Back to Authors

Murray, David

Mayo Clinic

Mayo Clinic

Citations 3

Pathogenic PF4/Polyvinylsulfonate ELISA-negative Antibodies in HIT
Kanack, Adam J. , Splinter, Noah P., Mauch, Emily, Gil, Morayma Reyes , Jasra, Sakshi , Goodwin, Andrew , Smock, Kristi J. , Ahmad, Hadiyah, Ashrani, Aneel A. , Robinson, Nathaniel L. , Jones, Curtis G., Pechauer, Shannon M., yttre, erin , Aster, Richard H. , Kohlhagen, Mindy , Leger, Rachel, Murray, David, Zhou, Lu , Wang, Demin , Wen, Renren , Pruthi, Rajiv K. , Padmanabhan, Anand , Mauch, Emily E, Tefera, Leben, Kohlhagen, Mindy C, Leger, Rachel R, Wang, Demin , Tefera, Leben T. , Ahmad, Hadiyah, Casanegra, Ana I. , Jones, Curtis G., Chen, Dong

No container title available | November 6, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1101/2025.10.29.25338884 Get It

ABSTRACT BACKGROUND Platelet factor 4-polyanion enzyme-linked immunosorbent assays (ELISAs) are considered highly sensitive for diagnosing heparin-induced thrombocytopenia (HIT), such that current practice guidelines recommend use of ELISA-negative results to exclude HIT. Once HIT is ruled out, alternative, non-heparin-based anticoagulant treatments are ceased, and heparin reintroduction frequently occurs. METHODS Antigen-based and PF4-dependent functional testing were used to study PF4/polyvinyl sulfonate ELISA-negative platelet-activating antibodies in HIT-suspected patients and mice immunized with PF4/heparin. RESULTS Three patients with clinical presentations consistent with HIT tested negative in an ELISA using PF4-polyvinylsulfonate (PF4/PVS), an antigenic target very commonly used for HIT antibody detection. All three patients demonstrated PF4-dependent platelet activation in functional testing that was sensitive to blockade of platelet FcγRIIa receptors and inhibited by high concentrations of heparin, consistent with pathogenic HIT antibodies. Functional testing-based screening of 500 ELISA-negative patients identified three patients whose sera activated platelets in a PF4- and FcγRIIa-dependent manner, and had clinical histories consistent with HIT. Five of the six ELISA-negative HIT patients were re-exposed to heparin, which precipitated a decrease in platelet counts in all re-exposed patients, and one patient developed a new thrombus. To advance the study of ELISA-negative HIT antibodies, mice were immunized with PF4/heparin, and functional and antigenic assays were simultaneously used to successfully identify an ELISA-negative, PF4-dependent platelet-activating murine monoclonal antibody that recapitulated the serological characteristics of ELISA-negative HIT patients. CONCLUSIONS Recognition of ELISA-negative HIT is critical to avoid harm due to the cessation of alternative anticoagulation therapy and re-exposure of these patients to heparin.
Monoclonal Anti–Platelet Factor 4 Antibodies in Recurrent Pregnancy Loss
Bavli, Natalie , Kanack, Adam J. , Splinter, Noah P., Mauch, Emily, Kohlhagen, Mindy , Murray, David, Chen, Dong , Pruthi, Rajiv K. , Padmanabhan, Anand , Mauch, Emily E, Ainsworth, Alessandra J. , McBane, Robert D. , Kohlhagen, Mindy C, Padmanabhan, Anand , Nishimura, Yoshito , Sarode, Ravi

New England Journal of Medicine | July 16, 2025 | Volume: 393 | Issue: 3 | Pages: 306-309

10.1056/nejmc2506014 Get It

Implementation of a Mass Spectroscopic Method (Mass-Fix) to Replace Traditional Electrophoresis Methods for Patients with Monoclonal Gammopathies
Murray, David, Kohlhagen, Mindy , Coker, Jon, Dasari, Surendra , Willrich, Maria Alice V. , Dispenzieri, Angela

Blood | December 6, 2024 | Volume: 144 | Issue: Supplement 1 | Pages: 1953-1953

10.1182/blood-2024-204119 Get It

Background The detection, isotyping and quantitation of over-expressed immunoglobulin(s) (Igs) (M-protein) is key for diagnosing and monitoring patients with monoclonal gammopathies. Traditionally, our lab has used a combination of agarose gel protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE) for these purposes. In 2018, a mass spectrometric method (Mass-Fix) was implemented to replace IFE for M-protein isotyping. This work documents the validation of a quantitative version (Q-Mass-Fix) to replace both SPEP and IFE. Methods 24,645 samples submitted for M-protein testing between 7/2018 and 9/2023 with quantitative IgG, IgA and IgM measurements, Mass-Fix analysis and SPEP results were utilized for this study. A separate cohort of 100,000 M-protein negative samples were utilized to mathematically model the spectral shapes IgG, IgA and IgM polyclonal background. To detect M-proteins, software was developed that fits the polyclonal Ig portion of the spectra and M-proteins are detected as peaks above the polyclonal background. M-proteins isotypes are determined by matching similar peaks in spectra in 5 sperate immuno enrichments (IgG, IgA, IgM, kappa and lambda). M-protein quantitation was obtained by multiplying total M-protein isotype quantity by the fraction area of the M-protein in the spectra. M-protein dilutional studies were used to examine the linearity and level of detection of Q-Mass-Fix. Results SPEP and Q-Mass-Fix M-protein quantitation had the best agreement between the range of 10 to 40 g/L. Below 10 g/L, Q-Mass Fix had on average, lower M-protein values. Above 40 g/dL, Q-Mass-Fix values were on average, higher than SPEP. The automated isotyping assignment was 98.8 percent consistent with the isotype assigned by visual inspection. Dilutional studies revealed that Q-Mass-Fix quantitation was linear over a range of 70 to 0.04 g/L (slope 1.0, r2 0.99) with an analytical limit of quantitation of 0.1 g/L and a limit of detection of 0.04 g/L. Conclusion Q-Mass-Fix represents a significant improvement in comparison to our current SPEP method. Q-Mass-Fix is more capable of removing the interference of polyclonal Igs below 10 g/L and is not subjective to the dye saturation effect at high M-protein levels. The increased analytical measuring range and improved limit of detection of detection could be beneficial in tracking patient's response. Q-Mass Fix is more automated than SPEP and the workflow in our laboratory.