D-Dimer Reporting and Harmonization: Analysis of College of American Pathologists D-Dimer Proficiency Testing Program
Salazar, Eric, Smock, Kristi J. , Cazzolli, Taryn E, Dlott, Jeffrey S., Lickteig, Nathan, Long, Thomas A., Mulvey, J. Justin , Gil, Morayma Reyes, Rollins-Raval, Marian, Walker, Chance Avery, Zantek, Nicole D. , Goodwin, AJ, Zantek, Nicole D , Gil, Morayma Reyes , Rollins‐Raval, Marian A. , Teruya, Jun , Volod, Oksana , Walker, Chance, Wool, Geoffrey D.

Seminars in Thrombosis and Hemostasis | February 6, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/a-2803-3165 Get It

Abstract Measurement of D-dimer, a fibrin degradation product, is crucial for diagnosing thrombotic and fibrinolytic conditions. Despite its expanding utility, D-dimer testing faces challenges due to varying assay methodologies and nonstandardized reporting. To understand D-dimer reporting practices, the College of American Pathologists Hemostasis and Thrombosis Committee analyzed proficiency testing data from D-dimer surveys conducted between 2020 and 2023 across multiple laboratories. The data demonstrate that laboratories commonly report units that differ from the assay package insert when reporting their proficiency testing results. We sought to assess variability in reporting practices and opportunities for improvement in D-dimer reporting amongst participants. To accomplish this, we harmonized all D-dimer results to ng/mL fibrinogen equivalent units from one distributed sample and assessed distinct populations of entries per instrument/reagent combination. Notable trends emerged from this analysis. Data from laboratories using the same instrument/reagent combinations clustered around different means, suggesting issues with unit reporting and/or conversion. Entries reported in mg/L or ug/mL D-dimer units commonly exhibited significant deviations from the dominant population. For one instrument/reagent combination, most reported values differed by approximately twice the certificate of analysis value. This analysis highlights potential issues with D-dimer reporting in proficiency testing. Whether these issues translate into issues with clinical D-dimer reporting requires further study.
Interlaboratory Performance in Measurement of Dabigatran and Rivaroxaban
Goodwin, Andrew , Higgins, Russell A. , Long, Thomas , Chandler, Wayne L. , Harris, Neil , Isom, James , Moser, Karen , Olson, John D. , Smock, Kristi J. , VanSandt, Amanda M., Chen, Dong , Chen, Dong , Volod, Oksana , Rollins‐Raval, Marian A. , Pham, Huy P. , Wool, Geoffrey D.

Archives of Pathology & Laboratory Medicine | June 16, 2021 | Volume: 146 | Issue: 2 | Pages: 145-153

10.5858/arpa.2020-0633-cp Get It

Context.— Assessing direct oral anticoagulant (DOAC) drug levels by reliable laboratory assays is necessary in a number of clinical scenarios. Objective.— To evaluate the performance of DOAC-specific assays for various concentrations of dabigatran and rivaroxaban, assess the interlaboratory variability in measurement of these DOACs, and investigate the responsiveness of the routine clotting assays to various concentrations of these oral anticoagulants. Design.— College of American Pathologists proficiency testing survey data from 2013 to 2016 were summarized and analyzed. Results.— For dabigatran, the interlaboratory coefficient of variation (CV) of ecarin chromogenic assay was broad (ranging from 7.5% to 29.1%, 6.3% to 15.5%, and 6.8% to 9.0% for 100-ng/mL, 200-ng/mL, and 400-ng/mL targeted drug concentrations, respectively). The CV for diluted thrombin time for dabigatran was better overall (ranging from 11.6% to 17.2%, 9.3% to 12.3, and 7.1% to 11.2% for 100 ng/mL, 200 ng/mL, and 400 ng/mL, respectively). The rivaroxaban-calibrated anti-Xa assay CVs also showed variability (ranging from 11.5% to 22.2%, 7.2% to 10.9%, and 6.4% to 8.1% for 50-ng/mL, 200-ng/mL, and 400-ng/mL targeted drug concentrations, respectively). The prothrombin time (PT) and activated partial thromboplastin time (aPTT) showed variable dose- and reagent-dependent responsiveness to DOACs: PT was more responsive to rivaroxaban and aPTT to dabigatran. The undiluted thrombin time showed maximum prolongation across all 3 dabigatran concentrations, making it too sensitive for drug-level monitoring, but supporting its use as a qualitative screening assay. Conclusions.— DOAC-specific assays performed reasonably well. While PT and aPTT cannot be used safely to determine DOAC degree of anticoagulation, a normal thrombin time excludes the presence of dabigatran.
External Quality Assurance of Platelet Function Assays: Results of the College of American Pathologists Proficiency Testing Program
Chandler, Wayne L. , Brown, Alan F., Chen, Dong , Moser, Karen , Olson, John D. , Smock, Kristi J. , Volod, Oksana , Higgins, Russell A. , Pham, Huy Phu, Chen, Dong , Brown, Alan F., Pham, Huy P.

