Back to Authors

Bryant, Sandra C.

0009-0008-3056-9093

Mayo Clinic

Mayo Clinic

Citations 45

The Incidence and Prevalence of Autoimmune Encephalitis and a comparison to Infectious Encephalitis: A Population-Based Study (P5.401)
Kelly, Cecilia R. , López‐Chiriboga, A. Sebastian , Lennon, Vanda A. , Gadoth, Avi , Smith, Carin, Bryant, Sandra C. , Aksamit, Allen J. , Toledano, Michel , Boeve, Bradley, Tillema, Jan Mendelt, Dubey, Divyanshu , Pittock, Sean J. , McKeon, Andrew , Klein, Christopher J. , Flanagan, Eoin P.

Neurology | December 7, 2023 | Volume: 90 | Issue: 15_supplement | Pages: No page available

10.1212/wnl.90.15_supplement.p5.401 Get It

CSF kappa Free Light Chains as a Potential Quantitative Alternative to Oligoclonal Bands in Multiple Sclerosis (S37.001)
Bryant, Sandra C. , Murray, David , Post, Melissa, Frinack, Jody L. , Saadeh, Ruba , Pittock, Sean J. , McKeon, Andrew , Willrich, Maria Alice V.

Neurology | December 7, 2023 | Volume: 92 | Issue: 15_supplement | Pages: No page available

10.1212/wnl.92.15_supplement.s37.001 Get It

Population-Based Epidemiology Study of Paraneoplastic Neurological Syndromes (2892)
Bryant, Sandra C. , Shah, Shailee , Flanagan, Eoin P. , Paul, Pritikanta , Smith, Carin Y. , McKeon, Andrew , Pittock, Sean J. , Dubey, Divyanshu

Neurology | December 7, 2023 | Volume: 96 | Issue: 15_supplement | Pages: No page available

10.1212/wnl.96.15_supplement.2892 Get It

Complement gene variant effect on relapse of complement-mediated thrombotic microangiopathy after eculizumab cessation
Acosta‐Medina, Aldo A. , Moyer, Ann M. , Go, Ronald S. , Willrich, Maria Alice V. , Fervenza, Fernando C. , Leung, Nelson , Bourlon, Christianne , Spears, Grant M. , Bryant, Sandra C. , Winters, Jeffrey L , Sridharan, Meera , Go, Ronald S , Leung, Nelson , Fervenza, Fernando C , Willrich, Maria A , Acosta-Medina, Aldo A , Winters, Jeffrey L. , Sridharan, Meera

Blood Advances | May 9, 2022 | Volume: 7 | Issue: 3 | Pages: 340-350

10.1182/bloodadvances.2021006416 Get It

AbstractEculizumab is effective for complement-mediated thrombotic microangiopathy (CM-TMA), also known as atypical hemolytic uremic syndrome. Although lifelong therapy had been suggested, discontinuation does not universally lead to relapse. Comprehensive data evaluating risk factors for recurrence following discontinuation are limited. Our aim was to systematically review available literature assessing the role of complement genetic variants in this setting. Reports on CM-TMA and eculizumab withdrawal published before 1 January 2021, were included. Key reasons for patient exclusion were no follow-up after drug withdrawal and patients lacking complement genetic testing. Two-hundred eighty patients from 40 publications were included. Median age was 28 years, and 25 patients had a known history of renal transplant. Complement genetic variants were identified in 60%, most commonly in CFH (n = 59) and MCP/CD46 (n = 38). Of patients with a complement gene variant, 51.3% had ≥1 likely pathogenic/pathogenic variant whereas the remaining had variants of uncertain significance (VUS). Overall relapse rate after therapy discontinuation was 29.6%. Relapse rate was highest among patients with CFH variants and MCP/CD46 variants in canonical splice regions. VUS (P < .001) and likely pathogenic/pathogenic variants (P < .001) were associated with increased relapse. Presence of a renal allograft (P = .009); decreasing age (P = .029); and detection of variants in CFH (P < .001), MCP/CD46 (P < .001), or C3 (P < .001) were all independently associated with relapse after eculizumab discontinuation. Eculizumab discontinuation is appropriate in specific patients with CM-TMA. Caution should be exerted when attempting such a strategy in patients with high risk of recurrence, including a subgroup of patients with MCP/CD46 variants.
Cold whole blood transfusion in civilian trauma patients requiring emergent resuscitation: a retrospective cohort study
Fischmann, Marianna Martini , Bryant, Sandra C. , Zielinski, Martin D. , Stubbs, James R.

