Back to Authors

Friedman, Paul A

0000-0001-5052-2948

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, MN (Z.I.A., J.W., K.M., P.A.F., P.A.N.).

Citations 50

Mineralocorticoid Receptor Antagonism Reduces Atrial Arrhythmias Post-Cardiac Surgery and Attenuates Atrial Stress Responses to Cardioplegic Arrest
Danesh, Sina , Khan, Fazal , Lee, Aurora , Huo, Ran , Shuyang, Lu, Tam, Vincy, Safi, J. Pedro , Maleszewski, Joseph J. , Friedman, Paul A. , Oral, Hakan , Metra, Marco , Pitt, Bertram, Safi, Pedro Fincatto , Pagani, Francis D , Maleszewski, Joseph J , Schaff, Hartzell , Friedman, Paul A , Oral, Hakan , Pitt, Bertram , Tang, Paul C , Khan, Fazal Wahab , Metra, Marco , Chopko, Trevor C. , Huo, Ran, Tam, Vincy , Gao, Wenbin , Todd, Austin, Pagani, Francis D. , Schaff, Hartzell V. , Lei, Ienglam , Tang, Paul C.

No container title available | February 28, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1101/2025.02.24.639999 Get It

Abstract Background New postoperative atrial fibrillation (POAF) occurs in about 40% after cardiac surgery. Mineralocorticoid receptor antagonists (MRA) are known to reduce chronic atrial fibrillation (AF) development and burden. We examined the impact of preoperative MRA use on POAF and also examine the atrial cell type impacted by MRA treatment during cold cardiac preservation. Methods Retrospective study of 19,042 patients who underwent cardiac surgery at Mayo Clinic in Minnesota, and performed 1:3 propensity matching to obtain 298 patients on preoperative MRA matched to 894 who were not. We also separately matched patients using preoperative diuretics. Single-nuclei RNA sequencing (snRNA-seq) examined MRA’s effects on different atrial cell types in canrenone (water soluble MRA) treated human donor hearts undergoing cold preservation followed by ex-vivo reperfusion and compared gene expression to the atria of patients with AF. Results Propensity matched preoperative MRA group had less new onset POAF (19.8% vs 31.5%, P<0.001). To account for the possibility that preoperative diuretic use and volume reduction may impact POAF, we propensity matched 298 preop diuretic users that included MRA use to another 894 patients who used a non-MRA diuretic preoperatively. Those who used preoperative MRA similarly had a lower incidence of POAF (19.8% vs 33.2%, P<0.001). No survival difference was present between the propensity matched groups that used preoperative diuretics (P=0.079). Preoperative MRA use also reduced the development of paroxysmal and chronic AF at 6 years of follow up. From our snRNA-seq data, we identified a subpopulation of atrial cardiomyocytes (CM2) that had high MR expression where canrenone suppressed the increase in MR target gene expression associated with cold preservation-reperfusion. These MR targets were conversely elevated in patients with chronic AF. Canrenone also suppressed other cardiac preservation associated genes that show elevated expression in atrial macrophages and pericytes from chronic AF atria. Conclusions Our studies show that preoperative MRA use is associated with 40% reduction in POAF as well as lowering long standing AF development by about 41%. Our cold cadiac preservation-reperfusion model showed that canrenone reduced expression of MR target genes associated with chronic AF, particular in cardiomyocytes with important roles in electrical conduction. Clinical Perspective What is New? This study shows that preoperative use of mineralocorticoid receptors antagonists (MRA) is associated with a reduced incidence of new onset perioperative atrial fibrillation after cardiac surgery utilizing cardiopulmonary bypass. We show that preoperative MRA use is associated with a lower incidence of developing more chronic paroxymal or sustained atrial fibrillation. Addition of canrenone, a clinically utilized water soluble MRA, to cardioplegia solution used during cardiac preservation can attenuate atrial inflammatory reponses and reduce signaling through molecular pathways that promote atrial fibrillation. What are the clinical implications? Perioperative use of MRAs may be considered to reduce early postoperative atrial fibrillation as well as lowering the risk of developing more chronic atrial arrhythmias. These findings support pursuing a clinical trial to determine the impact of MRA use on atrial arrhythmias following cardiac surgery in the setting of cardiopulmonary bypass with cold cardiac preservation.
Artificial Intelligence ECG Diastolic Dysfunction and Survival in Cardiac Intensive Care Unit Patients
Jentzer, Jacob C. , Lee, Eunjung , Attia, Zachi I. , Kane, Garvan C. , López-Jiménez, Francisco , Noseworthy, Peter A. , Friedman, Paul A. , Oh, Jae K. , Attia, Zachi I , Hillerson, Dustin , Lopez-Jimenez, Francisco , Noseworthy, Peter A , Friedman, Paul A , Oh, Jae K. , Jentzer, Jacob C

