Back to Authors

Gil, Morayma Reyes

https://orcid.org/0000-0002-8011-4707

Mayo Clinic

Cleveland Clinic

Citations 4

Pathogenic PF4 /Polyanion ELISA ‐Negative Antibodies in HIT
Kanack, Adam J. , Splinter, Noah P., Mauch, Emily, Gil, Morayma Reyes, Jasra, Sakshi , Goodwin, Andrew, Smock, Kristi J. , Ahmad, Hadiyah, Ashrani, Aneel A. , Robinson, Nathaniel L. , Jones, Curtis G., Pechauer, Shannon M., yttre, erin , Aster, Richard H. , Kohlhagen, Mindy , Leger, Rachel, Johns, Gretchen, Murray, David , Zhou, Lu, Wang, Demin, Wen, Renren , Chen, Dong, Pruthi, Rajiv K. , Padmanabhan, Anand , Wang, Demin , Zhou, Lu , Mauch, Emily E, Smock, Kristi J , Kohlhagen, Mindy C, Leger, Rachel R, Chen, Dong , Padmanabhan, Anand , Wang, Demin , Tefera, Leben T. , Gil, Morayma Reyes , Casanegra, Ana I. , Johns, Gretchen S.

American Journal of Hematology | May 2, 2026 | Volume: 101 | Issue: 8 | Pages: 1790-1798

10.1002/ajh.70333 Get It

ABSTRACT Background Platelet factor 4‐polyanion enzyme‐linked immunosorbent assays (ELISAs) are considered highly sensitive for diagnosing heparin‐induced thrombocytopenia (HIT), such that current practice guidelines recommend use of ELISA‐negative results to exclude HIT. Once HIT is ruled out, alternative, non‐heparin‐based anticoagulant treatments are ceased, and heparin reintroduction frequently occurs. Methods Antigen‐based and PF4‐dependent functional testing were used to study PF4/polyvinylsulfonate ELISA‐negative platelet‐activating antibodies in HIT‐suspected patients. Results Three patients with clinical presentations consistent with HIT tested negative in an ELISA using PF4‐polyvinylsulfonate (PF4/PVS), an antigenic target very commonly used for HIT antibody screening. All three patients demonstrated PF4‐dependent platelet activation in functional testing that was sensitive to blockade of platelet FcγRIIa receptors and inhibited by high concentrations of heparin, consistent with pathogenic HIT antibodies. Functional testing‐based screening of 500 ELISA‐negative patients identified three additional patients whose sera activated platelets in a PF4‐ and FcγRIIa‐dependent manner and had clinical histories consistent with HIT. Five of the six ELISA‐negative HIT patients were re‐exposed to heparin, which precipitated a decrease in platelet counts in all re‐exposed patients, and one patient developed a new thrombus. Conclusions Recognition of ELISA‐negative HIT is critical to avoid harm due to the cessation of alternative anticoagulation therapy and re‐exposure of these patients to heparin.
D-Dimer Reporting and Harmonization: Analysis of College of American Pathologists D-Dimer Proficiency Testing Program
Salazar, Eric, Smock, Kristi J. , Cazzolli, Taryn E, Dlott, Jeffrey S., Lickteig, Nathan, Long, Thomas A., Mulvey, J. Justin , Gil, Morayma Reyes, Rollins-Raval, Marian, Walker, Chance Avery, Zantek, Nicole D. , Goodwin, AJ, Zantek, Nicole D , Gil, Morayma Reyes , Rollins‐Raval, Marian A. , Teruya, Jun , Volod, Oksana , Walker, Chance, Wool, Geoffrey D.

Seminars in Thrombosis and Hemostasis | February 6, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/a-2803-3165 Get It