No container title available | March 30, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-1413454/v1 Get It

Abstract Background: The use of cold whole blood (WB) is rapidly resurging as one of the treatment modalities of choice for the initial resuscitation of civilian trauma patients across the United States. The purpose of our study was to evaluate the effectiveness and safety of cold whole blood (WB) as compared to blood component therapy (BCT) in resuscitation of civilian trauma patients. Methods: This was a retrospective cohort study of trauma patients who received at least one unit of WB transfusion during emergent resuscitation between November 2015 and October 2019 at a level I trauma center. Primary outcome was mortality up to 30 days after trauma. Secondary outcomes included overall blood product utilization and incidence of transfusion reactions. Outcomes were compared between patients who received WB and a cohort receiving BCT who did not receive WB matched for age, sex, mechanism of injury, heart rate, systolic blood pressure, Glasgow Coma Scale, injury severity score, and FAST results. Results: We included 78 patients who received WB transfusion and 78 matched controls. Within 30 days of injury, there were 19 deaths (24.4%) in the WB cohort and 28 (35.9%) deaths in controls (hazard ratio 0.62, 95% CI 0.33 to 1.15, p = 0.086). Patients in the WB cohort received as many units of blood products as controls (median number of units was 10 (IQR 6, 20) vs. 12 (IQR 6, 23), p = 0.43). The incidence of any transfusion reactions was similar between groups (7.7% in WB vs 9.0% in controls, p = 0.78). Life-threatening reactions did not occur in any of the groups. Conclusions: There was no mortality difference between patients receiving cold WB and BCT. Cold WB was safe in this cohort with no life-threatening transfusion reactions.
Comparison of hematopoietic progenitor cell collection using different inlet flow rates with the Fenwal Amicus
Burgstaler, Edwin A. , Bryant, Sandra C. , Winters, Jeffrey L.

Journal of Clinical Apheresis | January 12, 2022 | Volume: 37 | Issue: 3 | Pages: 206-216

10.1002/jca.21959 Get It

AbstractPurposeWe have used a hematopoietic progenitor cell (HPC) algorithm (standard [STD]) that restricted the inlet flow rate to 65 mL/min for peripheral white blood cell count (PWBC) >35 × 109/L (STD). In this study, we evaluated a technique that allows 85 mL/min, regardless of the PWBC count (high). For patients with PWBC >35 × 109/L, a prospective, randomized comparison of the high flow rate vs the STD PWBC‐based flow rate (65 mL/min) was performed, comparing CD34+ and lymphocyte yields, collection efficiencies (CE1), mononuclear cells (MNC), and granulocytes, red blood cell (RBC), and platelet content.MethodsThe Fenwal Amicus version 4.5 with a heparinized ACD‐A anticoagulant (AC) delivered at a 26:1 AC ratio was used. Paired comparisons between high and STD techniques were assessed with Wilcoxon signed rank tests, with P < .05 considered significant. Data are summarized as medians.ResultsForty patient pairs (autologous) were compared. Diagnoses included primarily multiple myeloma (60%) and lymphoma (37.5%). High had significantly higher median average inlet rates (69 vs 55 mL/min), whole blood processed (20 vs 16 L), and cycles (15 vs 14) than STD. There were no significant differences in pre‐procedure counts. Collection contents were (high/STD): 306/328 × 106 CD34+ cells, 48/59% CD34+ CE1 (significant), 0.2/0.2 × 109/kg lymphocytes, 45/57% lymphocyte CE1, 63/59 × 109 WBC, 15/16 × 109 granulocytes, and 1.9/1.7 × 1011 platelets.ConclusionsThe simpler, standardized high flow technique did not significantly increase or decrease CD34+ cells or lymphocyte yields, but did significantly decrease CD34+ CE1. The effects on cross‐cellular content were minimal and not clinically significant.
Population-Based Epidemiology Study of Paraneoplastic Neurologic Syndromes
Shah, Shailee , Paul, Pritikanta , Bryant, Sandra C. , Devine, Michelle F., Lennon, Vanda A. , Pittock, Sean J. , Dubey, Divyanshu , Paul, Pritikanta , Pittock, S J , Dubey, Divyanshu , Shah, Shailee , Flanagan, Eoin P. , Smith, Carin Y. , McKeon, Andrew

Neurology Neuroimmunology & Neuroinflammation | December 22, 2021 | Volume: 9 | Issue: 2 | Pages: No page available

10.1212/nxi.0000000000001124 Get It

Antibody incidence and red blood cell transfusions in patients on daratumumab
Tauscher, Craig D. , Moldenhauer, Sheila K., Bryant, Sandra C. , DiGuardo, Margaret , Jacob, Eapen K., Tauscher, Craig , Moldenhauer, Sheila, Bryant, Sandra