Journal of the American Heart Association | February 19, 2025 | Volume: 14 | Issue: 5 | Pages: No page available

10.1161/jaha.124.037839 Get It

Background Left ventricular diastolic dysfunction (LVDD) predicts mortality in patients in cardiac intensive care units. An artificial intelligence enhanced ECG (AIECG) algorithm can predict LVDD and mortality in general populations but has not been examined in cardiac intensive care units. Methods This historical cohort study included consecutive adults admitted to Mayo Clinic cardiac intensive care unit from 2007 to 2018 with an admission AIECG. The AIECG assigned the LVDD grade (0–3). Medial mitral E/e' ratio >15 on transthoracic echocardiogram (TTE) defined elevated filling pressures. In‐hospital and 1‐year mortality was evaluated, before and after multivariable adjustment. Results We included 11 868 patients (median age 69.5 years, 37.7% female); 48% had heart failure and 44% had acute coronary syndromes. AIECG LVDD grade was 0 (normal), 33%; 1, 7%; 2, 39%; and 3, 21%. In‐hospital and 1‐year mortality increased in each higher AIECG LVDD grade. After adjustment, each higher AIECG LVDD grade was associated with higher in‐hospital (adjusted odds ratio [OR], 1.22 [95% CI, 1.13–1.32]) and 1‐year mortality (adjusted hazard ratio [HR], 1.23 [95% CI, 1.19–1.29]); this persisted after adjustment for TTE measurements. Patients with grade 2 or 3 LVDD by AIECG and medial mitral E/e' ratio >15 by TTE had the highest in‐hospital (adjusted OR, 2.54 [95% CI, 1.69–3.88]) and 1‐year (adjusted HR, 2.03 [95% CI, 1.65–2.48]) mortality, whereas patients meeting either of these criteria had similar, elevated mortality. Conclusions The AIECG LVDD grade was strongly associated with in‐hospital and 1‐year mortality in patients in cardiac intensive care units, even after adjusting for clinical variables and TTE measurements. Patients with concordant AIECG and TTE for elevated filling pressures were at highest risk.
Artificial intelligence–derived electrocardiographic aging and risk of atrial fibrillation: a multi-national study
Cho, Seunghoon , Eom, Sujeong , Kim, Daehoon , Kim, Tae‐Hoon , Uhm, Jae‐Sun , Pak, Hui‐Nam , Lee, Moon‐Hyoung , Yang, Pil‐Sung , Lee, Eunjung , Attia, Zachi I. , Friedman, Paul A. , You, Seng Chan , Yu, Hee Tae , Joung, Boyoung , Attia, Zachi I , Friedman, Paul A , Joung, Boyoung

European Heart Journal | December 3, 2024 | Volume: 46 | Issue: 9 | Pages: 839-852

