Back to Authors

Nichols, William L.

Mayo Clinic

Mayo Clinic

Citations 28

Waldenstrom Macroglobulinemia and the Clinical Implications of Acquired Von Willebrand Syndrome
Chohan, Karan , Zanwar, Saurabh , Thompson, Carrie A. , Chanan‐Khan, Asher , Ansell, Stephen M. , Kumar, Shaji , Pruthi, Rajiv K. , Nichols, William L., Kapoor, Prashant , Abeykoon, Jithma P. , Chohan, Karan L , Go, Ronald S. , Paludo, Jonas , Ailawadhi, Sikander , Habermann, Thomas M. , Witzig, Thomas E. , Gertz, Morie A. , Sridharan, Meera

Blood | November 28, 2022 | Volume: 140 | Issue: Supplement 1 | Pages: 9363-9365

10.1182/blood-2022-168232 Get It

Determinants of Plasma Fibrin D-Dimer Sensitivity for Acute Pulmonary Embolism as Defined by Pulmonary Angiography
Heit, John A. , Minor, Thomas A., Andrews, James C., Nichols, William L., Andrews, James C., Larson, Dirk R. , Li, Hongzhe

Archives of Pathology and Laboratory Medicine | January 28, 2021 | Volume: 123 | Issue: 3 | Pages: 235-240

10.5858/1999-123-0235-dopfdd Get It

Abstract Background. —The reported operating characteristics of the plasma fibrin D-dimer level for the diagnosis of acute pulmonary embolism vary widely. Objective. —To determine the sensitivity, specificity, predictive value, and clinical utility of the D-dimer for the diagnosis of pulmonary embolism, and to describe the effect of D-dimer assay method (enzyme-linked immunosorbent assay [ELISA], latex agglutination, membrane ELISA) and discriminate level, patient location at onset, comorbid disease, duration and intensity of concurrent heparin administration, and duration of symptoms on these operating characteristics. Design. —Prospective laboratory investigation. Setting. —Community and tertiary care teaching hospital. Patients. —Consecutive patients with suspected acute pulmonary embolism referred for pulmonary angiography from April 1993 through March 1996. Measurements. —Baseline characteristics, the duration and intensity of heparin anticoagulation, the time interval between symptom onset and plasma D-dimer testing, pulmonary angiography, and the D-dimer level on the day of pulmonary angiography. Results. —Of 105 consenting patients, 33 (31%) had a positive pulmonary angiogram. The D-dimer sensitivity/negative predictive value for the ELISA, latex agglutination (American Bioproducts Co/Diagnostica Stago and Biopool International), and membrane ELISA were 100%/100%, 94%/94%, 100%/100%, and 97%/96%, respectively, at a discriminate level of 250 μg/L or less. The clinical utility, defined as the prevalence of a negative test, ranged from 17% to 33%. D-dimer sensitivity was unaffected by patient location at onset, comorbid disease, or heparin therapy but was inversely related to the duration of symptoms. Conclusions. —The sensitivity of the plasma fibrin D-dimer for the diagnosis of pulmonary embolism depends on the assay method, the assay-specific discriminate level, and the duration of symptoms. At the appropriate discriminate level, the plasma D-dimer is a sensitive but nonspecific test for the diagnosis of pulmonary embolism.
A study of dedicated haemophilia carrier clinics in the United States: Prevalence, services offered and barriers to development
Marshall, Ariela L. , Nichols, William L., Ashrani, Aneel A. , Miles, Moses E. , Pruthi, Rajiv K. , Pruthi, Rajiv K , Marshall, Ariela , Recht, Michael , Sridharan, Meera , Fischer, Karen M. , Riedel, Angela

Haemophilia | June 15, 2020 | Volume: 26 | Issue: 5 | Pages: No page available

10.1111/hae.14071 Get It

An In Silico Exploration of the Factors That Affect the Precision of the Bethesda Assay
Seheult, Jansen N. , Cardel, Laynalee K., Tange, Julie I, Ashrani, Aneel A. , Nichols, William L., Heikal, Nahla, Chen, Dong , Cardel, Laynalee, Ashrani, Aneel, Chen, Dong , Seheult, Jansen N

