Back to Authors

Wool, Geoffrey D.

https://orcid.org/0000-0002-3335-2905

Mayo Clinic

Medical College of Wisconsin

Citations 13

D-Dimer Reporting and Harmonization: Analysis of College of American Pathologists D-Dimer Proficiency Testing Program
Salazar, Eric, Smock, Kristi J. , Cazzolli, Taryn E, Dlott, Jeffrey S., Lickteig, Nathan, Long, Thomas A., Mulvey, J. Justin , Gil, Morayma Reyes, Rollins-Raval, Marian, Walker, Chance Avery, Zantek, Nicole D. , Goodwin, AJ, Zantek, Nicole D , Gil, Morayma Reyes , Rollins‐Raval, Marian A. , Teruya, Jun , Volod, Oksana , Walker, Chance, Wool, Geoffrey D.

Seminars in Thrombosis and Hemostasis | February 6, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/a-2803-3165 Get It

Abstract Measurement of D-dimer, a fibrin degradation product, is crucial for diagnosing thrombotic and fibrinolytic conditions. Despite its expanding utility, D-dimer testing faces challenges due to varying assay methodologies and nonstandardized reporting. To understand D-dimer reporting practices, the College of American Pathologists Hemostasis and Thrombosis Committee analyzed proficiency testing data from D-dimer surveys conducted between 2020 and 2023 across multiple laboratories. The data demonstrate that laboratories commonly report units that differ from the assay package insert when reporting their proficiency testing results. We sought to assess variability in reporting practices and opportunities for improvement in D-dimer reporting amongst participants. To accomplish this, we harmonized all D-dimer results to ng/mL fibrinogen equivalent units from one distributed sample and assessed distinct populations of entries per instrument/reagent combination. Notable trends emerged from this analysis. Data from laboratories using the same instrument/reagent combinations clustered around different means, suggesting issues with unit reporting and/or conversion. Entries reported in mg/L or ug/mL D-dimer units commonly exhibited significant deviations from the dominant population. For one instrument/reagent combination, most reported values differed by approximately twice the certificate of analysis value. This analysis highlights potential issues with D-dimer reporting in proficiency testing. Whether these issues translate into issues with clinical D-dimer reporting requires further study.
Pharmacogenomic Testing: Strategies and Technical Considerations for Clinical Laboratories
Ji, Yuan , Brunk, Lindsey, Bove, Betsy, Danyal, Karamatullah, Langman, Loralie J., Mot, Nicole, Mróz, Paweł , Natowicz, Marvin R. , Shirts, Brian, Smock, Kristi J. , Zhang, Bing , Moyer, Ann M. , Bove, Betsy, Mroz, Pawel, Reddi, Honey V. , Shirts, Brian, Wool, Geoffrey D.

Archives of Pathology & Laboratory Medicine | November 22, 2025 | Volume: 150 | Issue: 5 | Pages: 339-353

10.5858/arpa.2025-0179-cp Get It

Context.— Clinical laboratories are increasingly implementing pharmacogenomic (PGx) testing. Although PGx is similar to genetic testing for other indications, there are unique aspects that laboratories should consider. Objective.— To aid clinical laboratories that are implementing clinical PGx testing by describing characteristics of PGx test design and validation, as well as approaches to reporting. Resources that are useful for clinical laboratories performing PGx testing will be highlighted. Design.— The College of American Pathologists formed a workgroup composed of laboratorians with expertise in clinical PGx testing. The workgroup included representatives from the Association for Molecular Pathology and the American College of Medical Genetics and Genomics. The workgroup reviewed pertinent literature, as well as experience from proficiency testing and from members’ laboratories. Results.— The workgroup recommends that laboratories implementing PGx consider the following concepts: testing platform, test design (ie, selection of pharmacogenes and variants/alleles), use of reference materials during test development and as controls during clinical runs, star allele and standard nomenclature systems, translations from genotype to predicted phenotype, and considerations for result reporting including making medication recommendations. The workgroup provides considerations when using report vendors, emphasizing the clinical laboratory’s role and responsibility when implementing such reporting tools from vendors. Conclusions.— Clinical laboratories should be familiar with the fundamentals of PGx, ensure that PGx testing meets the applicable regulatory requirements for all aspects of the clinical laboratory testing process, and follow recommendations for standardization of nomenclature and reporting.
Karyotypic clonal fraction predicts adverse outcome in TP53 -mutated myeloid neoplasms: an International TP53 investigators Network (iTiN) study
Pandiri, M, Stengel, Anna , Shao, Haipeng , Velmurugan, S. , Jacob, Anisha, Symes, Emily , Kaur, Amandeep , Rojek, Alexandra E. , Sojitra, Payal , Wiredja, Danica , Chang, Hong , Patil, Esha, Patel, Jay , Patel, Ami B. , Pan, Zenggang , Findley, Anthony, Badar, Talha , Tariq, Hamza , Sallman, David A. , Bell, Robert , Perry, Anamarija M. , Fitzpatrick, Carrie , Pandiri, Madhavi , Zhou, Qianghua , Venkataraman, Girish , Badar, Talha , Rojek, Alexandra E , Zhang, Jingjing , Wang, Peng , Shao, Haipeng, Jacob, Anisha, Menon, Madhu P , Ghosh, Sharmila , Wool, Geoffrey D. , Arber, Daniel A. , Findley, Anthony, Haferlach, Claudia