10.1093/eurheartj/ehae790 Get It

Abstract Background and Aims Artificial intelligence (AI) algorithms in 12-lead electrocardiogram (ECG) provides promising age prediction methods. This study investigated whether the discrepancy between ECG-derived AI-predicted age (AI-ECG age) and chronological age, termed electrocardiographic aging (ECG aging), is associated with atrial fibrillation (AF) risk. Methods An AI-ECG age prediction model was developed using a large-scale dataset (1 533 042 ECGs from 689 639 participants) and validated with six independent and multi-national datasets (737 133 ECGs from 330 794 participants). The AI-ECG age gap was calculated across two South Korean cohorts [mean (standard deviation) follow-up: 4.1 (4.3) years for 111 483 participants and 6.1 (3.8) years for 37 517 participants], one UK cohort [3.0 (1.6) years; 40 973 participants], and one US cohort [12.9 (8.6) years; 90 639 participants]. Participants were classified into two groups: normal group (age gap &lt; 7 years) and ECG-aged group (age gap ≥ 7 years). The predictive capability of ECG aging for new- and early-onset AF risk was assessed. Results The mean AI-ECG ages were 51.9 (16.2), 47.4 (12.5), 68.4 (7.8), and 56.7 (14.6) years with age gaps of .0 (6.8), −.1 (6.0), 4.7 (8.7), and −1.4 (8.9) years in the two South Korean, UK, and US cohorts, respectively. In the ECG-aged group, increased risks of new-onset AF were observed with hazard ratios (95% confidence intervals) of 2.50 (2.24–2.78), 1.89 (1.46–2.43), 1.90 (1.55–2.33), and 1.76 (1.67–1.86) in the two South Korean, UK, and US cohorts, respectively. For early-onset AF, odds ratios were 2.89 (2.47–3.37), 1.94 (1.39–2.70), 1.58 (1.06–2.35), and 1.79 (1.62–1.97) in these cohorts compared with the normal group. Conclusions The AI-derived ECG aging was associated with the risk of new- and early-onset AF, suggesting its potential utility to identify individuals for AF prevention across diverse populations.
Artificial intelligence evaluation of electrocardiographic characteristics and interval changes in transgender patients on gender-affirming hormone therapy
Adel, Fadi , Sang, Philip, Walsh, Connor , Maheshwari, Arvind , Cummings, Paige , Mangold, Kathryn, Davidge‐Pitts, Caroline , López-Jiménez, Francisco , Friedman, Paul A. , Adel, Fadi W , Davidge-Pitts, Caroline , Lopez-Jimenez, Francisco , Friedman, Paul A , Mankad, Rekha , Attia, Zachi I. , Noseworthy, Peter A. , Mankad, Rekha

European Heart Journal - Digital Health | October 15, 2024 | Volume: 6 | Issue: 1 | Pages: 55-62

