linked immunosorbent assays (ELISAs) are considered highly sensitive for diagnosing heparin‐induced thrombocytopenia (HIT), such that current practice guidelines recommend use of ELISA‐negative results to exclude HIT. Once HIT is ruled out, alternative, non‐heparin‐based anticoagulant treatments are ceased, and heparin reintroduction frequently occurs. Methods Antigen‐based and PF4‐dependent functional testing were used to study PF4/polyvinylsulfonate ELISA‐negative platelet‐activating antibodies in HIT‐suspected patients. Results Three patients with clinical presentations consistent with HIT tested negative in an ELISA using PF4‐polyvinylsulfonate (PF4/PVS), an antigenic target very commonly used for HIT antibody screening. All three patients demonstrated PF4‐dependent platelet activation in functional testing that was sensitive to blockade of platelet FcγRIIa receptors and inhibited by high concentrations of heparin, consistent with pathogenic HIT antibodies. Functional testing‐based screening of 500 ELISA‐negative patients identified three additional patients whose sera activated platelets in a PF4‐ and FcγRIIa‐dependent manner and had clinical histories consistent with HIT. Five of the six ELISA‐negative HIT patients were re‐exposed to heparin, which precipitated a decrease in platelet counts in all re‐exposed patients, and one patient developed a new thrombus. Conclusions Recognition of ELISA‐negative HIT is critical to avoid harm due to the cessation of alternative anticoagulation therapy and re‐exposure of these patients to heparin.
Pathogenic PF4/Polyvinylsulfonate ELISA-negative Antibodies in HIT
ABSTRACT BACKGROUND Platelet factor 4-polyanion enzyme-linked immunosorbent assays (ELISAs) are considered highly sensitive for diagnosing heparin-induced thrombocytopenia (HIT), such that current practice guidelines recommend use of ELISA-negative results to exclude HIT. Once HIT is ruled out, alternative, non-heparin-based anticoagulant treatments are ceased, and heparin reintroduction frequently occurs. METHODS Antigen-based and PF4-dependent functional testing were used to study PF4/polyvinyl sulfonate ELISA-negative platelet-activating antibodies in HIT-suspected patients and mice immunized with PF4/heparin. RESULTS Three patients with clinical presentations consistent with HIT tested negative in an ELISA using PF4-polyvinylsulfonate (PF4/PVS), an antigenic target very commonly used for HIT antibody detection. All three patients demonstrated PF4-dependent platelet activation in functional testing that was sensitive to blockade of platelet FcγRIIa receptors and inhibited by high concentrations of heparin, consistent with pathogenic HIT antibodies. Functional testing-based screening of 500 ELISA-negative patients identified three patients whose sera activated platelets in a PF4- and FcγRIIa-dependent manner, and had clinical histories consistent with HIT. Five of the six ELISA-negative HIT patients were re-exposed to heparin, which precipitated a decrease in platelet counts in all re-exposed patients, and one patient developed a new thrombus. To advance the study of ELISA-negative HIT antibodies, mice were immunized with PF4/heparin, and functional and antigenic assays were simultaneously used to successfully identify an ELISA-negative, PF4-dependent platelet-activating murine monoclonal antibody that recapitulated the serological characteristics of ELISA-negative HIT patients. CONCLUSIONS Recognition of ELISA-negative HIT is critical to avoid harm due to the cessation of alternative anticoagulation therapy and re-exposure of these patients to heparin.
Evaluating the potential for iodinated radiocontrast agents to interfere with ADAMTS13 activity testing via fluorescence resonance energy transfer methodology
Abstract Objectives Fluorescence resonance energy transfer (FRET)–based ADAMTS13 activity assays are critical for the diagnosis of thrombotic thrombocytopenic purpura. However, these assays are susceptible to interference. As iodide has been suggested to interfere in laboratory testing via fluorophore quenching or promotion, we aimed to determine whether iodinated contrast (Omnipaque) interferes with the ATS-13 ADAMTS13 Activity Assay 2.0. Methods We evaluated the excitation, emission, and absorbance spectrum of Omnipaque alone and spiked in patient plasma with known ADAMTS13 activity and ADAMTS13 activity on Omnipaque alone, an abnormal control of patient plasma previously observed to display elevated baseline relative fluorescent units, and variable concentrations of patient plasma with known ADAMTS13 activity spiked with Omnipaque. Results No atypical fluorescent peaks were observed on any sample (Omnipaque alone or spiked in plasma) between 250 and 700 nm. There was no difference in the mean ADAMTS13 activity among the various concentrations of plasma spiked with Omnipaque or plasma spiked with saline. Conclusions Iodinated contrast does not appear to interfere—either via spectral overlap of the fluorophore or through physiologic inhibition of the ADAMTS13 enzyme—with ADAMTS13 activity FRET-based assays based on the findings from this in vitro analysis. Delaying sample collection for ADAMTS13 activity testing from suspected patients with thrombotic thrombocytopenic purpura following administration of iodinated radiocontrast agents is not necessary, and recent contrast administration should not yield erroneous ADAMTS13 activity results.
