Evaluating the potential for iodinated radiocontrast agents to interfere with ADAMTS13 activity testing via fluorescence resonance energy transfer methodology
Abstract Objectives Fluorescence resonance energy transfer (FRET)–based ADAMTS13 activity assays are critical for the diagnosis of thrombotic thrombocytopenic purpura. However, these assays are susceptible to interference. As iodide has been suggested to interfere in laboratory testing via fluorophore quenching or promotion, we aimed to determine whether iodinated contrast (Omnipaque) interferes with the ATS-13 ADAMTS13 Activity Assay 2.0. Methods We evaluated the excitation, emission, and absorbance spectrum of Omnipaque alone and spiked in patient plasma with known ADAMTS13 activity and ADAMTS13 activity on Omnipaque alone, an abnormal control of patient plasma previously observed to display elevated baseline relative fluorescent units, and variable concentrations of patient plasma with known ADAMTS13 activity spiked with Omnipaque. Results No atypical fluorescent peaks were observed on any sample (Omnipaque alone or spiked in plasma) between 250 and 700 nm. There was no difference in the mean ADAMTS13 activity among the various concentrations of plasma spiked with Omnipaque or plasma spiked with saline. Conclusions Iodinated contrast does not appear to interfere—either via spectral overlap of the fluorophore or through physiologic inhibition of the ADAMTS13 enzyme—with ADAMTS13 activity FRET-based assays based on the findings from this in vitro analysis. Delaying sample collection for ADAMTS13 activity testing from suspected patients with thrombotic thrombocytopenic purpura following administration of iodinated radiocontrast agents is not necessary, and recent contrast administration should not yield erroneous ADAMTS13 activity results.
Introduction Establishment of reference intervals (RI) for quantitative assays requires a minimum of 120 qualified normal donor (ND) samples for each partition of an analyte. Based on CLSI EP28 A3C guideline [CLSI. Defining, Establishing, and Verifying Reference Intervals in the Clinical Laboratory; Approved Guideline-Third Edition. CLSI document EP28-A3c. Wayne, PA: Clinical and Laboratory Standards Institute; 2008.], verification of previously established and/or published RI can be performed with a minimum of 20 NDs, especially given complexities of finding qualified NDs. Reagent manufacturers typically provide adult RI, thus facilitating RI verification as a viable option. NDs for the Pediatric (Peds) (<18 years of age) population are difficult to obtain, published RIs are performed with sample cohorts less than the suggested number or only performed with specific instrument/reagent combinations. Herein, we report our experiences with Peds RI. Methods After IRB approval, healthy pediatric outpatients ages 0-18yrs were recruited and consented. Plasma obtained from umbilical cord, finger/heel/ear stick, or venipuncture blood samples (no more than 50 mL or 3 mL per kg) and collected in 3.2% sodium citrate. Assays included Protein (P) C antigen (PCAG) and chromogenic activity (PCFX); P S total (PST), free (PSF) antigen, and functional (SFX); antithrombin antigen (ATAG) and chromogenic activity (ATFX); plasminogen (PLGN) and alpha-2-plasmin inhibitor (A2PI). Assay kits were PCFX - HemosIL® (Werfen, Beford, MA) Protein C, PST - LIATEST® (Diagnostica Stago S.A.S., Asnières sur Seine, France) Protein S, PSF - HemosIL® Free Protein S, SFX - HemosIL® Protein S Activity, ATAG - LIATEST® AT III , ATFX - HemosIL® Liquid Antithrombin, PLGN - HemosIL® Plasminogen, and A2PI - HemosIL® Plasmin Inhibitor performed on the ACL TOP 700 (Werfen) instrument. PCAG - REAADS® Protein C Antigen Test Kit (Corgenix, Inc. Broomfield, CO) was