10.1093/ehjdh/ztae076 Get It

Abstract Aims Gender-affirming hormone therapy (GAHT) is used by some transgender individuals (TG), who comprise 1.4% of US population. However, the effects of GAHT on electrocardiogram (ECG) remain unknown. The objective is to assess the effects of GAHT on ECG changes in TG. Methods and results Twelve-lead ECGs of TG on GAHT at the Mayo Clinic were inspected using a validated artificial intelligence (AI) algorithm. The algorithm assigns a patient’s ECG male pattern probability on a scale of 0 (female) to 1 (male). In the primary analysis, done separately for transgender women (TGW) and transgender men (TGM), 12-lead ECGs were used to estimate the male pattern probability before and after GAHT. In a subanalysis, only patients with both pre- and post-GAHT EGCs were included. Further, the autopopulated PR, QRS, and QTc intervals were compared before and after GAHT. Among TGW (n = 86), the probability (mean ± SD) of an ECG male pattern was 0.84 ± 0.25 in the pre-GAHT group, and it was lowered to 0.59 ± 0.36 in the post-GAHT group (n = 173, P &lt; 7.8 × 10−10). Conversely, among TGM, male pattern probability was 0.16 ± 0.28 (n = 47) in the pre-GAHT group, and it was higher at 0.41 ± 0.38 in the post-GAHT group (n = 53, P &lt; 2.4×10−4). The trend persisted in the subanalysis. Furthermore, both the PR (P = 5.68 × 10−4) and QTc intervals (P = 6.65×10−6) prolonged among TGW. Among TGM, the QTc interval shortened (P = 4.8 × 10−2). Conclusion Among TG, GAHT is associated with ECG changes trending towards gender congruence, as determined by the AI algorithm and ECG intervals. Prospective studies are warranted to understand GAHT effects on cardiac structure and function.
Performance and Safety of the Extravascular Implantable Cardioverter Defibrillator Through Long-Term Follow-Up: Final Results From the Pivotal Study
Friedman, Paul A. , Murgatroyd, Francis , Boersma, Lucas V.A. , Manlucu, Jaimie , Knight, Bradley P. , Leclercq, Christophe , Amin, Anish K. , Birgersdotter‐Green, Ulrika , Chan, Joseph Yat Sun , Engel, Gregory , Carvajal, Ignacio Muñoz , Sagi, Venkata, Johansen, Jens Brock , Steinwender, Clemens , Hounshell, Troy , Abben, Richard, Thompson, Amy , Wiggenhorn, Christopher, Willey, Sarah, Investigators, on behalf of the Extravascular ICD Pivotal Study, Friedman, Paul A , Leclercq, Christophe , Merkely, Béla , Birgersdotter-Green, Ulrika Maria , Chan, Joseph Yat Sun , Biffi, Mauro , Knops, Reinoud Elwin , Muñoz Carvajal, Ignacio , Epstein, Laurence M , Johansen, Jens Brock , Sterliński, Maciej , Steinwender, Clemens , Hounshell, Troy , Abben, Richard , Thompson, Amy E , Crozier, Ian , Knight, Bradley P , Boersma, Lucas , Clémenty, Nicolas , Biffi, Mauro , Engel, Gregory, Epstein, Laurence M. , Zhang, Yan , Crozier, Ian , Investigators, on behalf of the Extravascular ICD Pivotal Study

Circulation | September 27, 2024 | Volume: 151 | Issue: 4 | Pages: 322-332

10.1161/circulationaha.124.071795 Get It

BACKGROUND: Substernal lead placement of the extravascular implantable cardioverter defibrillator (EV ICD) permits both defibrillation at thresholds similar to those seen with transvenous implantable cardioverter defibrillators and effective anti-tachycardia pacing (ATP) while avoiding the vasculature and associated complications. The global Pivotal study has shown the EV ICD system to be safe and effective through 6 months, but long-term experience has yet to be published. Our aim was to report the performance and safety of the EV ICD system throughout the study. METHODS: The EV ICD Pivotal study was a prospective, global, single-arm, premarket clinical study. Individuals with a Class I or IIa indication for a single-chamber implantable cardioverter defibrillator per guidelines were enrolled. Freedom from major system- or procedure-related complications and appropriate and inappropriate therapy rates were assessed through 3 years with the Kaplan-Meier method. ATP success was calculated from simple proportions. RESULTS: An implantation was attempted in 316 patients (25.3% female; 53.8±13.1 years of age; 81.6% primary prevention; left ventricular ejection fraction, 38.9±15.4%). Of 299 patients with a successful implantation, 24 experienced 82 spontaneous arrhythmic episodes that were appropriately treated with ATP only (38, 46.3%), shock only (34, 41.5%), or both (10, 12.2%) for a Kaplan-Meier–estimated rate of first any appropriate therapy of 9.2% at 3 years. ATP was successful in 77.1% (37/48) of episodes, and ATP use significantly increased from discharge to last follow-up visit ( P <0.0001). Shock therapy was successful in 100% (27/27) of discrete, spontaneous ventricular arrhythmias. The inappropriate shock rates at 1 and 3 years were 9.8% and 17.5%, respectively, with P-wave oversensing the predominant cause. No major intraprocedural complications were reported, and the estimated freedom from system- or procedure-related major complications was 91.9% at 1 year and 89.0% at 3 years. The most common major complications were lead dislodgement (10 events; n=9 patients, 2.8%), postoperative wound or device pocket infection (n=8, 2.5%), and device inappropriate shock delivery (n=4, 1.3%). Twenty-four system revisions were performed as a result of major complications related to the EV ICD system or procedure. CONCLUSIONS: From implantation to study completion, the EV ICD Pivotal study demonstrated that a single integrated system with an extravascular lead placed in the substernal space maintains high ATP success, effective defibrillation, and a consistent safety profile. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04060680.
Comprehensive analysis of substernal lead removal: experience from EV ICD Pilot, Pivotal, and Continued Access Studies
Sagi, Venkata, Murgatroyd, Francis , Boersma, Lucas V.A. , Manlucu, Jaimie , Knight, Bradley P. , Leclercq, Christophe , Amin, Anish K. , Birgersdotter‐Green, Ulrika , Chan, Joseph Yat Sun , Roukoz, Henri , Denman, R. , Wiggenhorn, Christopher, Holmes, Thomas R, Lulic, Thomas, Friedman, Paul A. , Biffi, Mauro , Haqqani, Haris , Denman, Russell , Friedman, Paul A , Crozier, Ian , Knight, Bradley P , Boersma, Lucas , Amin, Anish, Biffi, Mauro , Holmes, Thomas R, Crozier, Ian