Effect of residual platelets in frozen-thawed plasma on results of dilute Russell’s viper venom time assay for lupus anticoagulant testing
Abstract Objectives To determine the impact of residual platelets on dilute Russell’s viper venom time (DRVVT) assay in frozen-thawed plasma submitted for lupus anticoagulant (LAC) testing. Methods We measured platelet counts in frozen-thawed samples submitted for LAC testing and evaluated the association between platelet count and the DRVVT screening time and ratios. We also spiked platelets into a LAC-positive sample to observe the effect on the DRVVT. Results Progressive increase in platelet count resulted in a statistically significant shortening of the DRVVT assay results on plasma after 1 freeze-thaw cycle. A similar effect was noted on the LAC-positive sample. Conclusions Residual platelets in plasma samples result in shortening of DRVVT assay after 1 freeze-thaw cycle. This may result in a false-negative LAC test result.
“Autoimmune HIT” antibodies in diagnostic samples are a potential artifact and not associated with more severe outcomes
AbstractHeparin-induced thrombocytopenia (HIT) is suspected much more often than it is confirmed. Technically simple platelet factor 4 (PF4)-polyanion enzyme-linked immunosorbent assays (ELISAs) are sensitive but nonspecific. In contrast, accurate functional tests such as the serotonin release assay, heparin-induced platelet activation assay, and PF4-dependent P-selectin expression assay require fresh platelets and have complex assay end points, limiting their availability to specialized reference laboratories. To enable broad deployment of functional testing, we sought to extend platelet viability significantly by optimizing storage conditions and developed a simple functional assay end point by measuring the release of a platelet α-granule protein, thrombospondin-1 (TSP1), in an ELISA format. Platelet cryopreservation conditions were optimized by freezing platelets at controlled cooling rates that preserve activatability. Several-month-old cryopreserved platelets were treated with PF4 or heparin and were evaluated for their ability to be activated by HIT and vaccine-induced immune thrombotic thrombocytopenia (VITT) antibodies in the TSP1 release assay (TRA). HIT and spontaneous HIT patient samples induced significantly higher TSP1 release using both PF4-treated (PF4-TRA) and heparin-treated cryopreserved platelets relative to samples from patients suspected of HIT who lacked platelet-activating antibodies. This latter group included several patients that tested strongly positive in PF4-polyanion ELISA but were not platelet-activating. Four VITT patient samples tested in the TRA activated PF4-treated, but not heparin-treated, cryopreserved platelets, consistent with recent data suggesting the requirement for PF4-treated platelets for VITT antibody detection. These findings have the potential to transform the testing paradigm in HIT and VITT, making decentralized, technically simple functional testing available for rapid and accurate in-hospital diagnosis.
A prospective, blinded study of a PF4-dependent assay for HIT diagnosis
Abstract Heparin-induced thrombocytopenia (HIT) is a life-threatening, prothrombotic, antibody-mediated disorder. To maximize the likelihood of recovery, early and accurate diagnosis is critical. Widely available HIT assays, such as the platelet factor 4 (PF4) heparin enzyme-linked immunosorbent assay (ELISA) lack specificity, and the gold-standard carbon 14–labeled serotonin release assay (SRA) is of limited value for early patient management because it is available only through reference laboratories. Recent studies have demonstrated that pathogenic HIT antibodies selectively activate PF4-treated platelets and that a technically simpler assay, the PF4-dependent P-selectin expression assay (PEA), may provide an option for rapid and conclusive results. Based upon predefined criteria that combined 4Ts scores and HIT ELISA results, 409 consecutive adults suspected of having HIT were classified as disease positive, negative, or indeterminate. Patients deemed HIT indeterminate were considered disease negative in the primary analysis and disease positive in a sensitivity analysis. The ability of PEA and SRA to identify patients judged to have HIT was compared using receiver operating characteristic curve statistics. Using these predefined criteria, the diagnostic accuracy of PEA was high (area under the curve [AUC], 0.94; 95% confidence interval [CI], 0.87-1.0) and similar to that of SRA (AUC, 0.91; 95% CI, 0.82-1.0). In sensitivity analysis, the AUCs of PEA and SRA were also similar at 0.88 (95% CI, 0.78-0.98) and 0.86 (95% CI, 0.77-0.96), respectively. The PEA, a technically simple nonradioactive assay that uses ∼20-fold fewer platelets compared with the SRA, had high accuracy for diagnosing HIT. Widespread use of the PEA may facilitate timely and more effective management of patients with suspected HIT.