American Journal of Clinical Pathology | May 15, 2020 | Volume: 154 | Issue: 5 | Pages: 671-682

10.1093/ajcp/aqaa085 Get It

Abstract Objectives Despite more than 40 years of experience performing the Bethesda assay (BA), poor intra- and interlaboratory precision remains the biggest laboratory challenge to date. Methods The BA procedure was modeled using stochastic simulation techniques to determine the precision of the BA up to dilutions of 1:4,096, to estimate the minimum significant relative change at various inhibitor titers, and to understand the laboratory procedural variables that could significantly affect the performance of the BA at high dilutions. Results Selecting the lowest dilution tube with a residual activity closest to 25% for calculating the reported Bethesda titer (BT), using a factor activity assay with a coefficient of variation less than or equal to 7.5% in the range of 15% to 50% factor activity level, performing the factor activity measurement in replicates, and minimizing pipette volumetric error resulted in the lowest imprecision in the reported BT. The factor neutralization kinetics of the inhibitor appear to have little impact on the precision of the assay if the incubation time is greater than 90 minutes. Conclusions This in silico model will assist future laboratory efforts in standardizing the quantification of specific coagulation factor inhibitors and improving the precision of the reported results.
Comparison of Factor XIII Concentration in Cryoprecipitated Plasma Versus Fresh Frozen Plasma.
Caudill, Jonathan S., Nichols, William L., Plumhoff, Elizabeth, Gastineau, D.A., Rodriguez, Vilmarie , Schulte, S. L., Winters, Jeffrey L. , Gastineau, D A

Blood | April 19, 2020 | Volume: 106 | Issue: 11 | Pages: 4169-4169

10.1182/blood.v106.11.4169.4169 Get It

Abstract BACKGROUND: Coagulation factor XIII deficiency, in either its acquired or inherited form, is a rare cause of abnormal bleeding. In patients with Factor XIII (F XIII) deficiency, recommended means of factor replacement include infusion of fresh frozen plasma (FFP), cryoprecipitated plasma (Cryo), or F XIII concentrates1. Comparisons of F XIII concentration in FFP and Cryo are not well defined. To aid management of F XIII deficiency, we measured F XIII activity and antigen in FFP and Cryo. In addition, we determined concentrations of fibrinogen, factor VIII (F VIII) and von Willebrand factor (VWF), including antigen (VWF:Ag), ristocetin cofactor activity (VWF:RCo) and collagen binding activity (VWF:CB). STUDY DESIGNS AND METHODS: 10 bags each of FFP and of Cryo from blood group O donors obtained from the Mayo Clinic Division of Transfusion Medicine blood bank, were analyzed. F XIII activity was assayed by ELISA detecting activated F XIII-mediated amine incorporation into solid phase fibrinogen (Pefakit, Pentapharm). F XIII antigen was measured using radial immunodiffusion (The Binding Site). Fibrinogen was measured by Clauss kinetic clotting assay (Fibriquik, Biomerieux) and also by endpoint delta OD derived from the prothrombin time (ACL, Instrumentation Lab). F VIII was measured by 1-stage APTT-based assay; VWF:Ag by automated LIA (Diagnostica Stago); VWF:RCo by aggregometry of washed platelets; and VWF:CB by ELISA (Corgenix). RESULTS: Mean concentrations of F XIII activity were 60 U/bag (+/−30) in Cryo and 288 U/bag (+/− 77) in FFP. F XIII antigen concentrations paralleled the activity results and are depicted in Table 1, which also includes results for the other analytes. The mean fluid volumes of Cryo and FFP were 21.3 ml/bag (+/− 2.7) and 245 mL/bag (+/− 29), respectively. Table 1. Comparison of Hemostatic Components in Cryoprecipitated Plasma (Cryo) versus Fresh Frozen Plasma (FFP) Cryoprecipitate Fresh Frozen Plasma Component Mean (SD) Mean (SD) Factor XIII activity 60 U/bag (+/− 30) 288 U/bag (+/− 77) Factor XIII antigen 0.65 mg/bag (+/− 0.23) 2.36 mg/bag (+/− 0.76) Factor VIII 133 U/bag (+/− 36.5) 265 U/bag (+/− 83) Fibrinogen Clauss 184 mg/dl (+/− 44) 725 mg/dl (+/− 199) Fibrinogen ACL 319 mg/dl (+/− 76) 864 mg/dl (+/− 327) VWF:Ag 181 U/bag (+/− 53) 218 U/bag (+/− 70) VWF:RCo 168 U/bag (+/− 34) 221 U/bag (+/− 65) VWF:CB 165 U/bag (+/− 40) 208 U/bag (+/− 71) Bag volume 21.3 ml/bag (+/− 2.7) 245 ml/bag (+/− 29) CONCLUSION: In contrast to some of the other cryoprecipitable coagulation proteins, F XIII is only mildly enriched in Cryo when compared with FFP (about 2- to 3-fold). Although both products are practical means of F XIII replacement, and F XIII is somewhat enriched in Cryo, FFP may be a preferred product for F XIII replacement when infusion volume is not a major consideration (eg, in adults versus small children) and risks of exposure to multiple donors are considered. While Cryo is no longer recommended as the product of choice for VWF (or F VIII) replacement, our studies also demonstrate that Cryo is significantly enriched in VWF (which is not routinely assayed as a quality control measure for Cryo, in contrast to requirements for F VIII and fibrinogen content).
Frequency of Heparin-Induced Thrombocytopenia and Heparin-Dependent IgG Antibodies in Hematopoietic Stem Cell Transplant Recipients.
Elliott, Michelle A. , Plumhoff, Elizabeth, Pruthi, Rajiv K. , Nichols, William L., Litzow, Mark R. , Gastineau, Dennis A. , Heit, John A. , Schulte, Sandra