Europace | August 30, 2024 | Volume: 26 | Issue: 9 | Pages: No page available

10.1093/europace/euae225 Get It

Abstract Aims The extravascular implantable cardioverter-defibrillator (EV ICD) has been shown to be safe and effective for patients at risk of sudden cardiac death, but little is known about EV ICD lead removal in humans. This analysis aimed to characterize the EV ICD lead removal experience thus far. Methods and results This was a retrospective analysis of lead removals from the EV ICD Pilot, Pivotal, and Continued Access Studies. Patients with a successful EV ICD implant who underwent lead removal were included. The main objective was lead removal success. Ancillary objectives included characterizing technique used, procedure complications, and reimplantation status. An EV ICD system was successfully implanted in 347 patients across the 3 studies (25.9% female; 53.4 ± 13.3 years; left ventricular ejection fraction: 39.7 ± 15.9). Of these patients, 29 (8.4%) underwent lead removal with a mean lead dwell time of 12.6 ± 14.3 months (0.2–58.4). The main reason for lead removal was lead dislodgement (n = 9, 31.0%). Lead removal was successful in 27/29 (93.1%) cases [100% (19/19) success rate &lt;1 year and 80% (8/10) success rate &gt;1 year post-implant]. Simple traction was used in 22/26 (84.6%) and extraction tools in 4/26 (15.4%) successful cases where technique was known. No complications were reported for any of the removal procedures. All 11 EV ICD reimplant attempts were successful. Conclusion Complete removal of the EV ICD lead was successful in 93.1% of cases, and simple traction was sufficient in most instances. Based on these results, lead removal from the substernal space was safe and achievable up to 3 years post-implant.
Artificial intelligence enabled interpretation of ECG images to predict hematopoietic cell transplantation toxicity
Shaffer, Brian C. , Brown, Samantha , Chinapen, Stephanie , Mangold, Kathryn, Lahoud, Oscar , Schaffer, Wendy, Liu, Jennifer E. , Giralt, Sergio , Scordo, Michael , Papadopoulos, Esperanza B. , Landau, Heather , Friedman, Paul A. , Kosmidou, Ioanna , Giralt, Sergio , Papadopoulos, Esperanza , Landau, Heather , Perales, Miguel-Angel , Friedman, Paul A , Attia, Zachi I , Lahoud, Oscar B , López-Jiménez, Francisco , Devlin, Sean M. , Shah, Gunjan L. , Usmani, Saad Z. , Perales, Miguel‐Angel , Gersh, Bernard J. , Attia, Zachi I. , Noseworthy, Peter A.

