Department of Cardiovascular Diseases Mayo Clinic Rochester MN.
Citations 38
Impact of Diagnosis to Ablation Time on Recurrence of Atrial Fibrillation and Clinical Outcomes After Catheter Ablation: A Systematic Review and Meta-Analysis With Reconstructed Time-to-Event Data
BACKGROUND: Current clinical guidelines emphasize the significance of rhythm control with catheter ablation but lack guidance on the timing of atrial fibrillation (AF) ablation relative to the diagnosis time. We aim to investigate the latest evidence on the impact of diagnosis to ablation time (DAT) on clinical outcomes after AF ablation. METHODS: We searched PubMed, Web of Science, Scopus, Embase, and Cochrane Central Register of Controlled Trials through August 2024. Pairwise, prognostic, and reconstructed time-to-event data meta-analyses were conducted using R V. 4.3.1. Our primary end point was time to first AF recurrence, with secondary end points of all-cause mortality, tamponade, stroke, and heart failure. RESULTS: Our cohort included 23 studies with 43 711 patients. Shorter DAT was significantly associated with reduced AF recurrence across both paroxysmal and persistent AF subgroups ( P <0.01). There was a significant decrease in benefit for paroxysmal AF over time and a slight decrease in benefit for persistent AF over time. However, the benefit remained significant in both over time. DAT per year was significantly associated with a 10% increased risk of AF recurrence. Reconstructed Kaplan-Meier analysis showed that DAT >1 year was significantly associated with a 70% increased risk of AF recurrence in paroxysmal AF and 30% in persistent AF. DAT ≤1 year was significantly associated with decreased all-cause mortality ( P <0.01) and showed a trend toward an association with a lower incidence of stroke ( P =0.08). However, there was no significant difference in heart failure between DAT ≤1 year and DAT >1 year. CONCLUSIONS: Early ablation is more beneficial in paroxysmal AF, with a notable decrease in benefit over time, while in persistent AF, the benefit remains significant but slightly decreases over time. Shorter DAT was significantly associated with decreased all-cause mortality and showed a trend toward an association with a lower incidence of stroke. REGISTRATION: URL: https://www.crd.york.ac.uk/prospero/display_record.php? ; Unique identifier: CRD42024525542.
Impact of Anemia on Clinical Outcomes in Atrial Fibrillation Patients on Oral Anticoagulants: A Prognostic Meta‐Analysis
ABSTRACTBackgroundAnemia is frequently observed as a comorbidity in atrial fibrillation (AF), especially in elderly patients and in those on anticoagulation. This has been associated with poor clinical outcomes. We aim to investigate the impact of anemia on clinical outcomes in patients with AF on oral anticoagulation.MethodsWe comprehensively searched PubMed, WOS, SCOPUS, EMBASE, and CENTRAL through March 2024 and conducted a prognostic systematic review and meta‐analysis. All analyses were performed using R V. 4.3.1. This meta‐analysis was registered at PROSPERO (CRD42024556023).ResultsWe included 23 studies comprising 286,781 patients for analysis. Anemia had a significant association with an 84% increase in risk of major bleeding (HR: 1.84 with 95% CI [1.59, 2.13], p < 0.01), a 32% increase in the risk of intracranial hemorrhage (HR: 1.32 with 95% CI [1.10, 1.58], p < 0.01), a 98% increase in the risk of gastrointestinal bleeding (HR: 1.98 with 95% CI [1.67, 2.35], p < 0.01), and a 91% increase in the risk of all‐cause mortality (HR: 1.91 with 95% CI [1.46, 2.51], p < 0.01). However, the impact of anemia did not significantly affect the risk of stroke, transient ischemic stroke (TIA), or systemic embolism (HR: 1.07 with 95% CI [0.93, 1.22], p = 0.36).ConclusionAnemia was significantly associated with an increased risk of major bleeding, intracranial hemorrhage, gastrointestinal bleeding, and all‐cause mortality. However, anemia did not significantly impact stroke, TIA, or systemic embolism.