Blood | April 19, 2020 | Volume: 108 | Issue: 11 | Pages: 4059-4059

10.1182/blood.v108.11.4059.4059 Get It

Abstract Background Heparin-induced thrombocytopenia (HIT) is an immune-mediated drug reaction in which heparin-dependant IgG antibodies (HIT-IgG) to heparin-platelet factor 4 complexes form with the potential for platelet activation with resultant thrombocytopenia (HIT) and thrombosis (HITT). The frequency of HIT-IgG formation and clinically apparent HIT or HITT varies considerably, according to the patient population (surgical versus medical) and type of heparin (unfractionated [UFH] vs low molecular weight [LMWH]). One large prospective study showed a frequency of HIT-IgG formation of 7.5% with clinical HITT in 34.5% of these orthopedic patients receiving prophylactic LMWH and corresponding figures in cardiac surgery patients receiving UFH were 50% and 2%, respectively [Warkentin et al. Blood2000;96: 1703]. Due to daily exposure to heparin flushes (UFH) and prophylactic LMWH (to prevent venoocclusive disease) hematopoietic stem cell transplant (HSCT) recipients may be at risk for HIT/HITT. However, due to anticipated post-transplant thrombocytopenia, clinical cases of HIT/HITT may be overlooked. We retrospectively determined the incidence of HIT-IgG formation and its clinical significance in this population. Methods: HIT-IgG was measured retrospectively using a commercially available ELISA kit in samples collected from patients prior to conditioning therapy and on day 14 post-HSCT. Medical records were reviewed to in order to determine the clinical significance (development of clinical HIT/HITT) in those with detectable HIT-IgG. Patients Samples from a total of 103 HSCT recipients with hematologic malignancy (including 25 myeloma, 17 lymphoma, 16 AML, 14 amyloid, 10 MDS, 10 ALL, 8 CML and 3 CLL) were tested, of which 52 and 49 underwent allogeneic and autologous HSCT, respectively. All patients were exposed to UFH flushes during line care. In addition, all allogeneic recipients received prophylactic subcutaneous dalteparin 5000U daily beginning with conditioning until engraftment. Conditioning regimens included high dose melphalan (n=34), cyclophosphamide/TBI (n=30), carmustine, etoposide, cytarabine, melphalan (n=15), busulfan/cyclophosphamide (n=9), fludarabine/melphalan (n=10) and fludarabine/TBI (n=4). The median age was 51.5 years (20–72) and 68 were male. Results: The median platelet count prior to initiation of conditioning therapy and at day 14 was 157 × 109/L (range: 10–672) and 40 × 109/L (range: 9–289), respectively. Prior to conditioning, two of 103 (1.9%) patients had a positive HIT-IgG assay, that became negative in one and equivocal in the other by day 14 post-HSCT, and one patient had an equivocal HIT assay that became negative by day 14. All 3 were autologous recipients. None of the previously negative patients had a positive HIT-IgG assay at day 14, although 3 patients (2 autologous and one allogeneic) had an equivocal result of uncertain significance. No patients developed clinical or symptomatic thrombosis (HITT). Conclusion: In spite of frequent exposure to heparin, the frequency of seroconversion is low, and in those patients with preexisting HIT-IgG, no patient developed symptomatic thrombosis, including the 2 patients with positive HIT IgG assays prior to conditioning. The low frequency of HIT-IgG formation may reflect the profound immunosuppression of the conditioning regimens employed. Nevertheless, in this population, a high index of clinical suspicion must be maintained.
Platelet Pathology in GATA-1 Dyserythropoietic Macrothrombocytopenia.
White, James G. , Nichols, William L., Steensma, David P.