Blood Advances | August 19, 2024 | Volume: 8 | Issue: 21 | Pages: 5603-5611

10.1182/bloodadvances.2024013636 Get It

Abstract Artificial intelligence (AI)–enabled interpretation of electrocardiogram (ECG) images (AI-ECGs) can identify patterns predictive of future adverse cardiac events. We hypothesized that such an approach would provide prognostic information for the risk of cardiac complications and mortality in patients undergoing hematopoietic cell transplantation (HCT). We retrospectively subjected ECGs obtained before HCT to an externally trained, deep-learning model designed to predict the risk of atrial fibrillation (AF). Included were 1377 patients (849 autologous [auto] HCT and 528 allogeneic [allo] HCT recipients). The median follow-up was 2.9 years. The 3-year cumulative incidence of AF was 9% (95% confidence interval [CI], 7-12) in patients who underwent auto HCT and 13% (10%-16%) in patients who underwent allo HCT. In the entire cohort, pre-HCT AI-ECG estimate of AF risk correlated highly with the development of clinical AF (hazard ratio [HR], 7.37; 95% CI, 3.53-15.4; P &lt; .001), inferior survival (HR, 2.4; 95% CI, 1.3-4.5; P = .004), and greater risk of nonrelapse mortality (NRM; HR, 95% CI, 3.36; 1.39-8.13; P = .007), without increased risk of relapse. Association with mortality was only noted in allo HCT recipients, where the risk of NRM was greater. The use of cyclophosphamide after transplantation resulted in greater 90-day incidence of AF (13% vs 5%; P = .01) compared to calcineurin inhibitor–based graft-versus-host disease prophylaxis, corresponding to temporal changes in AI-ECG AF prediction after HCT. In summary, AI-ECG can inform risk of posttransplant cardiac outcomes and survival in HCT patients and represents a novel strategy for personalized risk assessment.
Hypertrophic cardiomyopathy detection with artificial intelligence electrocardiography in international cohorts: an external validation study
Siontis, Konstantinos C. , Wieczorek, Mikolaj A. , Maanja, Maren , Hodge, David O. , Kim, Hyung‐Kwan , Lee, Heesun , Lim, Jaehyun , Ariga, Rina, Mahmod, Masliza , Ackerman, Michael J. , Friedman, Paul A. , Raman, Betty , Mahmod, Masliza , Watkins, Hugh , Neubauer, Stefan , Windecker, Stephan , Ackerman, Michael J , Friedman, Paul A , Kim, Hyung-Kwan , Lee, Hyun‐Jung , Park, Chan Soon , Watkins, Hugh , Windecker, Stephan , Siontis, George C.M. , Gersh, Bernard J. , Attia, Zachi I. , Noseworthy, Peter A.

European Heart Journal - Digital Health | April 13, 2024 | Volume: 5 | Issue: 4 | Pages: 416-426