Journal of Clinical Pathology | June 26, 2025 | Volume: 78 | Issue: 9 | Pages: 629-635

10.1136/jcp-2024-209954 Get It

We investigated the prognostic impact of blast counts, TP53 allelic state determinants (number of hits, del(17p), variant allele frequency, complex karyotype),and a novel karyotypic clonal cell fraction (≤50% clonal cells vs >50% clonal cells (termed ‘CK50’)) in 495 individuals with TP53- mutated ( TP53 MUT ) myeloid neoplasms. Outcome examined was 24-month survival (OS24). The cohort (median age 71) included 29% (144/495) myelodysplastic syndromes (MDS)/MDS-acute myeloid leukaemia (AML) (1%–19% blasts) and 71% (351/495) AML (≥20% blasts), with 18% (81/460) having low CK50. Overall, 83% received front-line hypomethylating agents. Higher blast counts (<20% vs ≥20%) were marginally associated with CK50 (p=0.08). In the OS24 analysis, blast count showed a marginal association with OS24 (HR 1.3 (95% CI 1.0 to 1.6); p=0.07), while CK50 predicted significantly inferior outcomes (HR=1.7 (95% CI 1.2 to 2.3); p=0.002). In a multivariable model including all TP53 allelic state determinants, only CK50 and complex karyotype remained relevant for predicting adverse outcomes.
Clonal Persistence of Anti-PF4 Antibodies in VITT Represents an MGTS-like State
Kanack, Adam J. , Mauch, Emily, Splinter, Noah P., George, Gemlyn , Smock, Kristi J. , Gundabolu, Krishna , Coker, Jon, Kohlhagen, Mindy , Murray, David , Pabmanabhan, Anand, Roberge, Guillaume , Wool, Geoffrey D. , Abou-Ismail, Mouhamed Yazan , Green, David L.