Abstract Measurement of D-dimer, a fibrin degradation product, is crucial for diagnosing thrombotic and fibrinolytic conditions. Despite its expanding utility, D-dimer testing faces challenges due to varying assay methodologies and nonstandardized reporting. To understand D-dimer reporting practices, the College of American Pathologists Hemostasis and Thrombosis Committee analyzed proficiency testing data from D-dimer surveys conducted between 2020 and 2023 across multiple laboratories. The data demonstrate that laboratories commonly report units that differ from the assay package insert when reporting their proficiency testing results. We sought to assess variability in reporting practices and opportunities for improvement in D-dimer reporting amongst participants. To accomplish this, we harmonized all D-dimer results to ng/mL fibrinogen equivalent units from one distributed sample and assessed distinct populations of entries per instrument/reagent combination. Notable trends emerged from this analysis. Data from laboratories using the same instrument/reagent combinations clustered around different means, suggesting issues with unit reporting and/or conversion. Entries reported in mg/L or ug/mL D-dimer units commonly exhibited significant deviations from the dominant population. For one instrument/reagent combination, most reported values differed by approximately twice the certificate of analysis value. This analysis highlights potential issues with D-dimer reporting in proficiency testing. Whether these issues translate into issues with clinical D-dimer reporting requires further study.
Pathogenic PF4/Polyvinylsulfonate ELISA-negative Antibodies in HIT
Kanack, Adam J. , Splinter, Noah P., Mauch, Emily, Gil, Morayma Reyes , Jasra, Sakshi , Goodwin, Andrew , Smock, Kristi J. , Ahmad, Hadiyah, Ashrani, Aneel A. , Robinson, Nathaniel L. , Jones, Curtis G., Pechauer, Shannon M., yttre, erin , Aster, Richard H. , Kohlhagen, Mindy , Leger, Rachel, Murray, David, Zhou, Lu , Wang, Demin , Wen, Renren , Pruthi, Rajiv K. , Padmanabhan, Anand , Mauch, Emily E, Tefera, Leben, Kohlhagen, Mindy C, Leger, Rachel R, Wang, Demin , Tefera, Leben T. , Ahmad, Hadiyah, Casanegra, Ana I. , Jones, Curtis G., Chen, Dong

No container title available | November 6, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1101/2025.10.29.25338884 Get It

ABSTRACT BACKGROUND Platelet factor 4-polyanion enzyme-linked immunosorbent assays (ELISAs) are considered highly sensitive for diagnosing heparin-induced thrombocytopenia (HIT), such that current practice guidelines recommend use of ELISA-negative results to exclude HIT. Once HIT is ruled out, alternative, non-heparin-based anticoagulant treatments are ceased, and heparin reintroduction frequently occurs. METHODS Antigen-based and PF4-dependent functional testing were used to study PF4/polyvinyl sulfonate ELISA-negative platelet-activating antibodies in HIT-suspected patients and mice immunized with PF4/heparin. RESULTS Three patients with clinical presentations consistent with HIT tested negative in an ELISA using PF4-polyvinylsulfonate (PF4/PVS), an antigenic target very commonly used for HIT antibody detection. All three patients demonstrated PF4-dependent platelet activation in functional testing that was sensitive to blockade of platelet FcγRIIa receptors and inhibited by high concentrations of heparin, consistent with pathogenic HIT antibodies. Functional testing-based screening of 500 ELISA-negative patients identified three patients whose sera activated platelets in a PF4- and FcγRIIa-dependent manner, and had clinical histories consistent with HIT. Five of the six ELISA-negative HIT patients were re-exposed to heparin, which precipitated a decrease in platelet counts in all re-exposed patients, and one patient developed a new thrombus. To advance the study of ELISA-negative HIT antibodies, mice were immunized with PF4/heparin, and functional and antigenic assays were simultaneously used to successfully identify an ELISA-negative, PF4-dependent platelet-activating murine monoclonal antibody that recapitulated the serological characteristics of ELISA-negative HIT patients. CONCLUSIONS Recognition of ELISA-negative HIT is critical to avoid harm due to the cessation of alternative anticoagulation therapy and re-exposure of these patients to heparin.
ELISA-Negative Platelet-Activating Anti-PF4 Antibodies Can Cause HIT and Monoclonal Gammopathy of Thrombotic Significance (MGTS)
Kanack, Adam J. , Splinter, Noah P., Mauch, Emily, Gil, Morayma Reyes , Jasra, Sakshi , Goodwin, Andrew , Audil, Hadiyah Y. , Ashrani, Aneel A. , Robinson, Nathaniel L. , Jones, Curtis G., Pechauer, Shannon M., yttre, erin , Kohlhagen, Mindy , Leger, Rachel, Murray, David , Pruthi, Rajiv K. , Pabmanabhan, Anand, Leung, Nelson , Tefera, Leben T. , Casanegra, Ana I. , Chen, Dong , Pabmanabhan, Anand