10.1093/ehjdh/ztae029 Get It

Abstract Aims Recently, deep learning artificial intelligence (AI) models have been trained to detect cardiovascular conditions, including hypertrophic cardiomyopathy (HCM), from the 12-lead electrocardiogram (ECG). In this external validation study, we sought to assess the performance of an AI-ECG algorithm for detecting HCM in diverse international cohorts. Methods and results A convolutional neural network-based AI-ECG algorithm was developed previously in a single-centre North American HCM cohort (Mayo Clinic). This algorithm was applied to the raw 12-lead ECG data of patients with HCM and non-HCM controls from three external cohorts (Bern, Switzerland; Oxford, UK; and Seoul, South Korea). The algorithm’s ability to distinguish HCM vs. non-HCM status from the ECG alone was examined. A total of 773 patients with HCM and 3867 non-HCM controls were included across three sites in the merged external validation cohort. The HCM study sample comprised 54.6% East Asian, 43.2% White, and 2.2% Black patients. Median AI-ECG probabilities of HCM were 85% for patients with HCM and 0.3% for controls (P &lt; 0.001). Overall, the AI-ECG algorithm had an area under the receiver operating characteristic curve (AUC) of 0.922 [95% confidence interval (CI) 0.910–0.934], with diagnostic accuracy 86.9%, sensitivity 82.8%, and specificity 87.7% for HCM detection. In age- and sex-matched analysis (case–control ratio 1:2), the AUC was 0.921 (95% CI 0.909–0.934) with accuracy 88.5%, sensitivity 82.8%, and specificity 90.4%. Conclusion The AI-ECG algorithm determined HCM status from the 12-lead ECG with high accuracy in diverse international cohorts, providing evidence for external validity. The value of this algorithm in improving HCM detection in clinical practice and screening settings requires prospective evaluation.
Successful prediction of left bundle branch block‐induced cardiomyopathy and treatment effect by artificial intelligence‐enabled electrocardiogram
Carpenter, Caitlin, Friedman, Paul A. , Dhawan, Rahul, Friedman, Paul A , Dhawan, Rahul , Omer, Mohamed , Liu, Xiaoke

Pacing and Clinical Electrophysiology | April 7, 2024 | Volume: 47 | Issue: 6 | Pages: 776-779

10.1111/pace.14980 Get It

AbstractBackgroundLeft bundle branch block (LBBB) induced cardiomyopathy is an increasingly recognized disease entity. However, no clinical testing has been shown to be able to predict such an occurrence.Case reportA 70‐year‐old male with a prior history of LBBB with preserved ejection fraction (EF) and no other known cardiovascular conditions presented with presyncope, high‐grade AV block, and heart failure with reduced EF (36%). His coronary angiogram was negative for any obstructive disease. No other known etiologies for cardiomyopathy were identified. Artificial intelligence‐enabled ECGs performed 6 years prior to clinical presentation consistently predicted a high probability (up to 91%) of low EF. The patient successfully underwent left bundle branch area (LBBA) pacing with correction of the underlying LBBB. Subsequent AI ECGs showed a large drop in the probability of low EF immediately after LBBA pacing to 47% and then to 3% 2 months post procedure. His heart failure symptoms markedly improved and EF normalized to 54% at the same time.ConclusionsArtificial intelligence‐enabled ECGS may help identify patients who are at risk of developing LBBB‐induced cardiomyopathy and predict the response to LBBA pacing.
First‐in‐man report of transsubclavian venous implantation of the Aveir leadless cardiac pacing system
Ward, Robert C. , Amin, Hina , Noseworthy, Peter A. , Asirvatham, Samuel J. , Friedman, Paul A. , Mulpuru, Siva K. , Balanescu, Dinu V , Ward, Robert C , Noseworthy, Peter A , Asirvatham, Samuel J , Friedman, Paul A , Mulpuru, Siva K , Balanescu, Dinu Valentin

Journal of Cardiovascular Electrophysiology | March 11, 2024 | Volume: 35 | Issue: 5 | Pages: 1041-1045

10.1111/jce.16241 Get It

Abstract Introduction Transsubclavian venous implantation of the Aveir leadless cardiac pacemaker (LCP) has not been previously reported. Methods and Results Three cases of transsubclavian implantation of the Aveir LCP are reported. Two cases were postbilateral orthotopic lung transplant, without appropriate femoral or jugular access due to recent ECMO cannulation and jugular central venous catheters. In one case, there was strong patient preference for same‐day discharge. Stability testing confirmed adequate fixation and electrical testing confirmed stable parameters in all cases. All patients tolerated the procedure well without significant immediate complications. Conclusions We demonstrate the feasibility of transsubclavian implantation of the Aveir LCP.