Blood | December 6, 2024 | Volume: 144 | Issue: Supplement 1 | Pages: 1227-1227

10.1182/blood-2024-208364 Get It

Background: Vaccine-induced immune thrombotic thrombocytopenia (VITT) is a severe thrombotic thrombocytopenia that predominantly occurs after adenoviral vector-based vaccines. VITT patients produce anti-platelet factor 4 (PF4) antibodies with restricted clonality (i.e., mono/oligoclonal) with lambda light chains. Long-term follow-up studies in VITT show a disconnect in the persistence of anti-PF4 antibodies, whereby ELISA-positive antibodies persist significantly longer than platelet-activating antibodies. The mechanistic basis of this is unclear and could be explained by a couple of hypotheses: (1) Epitope spreading where, with time, the specificity of platelet-activating anti-PF4 antibodies may “spread” to recognize only PF4 complexed to heparin vs. (2) Persistence of clonally restricted platelet-activating anti-PF4 antibodies which decrease in titers with time such that their levels are insufficient to crosslink platelet FcGRIIa and induce platelet activation. Methods: Acute, convalescent patient sera and affinity-purified anti-PF4 antibodies were evaluated in antigen-based, functional (platelet-activation-based), and mass spectrometry studies as previously described (Blood, 2022 Jul 7;140(1):73-77). The median time to last follow-up was 243 days after the acute episode (range: 114-664 days). Results: Follow-up samples were obtained from 6 VITT patients after Ad26.COV2.S vaccination. At last follow-up, anti-PF4 IgG antibodies reactive in PF4/polyanion ELISA were detected in the sera of 5/6 VITT patients. However, only one of these samples stimulated platelet activation in the PF4-dependent P-selectin expression assay (PEA; 199 days after acute presentation). Affinity-purified anti-PF4 antibodies were detected by ELISA in all follow-up samples and three of the six affinity-purified anti-PF4 antibody samples activated platelets in the PEA. Four of the six VITT patients demonstrated a monoclonal anti-PF4 antibody, while one each had a biclonal and triclonal profile. Five VITT patients produced IgG lambda light chain antibodies, while one produced an IgG kappa. All six VITT patients demonstrated synonymous anti-PF4 antibody profiles when comparing acute and follow-up antibody repertoires, without evidence of VITT patients producing new anti-PF4 antibodies after the acute episode. In all cases, levels of anti-PF4 antibodies were significantly lower in convalescent samples relative to acute samples. Given this data on the persistence of clonally-restricted VITT antibodies, samples from another VITT patient with thrombocytopenia (100-150,000/uL) persisting for more than three years were similarly evaluated. This patient, who experienced severe thrombosis after ChAdOx1 nCoV19 vaccination, demonstrated persistent ELISA and PEA positivity even three years after symptom onset but had not experienced breakthrough thrombosis while on anticoagulation therapy. Serum protein electrophoresis (SPEP) did not detect a monoclonal gammopathy. Anti-PF4 antibodies immuno-enriched from a sample obtained &gt;2 years after acute presentation demonstrated a monoclonal profile. While non-availability of an acute sample for anti-PF4 antibody characterization precluded a firm determination of whether this “Long VITT” case represented a subset of monoclonal gammopathy of thrombotic significance (MGTS; Blood 2023 Apr 6;141(14):1772-1776; New Eng J Med 2024 Aug 8), the chronicity of thrombocytopenia, presence of a monoclonal anti-PF4 antibody and persistently positive anti-PF4 serology supports this diagnosis. Conclusions. Clonally-restricted VITT antibodies persist for months-years with no evidence for the production of novel anti-PF4 antibodies after the acute event. Decreased abundance of anti-PF4 antibodies leads to negative functional results with follow up samples. Some platelet-activating antibodies can persist for very long periods (&gt;3 years) and mediate persistent thrombocytopenia, representing an SPEP-negative MGTS-like state. This study also demonstrates the first example of a VITT antibody with a kappa light chain. The requirement for anticoagulation in patients demonstrating ELISA-positive/functional test-negative results is not clear, but the persistence of mono/oligoclonal anti-PF4 antibodies raises the possibility for the upregulation of pathogenic antibody production in proinflammatory settings.
Cancer-Associated Venous Thromboembolic Disease, Version 2.2024, NCCN Clinical Practice Guidelines in Oncology
Streiff, Michael B. , Holmstrom, Bjorn, Angelini, Dana E. , Ashrani, Aneel A. , Diep, Robert , Fogerty, Annemarie E., Gallastegui, Nicolas , Gangaraju, Radhika , Rojas‐Hernandez, Cristhiam M. , Goldhaber, Samuel Z. , Kubal, Timothy, Leavitt, Andrew D., Mann, Janelle , Mantha, Simon , Morton, Colleen , Nester, Alex, O’Brien, Andrew , Ranade, M. , Salmasi, Amirali , Schaefer, Jordan K. , Williams, Eliot C., Wun, Theodore, Nguyen, Jamie , Freedman-Cass, Deborah A., Sliker, Bailee , Ashrani, Aneel, Schaefer, Jordan K , Buckner, Tyler W. , Fertrin, Kleber Yotsumoto , Ibrahim, Ibrahim , Leavitt, Andrew D. , Lim, Ming Y , Mann, Janelle, O’Brien, Andrew, Ortel, Thomas L. , Pine, Alexander B. , Pishko, Allyson M. , Wool, Geoffrey D. , Montgomery, Sarah E.