performed on the Janus G3 liquid handler (Revvity, Waltham, MA) and Synergy Neo2 microplate reader (Agilent, Santa Clara, CA). Assay mean and range were calculated. Results Insufficient numbers of patients <1yr were collected. Type of assay, age range in yr and number of samples (n), assay mean in % and range results respectively were as follows: PCAG 1-5 (n=15) 87(46-146); 5-10 (n=82) 81 (45-158); 10-15 (n=169) 84 (44-157); 15-18 (n=107) 91 (57-149). PCFX 1-5 (n=20) 97 (56-140); 5-10 (n=84) 89 (62-135); 10-15 (n=188) 91 (55-140); 15-18 (n=124) 96 (54-138). PST (males): 1-5 (n=10) 120 (96-145); 5-10 (n=46) 108 (75-150); 10-15 (n=91) 111 (80-168); 15-18 (n=63) 113 (72-184). PST (females): 1-5 (n=9) 104 (67-146); 5-10 (n=37) 111 (81-159); Ages 10-15 (n=94) 107 (78-153); 15-18 (n=63) 101 (65-148). PSF (males): 1-5 (n=10) 94 (74-109); 5-10 (n=47) 101 (66-141); 10-15 (n=93) 101 (69-151); 15-18 (n=62) 111 (74-187). PSF (females): 1-5 (n=9) 78 (9-124); 5-10 (n=37) 107 (79-137); 10-15 (n=95) 99 (63-138); 15-18 (n=63) 97 (60-132). SFX (males): 1-5 (n=9) 100 (85-128); 5-10 (n=48) 104 (66-144); 10-15 (n=93) 103 (66-168); 15-18 (n=59) 109 (72-157). SFX (females): 1-5 (n=8) 94 (18-121); 5-10 (n=37) 107 (81-143); 10-15 (n=90) 101 (65-147); 15-18 (n=60) 97 (53-135). ATAG 1-5 (n=19) 104 (80-121); 5-10 (n=83) 104 (78-121); 10-15 (n=188) 104 (66-126); 15-18 (n=126) 101 (67-126). ATFX 1-5 (n=20) 112 (94-135); 5-10 (n=84) 107 (87-123); 10-15 (n=188) 105 (84-138); 15-18 (n=126) 101 (84-129). PLGN 1-5 (n=17) 96 (76-124); 5-10 (n=85) 88 (65-125); 10-15 (n=183) 90 (49-151); 15-18 (n=119) 94 (64-151). A2PI: 1-5 (n=17) 134 (118-151); 5-10 (n=85) 126 (107-139); 10-15 (n=183) 121 (104-140); 15-18 (n=118) 116 (91-143). Conclusions Based on CLSI EP28 A3C criteria for verification, no more than 10% of results should fall outside of established/published RI, for example adult RI. Thus, compared to the SCL adult RI, PLGN assay meets criteria in all age ranges and no additional ND are needed. For the remaining assays, additional ND for ages 1-5 are needed. For ages 5-18 criteria for verification are satisfied for all analytes except PCAG. PCAG has 27, 61, and 19 patients falling below lower RI for ages 5-10, 10-15, and 15-18, respectively.
Conformation-specific RNA aptamers for phenotypic distinction between normal von Willebrand factor and type 2B von Willebrand disease
Abstract The A1 domain in Von Willebrand Factor (VWF) initiates coagulation through binding to platelet glycoprotein GPIbα receptors. Von Willebrand Disease (VWD)-Mutations in A1 that either impair (type 2M) or enhance (type 2B) platelet adhesion to VWF can locally destabilize and even misfold the domain. We leveraged misfolding in the gain-of-function type 2B VWD phenotype as a target, distinct from the normal conformation. Two nuclease-resistant 2′-fluoropyrimidine RNA aptamers were selected to discriminate normal A1 domains from a type 2B V1314D A1 variant in a glycosylated A1A2A3 tri-domain VWF-fragment. Two aptamers, W9 and V1, were isolated that selectively recognize, bind, and inhibit the A1–GPIbα interaction with WT A1A2A3 and V1314D A1A2A3, respectively. These aptamers were tested against their respective recombinant targets, plasma VWF, VWF concentrates, and patient plasma with the heterozygous type 2B VWD R1306W variant using clinical assays, surface plasmon resonance and inhibition assays of platelet adhesion to recombinant A1 and A1A2A3 domains under shear stress. The specificity of W9 and V1 aptamers confirms that pathological conformations of VWD Type 2B proteins are different from normal VWF. The availability of aptamers that distinguish normal plasma-derived VWF from VWD suggests potential applicability in clinical diagnosis of severe gain-of-function phenotypes.