Direct Comparison of Methods to Differentiate Wide Complex Tachycardias: Novel Automated Algorithms Versus Manual ECG Interpretation Approaches
BACKGROUND: Differentiating wide complex tachycardias (WCTs) into ventricular tachycardia (VT) and supraventricular wide tachycardia via 12-lead ECG interpretation is a crucial but difficult task. Automated algorithms show promise as alternatives to manual ECG interpretation, but direct comparison of their diagnostic performance has not been undertaken. METHODS: Two electrophysiologists applied 3 manual WCT differentiation approaches (ie, Brugada, Vereckei aVR, and VT score). Simultaneously, computerized data from paired WCT and baseline ECGs were processed by 5 automated WCT differentiation algorithms (WCT Formula, WCT Formula II, VT Prediction Model, Solo Model, and Paired Model). The diagnostic performance of automated algorithms was compared with manual ECG interpretation approaches. RESULTS: A total of 212 WCTs (111 VT and 101 supraventricular wide tachycardia) from 104 patients were analyzed. WCT Formula demonstrated superior accuracy (85.8%) and specificity (87.1%) compared with Brugada (75.2% and 57.4%, respectively) and Vereckei aVR (65.3% and 36.4%, respectively). WCT Formula II achieved higher accuracy (89.6%) and specificity (85.1%) against Brugada and Vereckei aVR. Performance metrics of the WCT Formula (accuracy 85.8%, sensitivity 84.7%, and specificity 87.1%) and WCT Formula II (accuracy 89.8%, sensitivity 89.6%, and specificity 85.1%) were similar to the VT score (accuracy 84.4%, sensitivity 93.8%, and specificity 74.2%). Paired Model was superior to Brugada in accuracy (89.6% versus 75.2%), specificity (97.0% versus 57.4%), and F1 score (0.89 versus 0.80). Paired Model surpassed Vereckei aVR in accuracy (89.6% versus 65.3%), specificity (97.0% versus 75.2%), and F1 score (0.89 versus 0.74). Paired Model demonstrated similar accuracy (89.6% versus 84.4%), inferior sensitivity (79.3% versus 93.8%), but superior specificity (97.0% versus 74.2%) to the VT score. Solo Model and VT Prediction Model accuracy (82.5% and 77.4%, respectively) was superior to the Vereckei aVR (65.3%) but similar to Brugada (75.2%) and the VT score (84.4%). CONCLUSIONS: Automated WCT differentiation algorithms demonstrated favorable diagnostic performance compared with traditional manual ECG interpretation approaches.
Association between COVID‐19 vaccination and atrial arrhythmias in individuals with cardiac implantable electronic devices
AbstractIntroductionThe impact of mRNA‐based coronavirus disease‐2019 (COVID‐19) vaccines on atrial arrhythmias (AA) and ventricular arrhythmias incidence is unknown.MethodsBIOTRONIK Home Monitoring data and Medicare Claims data were utilized to identify individuals implanted with a cardiac implantable electronic device (CIED) between 2010 and 2020 who received one or more doses of COVID‐19 vaccine in 2021. The burden of AA (%) in the 3 months postvaccination was compared to those noted in the preceding 3 months using the Wilcoxon signed rank test. Sub‐analyses comparing the effects of the influenza vaccine against the COVID‐19 vaccine were also evaluated for individuals who received the influenza vaccine in 2020. A 1:1 propensity score match comparison between COVID‐19 vaccine and non‐vaccinated patients was also performed.ResultsFirst and second doses of the COVID‐19 vaccine were administered to 7757 and 6579 individuals with a CIED (age 76.2 ± 9.0 years, 49% males), respectively. While a small but statistically significant increase in the burden of AA was noted in the 3 months postvaccination compared to the preceding 3 months after the first dose of the COVID‐19 vaccine (0.43 ± 9.04%, p = .028) a similar rise in AA was found following the influenza vaccine and for matched patients who did not receive the COVID‐19 vaccine. No significant difference in device therapies was seen pre‐ and postvaccination.ConclusionsThough we report a small but significant increase in the number of CIED‐detected AAs following vaccination for COVID‐19 over a 3‐month window, we believe these results correlate more with time and the progressive nature of AF rather than the vaccine itself. While these data should not dissuade from the use of these vaccines, increased vigilance and prompt treatment of AF is required for high‐risk groups, specifically males over 70 years of age, following vaccination.
Trends and disparities in cardiac implantable electronic device infection‐related mortality in the United States
AbstractIntroductionWe performed a cross‐sectional study using the Centers for Disease Control and Prevention's (CDC's) Wide‐Ranging Online Data for Epidemiologic Research (WONDER) database to analyze the trends in cardiac implantable electronic device (CIED) infection‐related mortality from 1999 to 2020.MethodsWe analyzed the death certificate data from the CDC WONDER database from 1999 to 2020 for CIED infections in the US population aged ≥25 years using International Classification of Diseases, Tenth Revision (ICD‐10) codes, listed as the underlying or contributing cause of death. Age‐adjusted mortality rates (AAMR) and 95% confidence intervals (CIs) were computed per 1 million population by standardizing crude mortality rates to the 2000 US census population. To assess annual mortality trends, we employed the Joinpoint regression model, calculating the annual percent change (APC) in AAMR and corresponding 95% CIs.ResultsOverall, there was an observed declining trend in AAMRs related to CIED infection‐related mortality. Males accounted for 55% of the total deaths, with persistently higher AAMRs compared to females over the study duration. Both males and females had an overall decreasing trend in AAMRs throughout the study duration. On race/ethnicity stratified analysis, non‐Hispanic (NH) Blacks exhibited the highest overall AAMR, followed by NH American Indians or Alaska Natives, NH Whites, Hispanic or Latinos, and NH Asian or Pacific Islanders. On a stratified analysis based on region, the South region had the highest overall AAMR, followed by the Midwest, West, and Northeast regions.ConclusionOur study demonstrates a significant decline in CIED infection‐related mortality in patients over the last two decades. Notable gender, racial/ethnic, and regional differences exist in the rates of mortality related to CIED infections.