Blood | April 19, 2020 | Volume: 108 | Issue: 11 | Pages: 1102-1102

10.1182/blood.v108.11.1102.1102 Get It

Abstract Germline mutations in the X-linked hematopoietic transcription factor, GATA-1, have been associated with dyserythropoietic anemia (DEA), macrothrombocytopenia (MTP), and congenital erythropoietic porphyria. Recently, morphological features suggestive of the Gray Platelet Syndrome (GPS) were described in a pedigree with a germline R216Q GATA-1 mutation (Blood106:6a, 2005). The present study has evaluated platelets (Pl) in the electron microscope from members of a previously described pedigree (Blood98:2681–2688, 2001) with GATA-1 G208S, MTP, and dyserythropoiesis without anemia, for whom detailed platelet morphology studies have not been reported. The presence of a hemizygous GATA-1 mutation was confirmed by conventional fluorescent dye chemistry sequencing of DNA from patient peripheral blood mononuclear cells. Their Pl revealed wide variations in size, shape, internal and external structure. Some normal sized and giant Pl contained usual numbers of alpha granules and dense bodies, while most of the large cells were hypogranular. Some contained no membrane systems or organelles. Others were filled with masses of dense tubular system (DTS) channels, and others contained the tubular inclusions found in the Medich Giant Platelets Disorder (Platelets15:345–353, 2004). Many of the hypogranular cells contained small vacuoles that may have been enclosing membranes of alpha granules. Except for the tubular inclusions, all of these structural variations are observed in GPS Pl (Am. J. Pathol.95:445–462, 1979). However, additional striking abnormalities were seen in GATA-1 Pl that are not characteristic of GPS Pl. Many GATA-1 Pl contained unusual, closely associated dense double membranes differing from normal elements of rough endoplasmic reticulum, smooth endoplasmic reticulum, DTS or surface connected open canalicular system (OCS), but resembling channels of the OCS after exposure to EDTA. They were observed previously only in megakaryocytes (Mk) from one family with GATA-1 DEA-MTP (Nat. Genet, 24:266–270, 2000). The dense double membranes were often found in parallel association and, in some examples, isolating areas of cytoplasm. However, the isolated areas were not undergoing autophagic degradation as such areas enclosed by elements of the DTS do in White Platelet Syndrome Pl (Platelets 15:173,2004). Instead, they proved to be another unique feature of GATA-1 platelets, the presence of Pl within Pl. The sequestered cells were usually mature in appearance and often discoid in form with circumferential coils of microtubules. In some GATA-1 Pl there were two Pl within the same cell, and on rare occasions, a Pl within a Pl within a Pl. Pl within Pl have never been observed previously in any human platelet disorder. Another unique feature, related to Pl within Pl, was the frequent Pl to Pl surface attachment of non-activated cells forming large macrothrombocytes with no similarity to aggregates of stimulated normal platelets. Conclusion: The substructural abnormalities of Pl from patients with germline GATA-1 mutations share some overlap with those seen in GPS Pl, but are distinct and unique. The MTP, Pl within Pl and surface Pl to Pl attachments suggest a major defect in the formation and separation of GATA-1 Pl from pro-Pl of the parent Mk, resulting in the MTP characteristic of the disorder.
Novel Mutations in Types 2 & 3 von Willebrand Disease and Correlation with von Willebrand Factor Multimer Patterns.
Titapiwatanakun, Ruetima, Guenther, Jennifer, Asmann, Yan W. , Daniels, Todd M., Heit, John A. , Nichols, William L., Pruthi, Rajiv K.