Transfusion | October 9, 2021 | Volume: 61 | Issue: 12 | Pages: 3468-3472

10.1111/trf.16687 Get It

AbstractBackgroundDaratumumab (Dara), an anti‐CD38 monoclonal antibody for hematologic malignancies, interferes with routine blood bank testing, specifically affecting the antibody screen and identification panels. In 2016, the AABB recommended performing a baseline phenotype or genotype before a patient (Pt) begins taking anti‐CD38 to avoid this interference and potential problems with transfusion. The objective of this study was to assess red blood cell (RBC) utilization and subsequent incidence of alloimmunization to the transfused RBCs in patients receiving Dara.Methods and MaterialsWe monitored 244 patients taking Dara to determine their red blood cell transfusions and incidence of clinically significant antibody formation before and following administration of Dara. Poisson generalized estimating equations with log link were used comparing the post‐Dara incidence and prevalence to those prior, with significance defined as p < .05.ResultsFrom September 1, 2015 to December 22, 2018, 244 patients on Dara were identified, of which 145 patients (59.4%) received a red blood cell transfusion. Antibody screens were performed on 97 of the 145 patients at least 2 weeks following RBC transfusion. Four of the total transfused patients (2.8% total, 4.1% patients with follow‐up antibody screen testing) formed new clinically significant alloantibodies, which was not significantly different from Asare's hematologic incidence (p = .98/p = .49).ConclusionsThis study showed our patients on Dara did not form alloantibodies following RBC transfusion at a higher incidence than similar patient populations.
Abstract 11043: Lipoprotein(a) Cholesterol but not Lipoprotein (a) Mass is Significantly Correlated With Angiographic Coronary Artery Disease and Major Adverse Events
Baudhuin, Linnea M. , Bryant, Sandra C. , Spears, Grant M. , Hartman, Stacy, Berger, Peter B. , Jaffe, Allan S. , Somers, Virend K. , McConnell, Joseph, Jaffe, Allan S.

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.11043 Get It

Introduction: Elevated plasma levels of lipoprotein(a) [Lp(a)] are associated with increased risk for coronary artery disease (CAD), but the strength of the association and whether it is independent of other risk factors remains controversial. Differences in prospective studies may be partially explained by variability in methods used to measure Lp(a). Methods: We utilized two different analytical methods (electrophoretic and immunologic) to measure Lp(a) and determine the predictive value of Llp(a) in assessing angiographic coronary artery disease (CAD) and association with major adverse events in 500 patients. Results: In univariate analyses, median Lp(a) cholesterol and Lp(a) mass were significantly associated with angiographic CAD. In a multivariable model, Lp(a) cholesterol remained a significant correlate of CAD (OR 1.61, 95% CI 1.13-2.31, P = 0.009) while Lp(a) mass was not (OR 1.18, 95% CI 0.95-1.47, P = 0.14). Additionally, on multivariable analysis, the presence of a detectable amount of Lp(a) cholesterol (> or =2.5 mg/dL) was more strongly correlated with CAD than HDL cholesterol < 40 mg/dL, and, along withLp(a) cholesterol, was strongly correlated with major adverse events (OR 2.08 95% CI 1.22-3.56, P = 0.007 and OR 1.22, 95% CI 1.05-1.42, P = 0.012, respectively). Conclusions: Lp(a) cholesterol measured electrophoretically is independently correlated with angiographic CAD and presence of major adverse events, and may be used as an alternative or supplement to Lp(a) mass analysis.
Is It Time to Remove Total Calcium from the Basic and Comprehensive Metabolic Panels? Assessing the Effects of American Medical Association–Approved Chemical Test Panels on Laboratory Utilization
Katzman, Brooke M. , Bryant, Sandra C. , Karon, Brad S.

Clinical Chemistry | September 4, 2020 | Volume: 66 | Issue: 11 | Pages: 1444-1449

10.1093/clinchem/hvaa203 Get It

AbstractBackgroundThe necessity of individual tests within the most commonly used disease-oriented test panels has not been well established. We evaluated test-ordering practices for total calcium, both before and after implementation of American Medical Association (AMA)–approved panels (basic metabolic panel [BMP] and comprehensive metabolic panel [CMP]) in our electronic ordering system.MethodsWe performed a retrospective review of all total calcium orders placed during April and June 2018, before and after implementation of the panels. Orders from inpatient, outpatient, and emergency department (ED) care units were totaled, and the percentage of abnormal test results was calculated. We then queried institutional databases to determine the number of unique patients with calcium-related diagnoses and compared the rates from a 5-month period both before and after implementation of the panels.ResultsTotal test volumes and tests per unique patient increased by more than 3-fold after implementation of calcium-containing AMA-approved panels, with the majority of those orders coming from BMPs and CMPs. The rate of low calcium values increased because of the shift toward more inpatient testing; however, the percentage of abnormal results within each patient population (inpatient, outpatient, ED) decreased. The prevalence of hypo- and hypercalcemia-related diagnoses among patients in the 5 months after implementation did not change significantly (1.29% before implementation vs 1.27% after implementation).ConclusionsImplementation of BMPs and CMPs dramatically increased total calcium testing volumes without changing the rate of calcium-related diagnoses. The results suggest that the increase in total calcium orders associated with panel-based testing largely constitutes excess or unnecessary testing.