Electrical storm after left ventricular assist device (LVAD) implantation
AbstractIntroductionVentricular tachycardia storm or electrical storm (ES) is a common complication following left ventricular assist device (LVAD) implantation. The factors contributing to ES and outcomes are less studied. The study aimed to determine the factors associated with ES and the probability of survival in patients undergoing LVAD in three tertiary centers over a span of 15 years.MethodsWe performed a retrospective cohort study on all patients who underwent LVAD implantation at the Mayo Clinic (Rochester, Phoenix, and Jacksonville) from January 1, 2006 to December 31, 2020. ES was defined as ≥3 episodes of sustained ventricular tachycardia over a period of 24 h with no identifiable reversible cause. Detailed chart reviews of the electronic health records within the Mayo Clinic and outside medical records were performed.ResultsA total of 883 patients who underwent LVAD implantation were included in our study. ES occurred in 7% (n = 61) of patients with a median of 13 days (interquartile range [IQR]: 5–297 days) following surgery. We found 57% of patients (n = 35) developed ES within 30 days, while 43% (n = 26) patients developed ES at a median of 545 (IQR 152–1032) days after surgery. Following ES, 26% of patients died within 1 year. Patients with ES had a significant association with a history of ventricular arrhythmias and implantable cardioverter defibrillator (ICD) shocks before the procedure. ES was significantly associated with reduced survival compared to patients without ES (hazards ratio [HR]: 1.92, 95% CI: 1.39–2.64, p < .001).ConclusionFollowing LVAD implantation, the rate of ES was 7% with majority of ES occurring within 30 days of LVAD. Risk factors for ES included pre‐implant history of ventricular arrhythmias and ICD shock. ES was significantly associated with reduced survival compared to patients without ES.
Single-dose Intraoperative Steroid Administration Does Not Impact Early Atrial Fibrillation Recurrence
Background: Inflammation is integral in the pathogenesis and propagation of atrial fibrillation (AF). Peri-ablation administration of steroids has been shown to significantly reduce AF recurrence at 3 months. We sought to determine the effect of intraoperative dexamethasone on early recurrence at both 3 months and 12 months post-ablation. Methods: A cohort of 94 adult patients (>18 years) underwent catheter ablation at Mayo Clinic Rochester from January to March 2019. Only first-time ablation patients were included, with all re-do ablations excluded to minimize heterogeneity. Administration of intraoperative dexamethasone 4 mg or 8 mg was determined by chart review from the procedure. At our institution, intraoperative intravenous steroids are administered for postoperative nausea and vomiting (PONV) prophylaxis at the discretion of the anesthesiologist. AF recurrence was determined by ECG or cardiac monitoring at less than 3 months or between 3 months and 1 year with an in-person follow-up visit. Results: A total of 36.2% of patients received intravenous dexamethasone compared to 63.8% who did not (providing a 2:1 comparison group). The incidence of documented AF or flutter lasting greater than 30 seconds was 20.6% in the dexamethasone group versus 21.7% in the non-dexamethasone group, p value 1.00. AF or atrial flutter recurrence from 3 months to 1 year was 20.6% in the dexamethasone group compared to 21.7% in the non-dexamethasone group, p value 1.00. Conclusion: These data suggest that intraoperative intravenous dexamethasone administered during AF ablation for postoperative nausea and vomiting prophylaxis does not have a significant effect on AF recurrence rates.