Blood | April 18, 2020 | Volume: 110 | Issue: 11 | Pages: 2136-2136

10.1182/blood.v110.11.2136.2136 Get It

Abstract Background & Objectives: Diagnosis and classification of VWD are currently based on integration of personal and family bleeding histories and results of protein-based diagnostic tests (VWF:Ag, VWF:RCo, FVIII:C, VWF:CB and VWF multimers) which have performance limitations. Genetic testing is emerging as a complementary diagnostic tool. We have identified mutations and correlated VWF multimer patterns in our patients (pt) with types 2 & 3 VWD, and report novel candidate mutations. Patients & Methods: Unrelated pt with type 3 (n=6) and subtypes 2 (n=22) VWD, from Mayo Comprehensive Hemophilia Center, consented to this IRB approved study. PCR amplification, from genomic DNA, of VWF gene (splice junctions, coding and promoter regions), avoiding pseudogene amplification, followed by ABI® sequencing and analysis (Mutation Surveyor: SoftGenetic®) were performed. Mutations were compared to VWD (ISTH), NCBI NR nucleotide and DV SNP databases. Comparison with available VWF sequences from other vertebrate species was performed. Selected regions not known to contain mutations remain to be sequenced. VWF multimer analysis was performed using a novel in-gel immunostaining and infrared imaging system. Results: Type 2A VWD (n=10), a novel mutation in exon 28 (E28) (V1524G: 2 pt) with characteristic VWF multimer abnormalities (decreased HMWM, increased satellite banding, suggesting enhanced VWF proteolysis). Type 2B VWD (n=6), 2 pt were compound heterozygous for 2 previously reported mutations, the first in E28 (R1306W)/E48 (T2647M) and the second in E28 (V1316M)/E20 (R854Q). Type 2M VWD (n=4): an 84 yr female with personal (spontaneous and post-surgical) and family bleeding histories, VWF:RCo 72%, VWF:Ag 118% (RCo:Ag ratio 0.61), normal FVIII and platelets, and aberrant VWF multimer banding pattern without substantive reduction of HMWM, had a novel mutation in E52 (S2775C; conserved in mouse, rat, chicken and dog); a 14 yr female with a history of bleeding, VWF:RCo 34%, VWF:Ag 68% (RCo:Ag ratio 0.5) and normal FVIII and platelets, was compound heterozygous for a known mutation (R1399C subtype not classified in VWD database) and two novel mutations: E30 (P1725S) (conserved in mouse, rat, dog, cow and chimp) & E49 (T2666M) (conserved in mouse, dog, rat not in chicken). VWF multimers demonstrated abnormal banding pattern without substantive reduction of HMWM; 2 unrelated pt and families with ultra-large and smeary multimers, previously classified as Vicenza variant, had R1374C mutations and were reclassified as Type 2M VWD. Type 2N VWD (n=1) previously reported mutation E20 (R854Q) was confirmed. Type 3 VWD, 2 pt had novel mutations, the first in E22 (E950X) and the second was a compound heterozygote for E43 (R2478Q)/E40 (E2322V) mutations. In general, patients with similar mutations had similar multimer patterns. Conclusions: We report novel candidate mutations in types 2 & 3 VWD and demonstrate novel VWF multimer patterns with our in-gel staining system. Multimer patterns correlated well with the underlying genotype. The novel mutations are likely causative, given their occurrence at highly conserved residues, but this needs to be confirmed with expression studies. Integration of genetic testing into the diagnostic workup of VWD will potentially lead to more accurate diagnosis and subtyping of VWD, and may further refine protein based testing and provide additional biological insight into VWD.
A New Plate Based Plasma von Willebrand Factor (VWF): Ristocetin Cofactor Activity Assay.
Pruthi, Rijiv K., Nichols, William L., Heit, John A. , Owen, Whyte G., Chen, Dong