A-144 Liquid chromatography multiple reaction monitoring-based assay for quantitative assessment of fibrinogen levels in clinical samples
Abstract Background Fibrinogen plays a critical role in hemostasis and is essential to clot formation. Changes in the quantity or activity of fibrinogen can lead to disorders affecting coagulation. Thus, it is essential to precisely quantify fibrinogen levels to differentiate between hyperfibrinogenemia in hypercoagulable disorders and dysfibrinogenemia, hypo/afibrinogenemia, and irregular bleeding. Current diagnostic tests that use antibodies to detect fibrinogen or activity-based measures are susceptible to interference from heparin contamination, hemolysis, and hyperbilirubinemia. Here, we evaluated the use of targeted proteomics for developing a quantitative assay for fibrinogen in plasma samples. Methods Four peptides each for alpha and gamma chains of fibrinogen were synthesized using FMOC chemistry on a Liberty Blue (CEM Corp) peptide synthesizer. A targeted multiple reaction monitoring (MRM) assay was developed and optimized using Dionex Ultimate 3000 HPLC connected to a TSQ Altis triple quadrupole mass spectrometer (Thermo Scientific). Evaluations were conducted using a range of standards, such as pure protein, WHO plasma and commercially available plasma with known fibrinogen amounts for the accurate quantitation of fibrinogen. Calibration curves were generated using different dilutions in various matrices. The repeatability and precision of the assay were evaluated across five different days. The plasma samples were processed and digested in a 96-well plate and subjected to C18 clean-up using a Bravo automated liquid handler (Agilent). All samples were spiked-in with corresponding heavy-labeled peptides prior to digestion with trypsin. Multiple reaction monitoring assays were performed on tryptic digests of plasma samples. Results Calibration curves using commercial plasma for all peptides showed linearity from 20 mg/dl to 1,308 mg/dl. This covers the entire clinical range including normal (200-350 mg/dl), deficient states (<100 mg/dl) and excess production (>350 mg/dl) that can be used for evaluation of bleeding disorders including consumption coagulopathy and hyperfibrinogenemia. Based on the overall performance in terms of linearity, limit of detection/quantitation, carryover and coefficient of variation (CV) across five different days, two peptides per chain were finally selected for developing the quantitative assay. The intra-assay variability was <5% and intra-day CV was ∼20%. This assay is currently being tested on a variety of clinical samples representing a range of fibrinogen levels. Conclusions Our study focused on assessing whether multiplexed MRM assay could be implemented to measure fibrinogen levels in plasma. Our data indicate the feasibility of MRM-based assays for determining fibrinogen levels as an alternative to existing non-mass spectrometry-based activity or antigen assays.
Low ADAMTS13 Activity in Patients with Liver Disease- Thrombotic Thrombocytopenic Purpura or Not?
Introduction: Patients with liver injury have hemostatic defects including reduced ADAMTS13 (A disintegrin and metalloproteinase with thrombospondin type 1 motif, member 13). Severe deficiency of ADAMTS13 (ADMS13) activity (< 10%) is pathognomonic for thrombotic thrombocytopenic purpura (TTP), a rare thrombotic microangiopathy (TMA). Differentiating TTP from severe liver injury is complex for multiple reasons including 1) low baseline ADMS13 2) concomitant coagulopathies complicating differentiation from disseminated intravascular coagulation (DIC) 3) ADMS13 activity (ADMS13:AC) assay interference (hyperbilirubinemia (>30mg/dL) can cause artifactual reduction of ADMS13:AC). Here we sought to characterize the clinical presentation, management, and outcomes of patients with liver injury presenting with thrombocytopenia (TCP), microangiopathic hemolytic anemia (MAHA) and low ADMS13:AC at our institution. Methods: In this retrospective study, after IRB approval, electronic medical records (EMR) of institutional patients who had ADMS13:AC and inhibitor profile performed in our special coagulation laboratory between 2018 and July 17, 2023, were reviewed. Eligible patients had ADMS13:AC ≤20% were ≥ 18 years and had evidence of liver injury at time of ADMS13. Liver injury was defined as ALT or AST elevations greater than two times the upper level of normal within one month prior to ADMS13:AC testing, history of end stage liver disease or cirrhosis, or liver transplant with evidence of graft dysfunction. Details regarding clinical presentation, management and outcomes were extracted from the EMR. PLASMIC and ISTH DIC scores were retrospectively calculated. Results: 70 patients had at least one ADMS13:AC < 20% during the study period. 