The effect of weight loss on recurrence of atrial fibrillation after catheter ablation: A systematic review and meta‐analysis
Abstract Background Obesity is associated with an increased risk of developing recurrent atrial fibrillation (AF) after catheter ablation (CA). However, the current data on weight loss interventions show inconsistent results in preventing the recurrence of AF after CA. Methods We conducted a systematic search in MEDLINE and EMBASE to identify studies that reported the outcome of recurrence of AF after CA in obese patients undergoing weight interventions. The subgroup analysis included: (1) Weight loss versus no weight loss, (2) >10% weight loss versus <10% weight loss, (3) <10% weight loss versus no weight loss, (4) Follow‐up <12 months, and (5) Follow‐up >12 months after CA. Mantel–Haenszel risk ratios with a 95% confidence interval (CI) were calculated using a random effects model and for heterogeneity, I 2 statistics were reported. Results A total of 10 studies (one randomized controlled trial and nine observational studies) comprising 1851 patients were included. The recurrence of AF was numerically reduced in the weight loss group (34.5%) versus no weight loss group (58.2%), but no statistically significant difference was observed (risk ratio [RR] = 0.76; 95% CI: 0.49–1.18, p = .22). However, there was a statistically significant reduction in recurrence of AF with weight loss versus no weight loss at follow‐up >12 months after CA (RR = 0.47; 95% CI: 0.32–0.68, p < .0001). At follow‐up >12 months after CA, both >10% weight loss versus <10% weight loss (RR = 0.49; 95% CI: 0.31–0.80, p = .004) and <10% weight loss versus no weight loss (RR = 0.39; 95% CI: 0.31–0.49, p < .00001) were associated with a statistically significant reduction in recurrent AF. Conclusion In patients with AF undergoing CA, weight loss is associated with reducing recurrent AF at > 12 months after ablation and these benefits are consistently seen with both >10% and <10% weight loss. The benefits of weight loss in preventing recurrent AF after CA should be examined in larger studies with extended follow‐up duration.
Same‐day discharge for left atrial appendage occlusion procedure: A systematic review and meta‐analysis
AbstractIntroductionMost patients undergoing a left atrial appendage occlusion (LAAO) procedure are admitted for overnight observation. A same‐day discharge strategy offers the opportunity to improve resource utilization without compromising patient safety. We compared the patient safety outcomes and post‐discharge complications between same‐day discharge versus hospital admission (HA) (>1 day) in patients undergoing LAAO procedure.MethodsA systematic search of MEDLINE and Embase was conducted. Outcomes of interest included peri‐procedural complications, re‐admissions, discharge complications including major bleeding and vascular complications, ischemic stroke, all‐cause mortality, and peri‐device leak >5 mm. Mantel–Haenszel risk ratios (RRs) with 95% CIs were calculated.ResultsA total of seven observational studies met the inclusion criteria. There was no statistically significant difference between same‐day discharge versus HA regarding readmission (RR: 0.61; 95% confidence interval [CI]: [0.29–1.31]; p = .21), ischemic stroke after discharge (RR: 1.16; 95% CI: [0.49–2.73]), peri‐device leak >5 mm (RR: 1.27; 95% CI: [0.42–3.85], and all‐cause mortality (RR: 0.60; 95% CI: [0.36–1.02]). The same‐day discharge study group had significantly lower major bleeding or vascular complications (RR: 0.71; 95% CI: [0.54–0.94]).ConclusionsThis meta‐analysis of seven observational studies showed no significant difference in patient safety outcomes and post‐discharge complications between same‐day discharge versus HA. These findings provide a solid basis to perform a randomized control trial to eliminate any potential confounders.
Effects of Pulsed Electric Fields on the Coronary Arteries in Swine
Background: Previous animal studies have shown no significant vascular injury from pulsed electrical field (PEF) ablation. We sought to assess the effect of PEF on swine coronary arteries. Methods: We performed intracoronary and epicardial (near the coronary artery) PEF ablations in swine pretreated with dual antiplatelet and antiarrhythmic therapy. Intracoronary PEF was delivered using MapiT catheters (Biotronik, Berlin), whereas epicardial PEF was delivered using EPT catheters (Boston Scientific, MA). PEF pulse duration was microseconds (Nanoknife 3.0, Angio Dynamics, NY) or nanoseconds (CellFX, Pulse Biosciences, CA). Results: We performed 39 intracoronary ablations in 10 swine and 20 epicardial-pericoronary ablations in 4 separate swine. Intracoronary PEF was delivered at higher energy compared with epicardial PEF (46 [interquartile range, IQR 20–85] J versus 10 [IQR 10–11] J, P < 0.01). Reversible coronary spasm occurred in 49% intracoronary ablations and 45% epicardial ablations ( P =0.80). At the end study, fixed coronary stenosis was demonstrated in 44% intracoronary ablations (80% for microsecond PEF and 18% for nanosecond PEF) and 0% epicardial ablations. Visible hemorrhagic and/or fibrotic myocardial lesions were observed at necropsy with similar frequency between intracoronary and epicardial PEF (45% versus 50%, P =0.70). Nanosecond PEF (49 ablations in 11 swine), when compared with microsecond PEF (10 intracoronary ablations in 3 swine), resulted in lower energy delivery (21 [IQR 10–46] J versus 129 [IQR 24–143] J, P =0.03) and less incidence of fixed coronary stenosis (18% versus 80%, P =0.04). Conclusions: In the swine model, intracoronary PEF resulted both in significant coronary spasm and fixed coronary stenosis. Epicardial PEF, delivered at lower energy, resulted in reversible spasm but no fixed coronary stenosis.