Archives of Pathology & Laboratory Medicine | December 21, 2018 | Volume: 143 | Issue: 4 | Pages: 472-482

10.5858/arpa.2017-0556-cp Get It

Context.— The College of American Pathologists (CAP) developed proficiency testing for platelet function assays by using blood collected by the participant added to challenge tubes containing either saline (normal) or tirofiban (abnormal). Objective.— To analyze platelet function proficiency testing for Platelet Function Analyzer PFA-100, platelet aggregation, PlateletWorks, and PlateletMapping. Design.— Proficiency testing data from 2012–2016 were analyzed. Results.— For PFA-100, a total of 1200 laboratories participated; the coefficient variation (CV) of cartridge closure times was 22% (saline); 44,952 of 45,616 survey responses (99%) provided an interpretation, and 42,934 of 44,952 (96%) were correct. For optical platelet aggregation, 190 laboratories participated; the CV was 17% (saline), 7444 of 7813 survey responses (95%) provided an interpretation, and 7015 of 7444 (94%) were correct. For PlateletWorks, 60 laboratories participated; the CV was 3% to 11% (saline); 2412 of 2454 survey responses (98%) provided an interpretation, and 1207 of 1276 (95%) were correct for adenosine diphosphate (ADP) and 936 of 1136 (82%) for collagen. For PlateletMapping, 200 laboratories participated. For ADP, 1128 of 2697 survey responses (42%) provided an interpretation, but only 927 of 1128 (82%) were correct. For arachidonic acid, 1139 of 2604 survey responses (44%) provided an interpretation and 964 of 1139 (85%) were correct. Conclusions.— CAP is the first to provide proficiency testing for platelet aggregation, PlateletWorks, and PlateletMapping. Platelet aggregation, PFA-100, and PlateletWorks using ADP as an agonist performed well with more than 90% of laboratories providing an interpretation and a similar number providing correct results. PlateletWorks using collagen and PlateletMapping showed worse interpretive accuracy than the other methods.
Issues Surrounding Age-Adjusted d-Dimer Cutoffs That Practicing Physicians Need to Know When Evaluating Patients With Suspected Pulmonary Embolism
Goodwin, Andrew , Higgins, Russell A. , Moser, Karen , Smock, Kristi J. , Chandler, Wayne L. , Kottke‐Marchant, Kandice, Hartman, Sarah K., Volod, Oksana , Brown, Alan F., Johari, Vandita, Burr, Sharon, Polyakov, Nataliya, Chen, Dong , Goodwin, Andrew J, Moser, Karen A, Johari, Vandita P, Chen, Dong , Brown, Alan F.

Annals of Internal Medicine | January 24, 2018 | Volume: 166 | Issue: 5 | Pages: 361-363

10.7326/m16-2030 Get It