Blood | April 18, 2020 | Volume: 110 | Issue: 11 | Pages: 2143-2143

10.1182/blood.v110.11.2143.2143 Get It

Abstract Introduction: Assays of plasma von Willebrand factor (VWF) ristocetin cofactor activity (VWF:RCo) are essential for the laboratory diagnosis of von Willebrand disease (VWD). However, the current manual platelet aggregation/aggregometry method has relatively poor operating characteristics. Our goal was to develop a simple, accurate and sensitive platelet based assay. Methods: VWF protein from normal or patient plasma was first captured on the polyclonal anti-VWF antibody coated plastic plate surface. VWF:RCo activity was assayed by the binding of mitotracker (a red fluorochrome)-labeled, formalin-fixed normal platelets in the presence of ristocetin (1mg/ml) and under agitation (200 rpm by vortex). The fluorescence from the bound platelets, measured by a fluorescence microtiter plate reader (Fluor4000, BioRad), was related to the calibrator plasma signal (6∼150% or IU/dL), and reported as % or IU/dL. We tested plasma samples from normal donors (n=16) and known VWD patients (type 1, n=6; type 2, n=9) based on clinical history and levels of plasma VWF antigen (VWF:Ag), VWF:RCo activity (manual platelet aggregation/aggregometry method), factor VIII activity and VWF multimer analysis. Results: For both normal donors and VWD patients, VWF:RCo activities by the plate assay vs. manual platelet aggregation/aggregometry method correlated closely (R2=0.84), and VWF:RCo/VWF:Ag ratios did not differ significantly. Platelet binding to VWF-coated plastic wells is both VWF specific and ristocetin dependent. Conclusions: Although this new platelet based VWF:RCo plate assay is still being optimized and validated, the preliminary data suggest that it is simple, accurate and sensitive.
Hemostatic prophylaxis and colonoscopy outcomes for patients with bleeding disorders: A retrospective cohort study and review of the literature
Azer, Sarah , Eckerman, Amy, Rodriguez, Vilmarie , Nichols, William L., Ashrani, Aneel A. , Hook, C. Christopher , Marshall, Ariela L. , Pruthi, Rajiv K. , Azer, Sarah M, Eckerman, Amy L, Marshall, Ariela

Haemophilia | March 6, 2020 | Volume: 26 | Issue: 2 | Pages: 257-268

10.1111/hae.13954 Get It

AbstractIntroductionHemostatic prophylaxis (HP) is recommended for patients with bleeding disorders (PWBD) before invasive procedures. However, evidence‐based guidelines are needed to determine optimal HP strategies.AimTo determine outcomes of HP for PWBD undergoing colonoscopy.MethodsWe undertook a retrospective cohort study of HP and outcomes of colonoscopy procedures performed between 9 November 1993 and 13 February 2018 for PWBD who received care in the Mayo Clinic Comprehensive Hemophilia Treatment Center.ResultsDuring the study period, 73 PWBD (58 with milder phenotypes: haemophilia, von Willebrand disease [subtypes 1 and 2; II, VII and XI deficiency]) underwent 141 procedures. Preprocedural HP was given to 61%, and interventions were performed in 47%. Of the 39% without preprocedural HP, postprocedural HP was given for 11%. One major (0.7%; 6 days postprocedure despite HP) and 10 minor (7%) bleeding complications occurred, which tended to be in patients with severe disease and/or after excision of larger polyps. There was no significant difference in the rate of bleeding complications with or without preprocedural HP (8.1% vs 5.5%, respectively; P = .74, Fisher's exact test).ConclusionThe low bleeding rates in our cohort suggest that preprocedure HP may be withheld for patients with mild bleeding disorders who undergo colonoscopy with a low likelihood of requiring an intervention or who require only low‐risk intervention. This strategy may be best used in experienced centres, provided optimal local hemostasis measures are undertaken and postprocedural HP is rapidly available if high‐risk intervention is required. Further studies are needed to determine optimal evidence‐based HP strategies for PWBD undergoing colonoscopy.