Blood | December 1, 2023 | Volume: 142 | Issue: Supplement 1 | Pages: 682-682

10.1182/blood-2023-181121 Get It

We identified a patient with a recently described syndrome, monoclonal gammopathy of thrombotic significance (MGTS; Blood. 2023 Apr 6;141(14):1772-1776), and three additional patients with high 4Ts scores who were consistently negative in the PF4-polyanion HIT ELISA (Lifecodes PF4 IgG, Immucor). The MGTS patient, with a monoclonal IgG kappa, had recurrent thrombosis, and transient mild thrombocytopenia (nadir in the low 100s) over a period of years, and was noted to have a HIT ELISA optical density (OD) of 0.117. The three HIT patients experienced thrombocytopenia and thrombosis with ELISA ODs of 0.37, 0.18 and 0.20. All patients were positive in platelet-activation (functional) testing demonstrating PF4 dependence and inhibited with both high concentrations of heparin (100U/mL) and the FcγRIIa blocking monoclonal antibody (mAb) IV.3, consistent with the presence of anti-PF4 antibodies in the patient samples ( data not shown). Because the serologic profile of these patients suggested a novel HIT subtype characterized by negative HIT ELISA results, we undertook a functional platelet assay screen of 500 consecutive HIT ELISA-negative patients tested in our diagnostic laboratory. Research studies were approved by the Institutional Review Board of Mayo Clinic. Of the 500 patients tested, 20 (4.0%) stimulated platelet activation in the PF4-dependent P-selectin Expression Assay (PEA ≥19%; data not shown). To exclude non-specific activation that can be induced by HLA antibodies, additional testing was performed to evaluate whether platelet activation was PF4-dependent using buffer or PF4-treated platelets. Three patients demonstrated PF4-dependent activation that was inhibited by high heparin concentrations and mAb IV.3, as would be expected for HIT antibodies (ELISA-negative HIT, EN-HIT1-3; Figure 1). On retrospective review, all three patients thus identified had clinical histories and courses consistent with high clinical probability for HIT. To develop tools to study this new class of antibodies, monoclonal HIT antibodies were generated in mice after PF4/heparin immunizations and screened using a novel approach that included simultaneous testing of hybridoma supernatants in the PEA and PF4-polyanion ELISA. This strategy was designed to enabled us to identify mAbs that activated platelets (in the PEA), but that did not bind antigenic targets in the HIT ELISA. A novel mAb 431.4 that was developed using this approach, and the well-characterized HIT-like mAb KKO were evaluated for their abilities to both bind PF4-polyanion targets in ELISA, and to activate PF4-treated platelets in the PEA (Figure 2). In significant contrast to KKO, mAb 431.4 did not bind PF4/polyanion complexes, however, like KKO, strongly activated platelets in a PF4-dependent manner. Activation induced by both KKO and mAb 431.4 was inhibited by high heparin concentrations, as would be expected for HIT antibodies. In vivo murine studies using this novel mAb are pending at this time. In summary, the non-canonical diagnostic profile of HIT ELISA-negative but platelet activation-positive antibodies were found at a relatively high incidence in HIT-suspected patients (0.6%; 3 of 500 ELISA-negative patients). These findings have important diagnostic/management implications and suggest a re-evaluation of ASH's HIT management guidelines as noted in recommendations 2.7 and 2.8 of that document (“In patients with an intermediate (Recommendation 2.7) or high (Recommendation 2.8)-probability 4Ts score and a negative immunoassay, the ASH guideline panel recommends discontinuation of the non-heparin anticoagulant and resumption of heparin, if indicated ”; Blood Adv (2018) 2 (22): 3360-3392). Figure 1. A subset of ELISA-negative HIT-suspected patients harbor anti-PF4 platelet-activating antibodies. Three ELISA-negative (EN) HIT patient samples from a screen of 500 samples demonstrate PF4-dependent platelet activation and inhibition with high heparin concentration and mAb IV.3 incubation. PBS, phosphate buffered saline; IC, isotype control; HDH- high dose heparin (100U/mL). Figure 2. Murine mAb 431.4 serologically mimics pathogenic ELISA-negative HIT/MGTS antibodies. ELISA and PEA testing was performed using the “HIT-like” mAb KKO, novel mAb 431.4, or an isotype control (IC) antibody. PVS-polyvinyl sulfonate (polyanion used in the Immucor IgG ELISA assay).