Journal of the National Comprehensive Cancer Network | September 5, 2024 | Volume: 22 | Issue: 7 | Pages: 483-506

10.6004/jnccn.2024.0046 Get It

The NCCN Guidelines for Cancer-Associated Venous Thromboembolic Disease provide strategies for the prevention, diagnosis, and treatment of venous thromboembolism (VTE) in adult patients with cancer. VTE is a common and life-threatening condition in patients with cancer, and its management often requires multidisciplinary efforts. The NCCN panel is comprised of specialists spanning various fields, including cardiology, hematology, medical oncology, internal medicine, interventional radiology, and pharmacology. The content featured in this issue specifically addresses the evaluation and recommended treatment options outlined in the NCCN Guidelines for the diverse subtypes of cancer-associated VTE.
Predictors of clinical outcome in myeloproliferative neoplasm, unclassifiable: A Bone Marrow Pathology Group study
Crane, Genevieve M. , Geyer, Julia T. , Wang, Sa A. , Li, Ke David, Davis, Adam R. , Bosler, David , Bueso‐Ramos, Carlos E. , Bagg, Adam , Hasserjian, Robert P. , Hsi, Eric D , Thakral, Beenu , Wool, Geoffrey D. , Boiocchi, Leonardo , Arber, Daniel A. , George, Tracy I. , Orazi, Attilio , Hsi, Eric D. , Rogers, Heesun J.

American Journal of Clinical Pathology | April 10, 2024 | Volume: 162 | Issue: 3 | Pages: 233-242

10.1093/ajcp/aqae033 Get It

Abstract Objectives Myeloproliferative neoplasm, unclassifiable (MPN-U, revised to MPN, not otherwise specified in the fifth edition of the World Health Organization classification) is a heterogeneous category of primary marrow disorders with clinical, morphologic, and/or molecular features that preclude classification as a more specific MPN subtype due to stage at diagnosis, overlapping features between MPN subtypes, or the presence of coexisting disorders. Compared with other MPN subtypes, the contribution of the mutational landscape in MPN-U in conjunction with other clinical and morphologic biomarkers to prognosis has been less well investigated. Methods We performed a multicenter, retrospective study of MPN-U (94 cases) to better define the clinicopathologic features, genetic landscape, and clinical outcomes, including subgroups of early-stage, advanced-stage, and coexisting disorders. The Dynamic International Prognostic Scoring System (DIPSS) plus scoring system was applied to assess its relevance to MPN-U prognosis. Results Multivariate analysis demonstrated bone marrow blast count and DIPSS plus score as statistically significant in predicting overall survival. Univariate analysis identified additional potential poor prognostic markers, including abnormal karyotype and absence of JAK2 mutation. Secondary mutations were frequent in the subset analyzed by next-generation sequencing (26/37 cases, 70.3%) with a borderline association between high molecular risk mutations and overall survival. Conclusions This study, as one of the largest of MPN-U studies incorporating both clinicopathologic and molecular data, moves toward identification of biomarkers that better predict prognosis in this heterogeneous category.
Analysis of College of American Pathologists von Willebrand Factor Proficiency Testing Program
Salazar, Eric , Long, Thomas A., Smock, Kristi J. , Harris, Neil Selwyn, Olson, John D. , Ritter, Jacob, Unold, David, VanSandt, Amanda M., Goodwin, Andrew , Wool, Geoffrey D. , Rollins‐Raval, Marian A. , Chen, Dong , Harris, Neil Selwyn, Chan, Clarence W. , Pham, Huy P.

Seminars in Thrombosis and Hemostasis | September 5, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0042-1757132 Get It