28/70 patients met liver injury inclusion criteria and 20/28 had TCP and MAHA. Of those 20 patients, median age at initial ADMS13:AC was 56.5 years (29-85). Most patients (n=14) had ADMS13:AC of 10-20%. ADMS13:AC was < 5% and 5-10% in 3 patients each. Eleven patients had a positive inhibitor with a median Bethesda titer of 1.85 BU (0.5-3.9). Etiology of liver included: ischemic hepatopathy (n=8), liver graft failure (n=4), liver metastasis (n=3), cirrhosis (n=2), alcoholic hepatitis (n=1), unknown (n=2). Median hemoglobin and platelet (plt) count at time of ADMS13 was 7 g/dL (6.4-13.2) and 30 x10 9/L (3-98), respectively. 7/20 patients had a PLASMIC score of ≥5; PLASMIC score was ≥5, in 2/6 patients with ADMS13:AC <10%. 16/18 patients had an ISTH DIC score ≥5. 18/20 patients had a creatinine > 2 mg/dL or were receiving renal replacement therapy the time of ADMS13: AC. 7/20 patients had total or direct bilirubin of >30mg/dL. Eight/20 patients were treated with plasma exchange (PEX) for a median duration of 7 days (2-13). 66.7% of pts with ADMS13:AC <10% received PEX. Glucocorticoids and Rituximab were used with the intent to treat TTP in 7 and 3 patients, respectively. Caplacizumab was used in 2 patients. 3/8 (37.5%) patients receiving PEX demonstrated normalization of MAHA. One of these patients demonstrated improvement but not normalization of plts (Table 1B, case 5). All patients had recurrence of hematologic abnormalities after PEX was stopped. One patient was treated with plasma infusion with stabilization in plt count. There were 13 and 15 deaths within 1 and 6 months of first ADMTS13:AC, respectively. One death was potentially attributable to management of TTP (Table 1B, case 1). There was no difference in time to death or mortality with the use of PEX. Repeat ADMS13:AC remote from PEX, TCP and MAHA was available for 1/5 surviving patients. This patient (Table1, case 2) had normalization of ADMS:AC after undergoing liver transplant. Conclusion: The differential diagnosis of TCP and MAHA in patients with liver injury includes hepatic dysfunction, DIC and TMA. In the current cohort, 89% of evaluable patients met criteria for overt DIC per ISTH criteria. Due to a low ADMTS13:AC, 40% of patients underwent a trial of PEX with 37.5% demonstrating improvement in MAHA that was not sustained upon discontinuation of PEX due to persistent liver dysfunction. Six-month mortality was 75% and use of PEX did not affect mortality. Given the high mortality, further studies evaluating which patients with TMA and liver injury are more likely to benefit from therapies typically used to treat TTP are necessary.
Effect of residual platelets in frozen-thawed plasma on results of dilute Russell’s viper venom time assay for lupus anticoagulant testing
Abstract Objectives To determine the impact of residual platelets on dilute Russell’s viper venom time (DRVVT) assay in frozen-thawed plasma submitted for lupus anticoagulant (LAC) testing. Methods We measured platelet counts in frozen-thawed samples submitted for LAC testing and evaluated the association between platelet count and the DRVVT screening time and ratios. We also spiked platelets into a LAC-positive sample to observe the effect on the DRVVT. Results Progressive increase in platelet count resulted in a statistically significant shortening of the DRVVT assay results on plasma after 1 freeze-thaw cycle. A similar effect was noted on the LAC-positive sample. Conclusions Residual platelets in plasma samples result in shortening of DRVVT assay after 1 freeze-thaw cycle. This may result in a false-negative LAC test result.
Sialic acid–bearing paraproteins are implicated in heparin-like coagulopathy in patients with myeloma
Abstract Objectives Despite more than 40 years of experience performing the Bethesda assay (BA), poor intra- and interlaboratory precision remains the biggest laboratory challenge to date. Methods The BA procedure was modeled using stochastic simulation techniques to determine the precision of the BA up to dilutions of 1:4,096, to estimate the minimum significant relative change at various inhibitor titers, and to understand the laboratory procedural variables that could significantly affect the performance of the BA at high dilutions. Results Selecting the lowest dilution tube with a residual activity closest to 25% for calculating the reported Bethesda titer (BT), using a factor activity assay with a coefficient of variation less than or equal to 7.5% in the range of 15% to 50% factor activity level, performing the factor activity measurement in replicates, and minimizing pipette volumetric error resulted in the lowest imprecision in the reported BT. The factor neutralization kinetics of the inhibitor appear to have little impact on the precision of the assay if the incubation time is greater than 90 minutes. Conclusions This in silico model will assist future laboratory efforts in standardizing the quantification of specific coagulation factor inhibitors and improving the precision of the reported results.