AbstractVon Willebrand factor (VWF) level and/or function is altered in von Willebrand disease (VWD), the most common heritable bleeding disorder worldwide. Laboratory assessment of VWF is continually evolving. Historically, the primary method for the assessment of VWF platelet-binding activity was the ristocetin cofactor assay (VWF:RCo). Contemporary alternative measures of VWF platelet-binding activity include VWF:GPIbR (recombinant; using ristocetin), VWF:GPIbM (recombinant; gain-of-function mutant), and monoclonal antibody. Recently, the American Society of Hematology, International Society on Thrombosis and Haemostasis, National Hemophilia Foundation, and World Federation of Hemophilia collaboration issued guidelines recommending the use of newer assays of VWF platelet-binding activity (VWF: GPIbM, VWF: GPIbR) over VWF:RCo, given known limitations of the VWF:RCo assay. Despite this recommendation, the newer VWF:GPIbM and VWF:GPIbR assays are not United States Food and Drug Administration cleared, limiting their availability in the United States. We sought to assess assay utilization trends, agreement of VWF testing methods, and imprecision of VWF testing (based on assigned sample type) from the College of American Pathologists Proficiency Testing Surveys. The analysis confirms that, while VWF antigen testing has low imprecision, the various VWF activity assays have significant interassay variability, with VWF:RCo showing greater imprecision than the newer GPIb-binding assays. The overall trends in assay utilization reflect the barriers to complete compliance with modern VWD diagnostic guidelines in North America.
Analysis of College of American Pathologists von Willebrand Factor Proficiency Testing Program
Salazar, Eric , Long, Thomas A., Smock, Kristi J. , Chen, Dong , Harris, Neil Selwyn, Olson, John D. , Ritter, Jacob, Unold, David, VanSandt, Amanda M., Goodwin, Andrew , Chen, Dong , Wool, Geoffrey D. , Rollins‐Raval, Marian A. , Harris, Neil Selwyn, Chan, Clarence W. , Pham, Huy P.

Seminars in Thrombosis and Hemostasis | September 2, 2022 | Volume: 48 | Issue: 06 | Pages: 690-699

10.1055/s-0042-1749591 Get It

AbstractVon Willebrand factor (VWF) level and/or function is altered in von Willebrand disease (VWD), the most common heritable bleeding disorder worldwide. Laboratory assessment of VWF is continually evolving. Historically, the primary method for the assessment of VWF platelet-binding activity was the ristocetin cofactor assay (VWF:RCo). Contemporary alternative measures of VWF platelet-binding activity include VWF:GPIbR (recombinant; using ristocetin), VWF:GPIbM (recombinant; gain-of-function mutant), and monoclonal antibody. Recently, the American Society of Hematology, International Society on Thrombosis and Haemostasis, National Hemophilia Foundation, and World Federation of Hemophilia collaboration issued guidelines recommending the use of newer assays of VWF platelet-binding activity (VWF: GPIbM, VWF: GPIbR) over VWF:RCo, given known limitations of the VWF:RCo assay. Despite this recommendation, the newer VWF:GPIbM and VWF:GPIbR assays are not United States Food and Drug Administration cleared, limiting their availability in the United States. We sought to assess assay utilization trends, agreement of VWF testing methods, and imprecision of VWF testing (based on assigned sample type) from the College of American Pathologists Proficiency Testing Surveys. The analysis confirms that, while VWF antigen testing has low imprecision, the various VWF activity assays have significant interassay variability, with VWF:RCo showing greater imprecision than the newer GPIb-binding assays. The overall trends in assay utilization reflect the barriers to complete compliance with modern VWD diagnostic guidelines in North America.
Off-the-shelf cryopreserved platelets for the detection of HIT and VITT antibodies
Kanack, Adam J. , Jones, Curtis G., Singh, Bandana, Leger, Rachel, Splinter, Noah P., Heikal, Nahla, Pruthi, Rajiv K. , Chen, Dong , George, Gemlyn , Gundabolu, Krishna , Padmanabhan, Anand , Leger, Rachel R, Heikal, Nahla M, Abou-Ismail, Mouhamed Yazan , Wool, Geoffrey , Gundabolu, Krishna , Padmanabhan, Anand , Chen, Dong , Wool, Geoffrey D.