An Age Distribution of D-Dimer Values in Normal Healthy Donor Population: An Indirect Verification of the Age-Adjusted D-Dimer Cutoffs for VTE Exclusion
Abstract Introduction: The prevalence of venous thrombosis and pulmonary embolism (VTE) increases with age. Definitive VTE diagnosis or exclusion relies on imaging modalities, which are found to be negative in a high proportion of tested patients. Algorithms based on pretest clinical probability (low and intermediate) in conjunction with negative d-dimer test results have reliably excluded VTE sparing the need for additional imaging studies. Currently, the cutoff for a negative d-dimer is based on reference ranges regardless of age of the donor population. Since baseline d-dimer increases with aging, an age-adjusted d-dimer (AADD) cutoff for patients older than 50 years (age*10 ng/mL FEU) has been shown to improve specificity of diagnosis while still maintaining a high sensitivity (>97%) of detecting VTE/PE (Righini, et al. JAMA, 2014). Due to FDA restrictions, clinical laboratories cannot implement and report such AADD cutoffs. Major hurdles include: AADD cutoffs are assay-dependent, and there is a lack of feasible strategy for laboratories to verify the AADD cutoffs. We hypothesize that an adequate study of age-distribution of baseline d-dimer levels of healthy donors can assist the verification of AADD cutoffs and ultimately ensure patient safety in the VTE patient population. Objective: Establish an age dependent reference range for patients 50 years or older with the HemosIL HS 500 D-dimer reagent on the ACL TOP 700 (Instrumentation Laboratory, Bedford MA, USA); and compare this range with the manufacturer provided and literature recommended AADD cutoffs. Methods: D-dimer assay was performed on plasma samples from normal adult donors per the manufacturers' instructions. D-Dimer age, gender distribution and association were analyzed using non-parametric Wilcoxon rank sum, Kolmogorov-Smirnov tests, and quantile regression methods to estimate the 95th percentile to establish a reference range. Results: We studied 241 healthy donors, ranging from 21-91 years of age. Statistically significant differences between males and females (100 [42%] male) were detected (p-value <0.001; p-value =0.0009). Using CLSI guidelines, these statistical differences (median d-dimer for men = 200, while median d-dimer for women = 300) are not considered clinically significant, since only 6% of women would be outside an overall reference range (CLSI guideline states to partition if over 8% for either group would be outside the overall reference range). Using the quantile regression method, a significant association between d-dimer and age was found at the median (P<0.0001). We then established a reference range (95th percentile) for donors younger than age 50 at 635 ng/mL FEU for both men and women and AADD reference range for patients 50 and older (635 + (age - 50)*10 ng/mL) (Figure 1). This reference range was verified with our sample set, with only 6.2% of donors higher than the established reference limit. If we used the non-AADD cutoff provided by the manufacturer for donors younger than 50 (500 ng/mL FEU) and the literature recommended AADD cutoffs for older donors (age*10 ng/mL FEU), 13.3% of our normal donors were above the limits, resulting in not validating this literature reference range per CLSI guidelines in EP28-A3c. These data imply that if both manufacturer and literature recommended AADD cutoffs were adopted, HemosIL HS 500 D-dimer assay should have sufficient sensitivity and negative predictive value, although with slightly lower specificity than those reported by Righini, et al. for detecting VTE/PE. Conclusion: Our study verifies the association between d-dimer level and age and for the first time, to our knowledge, determined AADD normal range for the HemosIL HS 500 D-dimer assay. The manufacturer and literature recommended AADD cutoffs should provide sufficient sensitivity and negative predictive value for VTE/PE exclusion. Figure 1 Age distribution of D-Dimer values (n=241). Figure 1. Age distribution of D-Dimer values (n=241). Disclosures No relevant conflicts of interest to declare.
Heat inactivation of extended half‐life factor VIII concentrates