Blood | August 23, 2022 | Volume: 140 | Issue: 25 | Pages: 2722-2729

10.1182/blood.2022017283 Get It

AbstractHeparin-induced thrombocytopenia (HIT) is suspected much more often than it is confirmed. Technically simple platelet factor 4 (PF4)-polyanion enzyme-linked immunosorbent assays (ELISAs) are sensitive but nonspecific. In contrast, accurate functional tests such as the serotonin release assay, heparin-induced platelet activation assay, and PF4-dependent P-selectin expression assay require fresh platelets and have complex assay end points, limiting their availability to specialized reference laboratories. To enable broad deployment of functional testing, we sought to extend platelet viability significantly by optimizing storage conditions and developed a simple functional assay end point by measuring the release of a platelet α-granule protein, thrombospondin-1 (TSP1), in an ELISA format. Platelet cryopreservation conditions were optimized by freezing platelets at controlled cooling rates that preserve activatability. Several-month-old cryopreserved platelets were treated with PF4 or heparin and were evaluated for their ability to be activated by HIT and vaccine-induced immune thrombotic thrombocytopenia (VITT) antibodies in the TSP1 release assay (TRA). HIT and spontaneous HIT patient samples induced significantly higher TSP1 release using both PF4-treated (PF4-TRA) and heparin-treated cryopreserved platelets relative to samples from patients suspected of HIT who lacked platelet-activating antibodies. This latter group included several patients that tested strongly positive in PF4-polyanion ELISA but were not platelet-activating. Four VITT patient samples tested in the TRA activated PF4-treated, but not heparin-treated, cryopreserved platelets, consistent with recent data suggesting the requirement for PF4-treated platelets for VITT antibody detection. These findings have the potential to transform the testing paradigm in HIT and VITT, making decentralized, technically simple functional testing available for rapid and accurate in-hospital diagnosis.
Persistence of Ad26.COV2.S‐associated vaccine‐induced immune thrombotic thrombocytopenia (VITT) and specific detection of VITT antibodies
Kanack, Adam J. , Singh, Bandana, George, Gemlyn , Gundabolu, Krishna , Koepsell, Scott A. , Moser, Karen , Smock, Kristi J. , Green, David , Major, Ajay , Ashrani, Aneel A. , Bayas, Antonios , Grill, Diane E. , Padmanabhan, Anand , Abou-Ismail, Mouhamed Yazan , Major, Ajay , Padmanabhan, Anand , Gundabolu, Krishna , Chan, Clarence W. , Wool, Geoffrey D. , Reding, Mark T.

American Journal of Hematology | February 8, 2022 | Volume: 97 | Issue: 5 | Pages: 519-526

10.1002/ajh.26488 Get It

AbstractRare cases of COVID‐19 vaccinated individuals develop anti‐platelet factor 4 (PF4) antibodies that cause thrombocytopenia and thrombotic complications, a syndrome referred to as vaccine‐induced immune thrombotic thrombocytopenia (VITT). Currently, information on the characteristics and persistence of anti‐PF4 antibodies that cause VITT after Ad26.COV2.S vaccination is limited, and available diagnostic assays fail to differentiate Ad26.COV2.S and ChAdOx1 nCoV‐19‐associated VITT from similar clinical disorders, namely heparin‐induced thrombocytopenia (HIT) and spontaneous HIT. Here we demonstrate that while Ad26.COV2.S‐associated VITT patients are uniformly strongly positive in PF4‐polyanion enzyme‐linked immunosorbent assays (ELISAs); they are frequently negative in the serotonin release assay (SRA). The PF4‐dependent p‐selectin expression assay (PEA) that uses platelets treated with PF4 rather than heparin consistently diagnosed Ad26.COV2.S‐associated VITT. Most Ad26.COV2.S‐associated VITT antibodies persisted for >5 months in PF4‐polyanion ELISAs, while the PEA became negative earlier. Two patients had otherwise unexplained mild persistent thrombocytopenia (140‐150 x 103/µL) 6 months after acute presentation. From an epidemiological perspective, differentiating VITT from spontaneous HIT, another entity that develops in the absence of proximate heparin exposure, and HIT is important, but currently available PF4‐polyanion ELISAs and functional assay are non‐specific and detect all three conditions. Here, we report that a novel un‐complexed PF4 ELISA specifically differentiates VITT, secondary to both Ad26.COV2.S and ChAdOx1 nCoV‐19, from both spontaneous HIT, HIT and commonly‐encountered HIT‐suspected patients who are PF4/polyanion ELISA‐positive but negative in functional assays. In summary, Ad26.COV2.S‐associated VITT antibodies are persistent, and the un‐complexed PF4 ELISA appears to be both sensitive and specific for VITT diagnosis.