Back to Authors

Watson, Robert E.

https://orcid.org/0000-0002-3271-5962

Mayo Clinic

Mayo Clinic

Citations 37

Image Artifact Management for Clinical Magnetic Resonance Imaging on a 7 T Scanner Using Single-Channel Radiofrequency Transmit Mode
Fagan, Andrew , Welker, Kirk M. , Amrami, Kimberly K. , Frick, Matthew A., Watson, Robert E. , Kollasch, Peter , Chebrolu, Venkata V. , Felmlee, Joel P. , Fagan, Andrew J

Investigative Radiology | September 10, 2019 | Volume: 54 | Issue: 12 | Pages: 781-791

10.1097/rli.0000000000000598 Get It

Objectives The aim of this work was to devise mitigation strategies for addressing a range of image artifacts on a clinical 7 T magnetic resonance imaging scanner using the regulatory-approved single-channel radiofrequency transmit mode and vendor-supplied radiofrequency coils to facilitate clinical scanning within reasonable scan times. Materials and Methods Optimized imaging sequence protocols were developed for routine musculoskeletal knee and neurological imaging. Sources of severe image nonuniformities were identified, and mitigation strategies were devised. A range of custom-made high permittivity dielectric pads were used to compensate for B1 + and B1 − inhomogeneities, and also for magnetic susceptibility-induced signal dropouts particularly in the basal regions of the temporal lobes and in the cerebellum. Results Significant improvements in image uniformity were obtained using dielectric pads in the knee and brain. A combination of small voxels, reduced field of view B0 shimming, and high in-plane parallel imaging factors helped to minimize signal loss in areas of high susceptibility-induced field distortions. The high inherent signal-to-noise ratio at 7 T allowed for high receiver bandwidths and thin slices to minimize chemical shift artifacts. Intermittent artifacts due to radiofrequency inversion pulse limitations (power, bandwidth) were minimized with dielectric pads. A patient with 2 implanted metallic cranial fixation devices located within the radiofrequency transmit field was successfully imaged, with minimal image geometric distortions. Conclusions Challenges relating to severe image artifacts at 7 T using single-channel radiofrequency transmit functionality in the knee and brain were overcome using the approaches described in this article. The resultant high diagnostic image quality paves the way for incorporation of this technology into the routine clinical workflow. Further developmental efforts are required to expand the range of applications to other anatomical areas, and to expand the evidence- and knowledge-base relating to the safety of scanning patients with implanted metallic devices.
Segmentation errors and intertest reliability in automated and manually traced hippocampal volumes
Brinkmann, Benjamin H. , Kenney‐Jung, Daniel , Mandrekar, Jay , Watson, Robert E. , Welker, Kirk M. , Witte, Robert J. , Guragain, Hari, Watson, Robert E , Brinkmann, Benjamin H , Guragain, Hari, Britton, Jeffrey W.

Annals of Clinical and Translational Neurology | September 6, 2019 | Volume: 6 | Issue: 9 | Pages: 1807-1814

10.1002/acn3.50885 Get It

AbstractObjectiveTo rigorously compare automated atlas‐based and manual tracing hippocampal segmentation for accuracy, repeatability, and clinical acceptability given a relevant range of imaging abnormalities in clinical epilepsy.MethodsForty‐nine patients with hippocampal asymmetry were identified from our institutional radiology database, including two patients with significant anatomic deformations. Manual hippocampal tracing was performed by experienced technologists on 3T MPRAGE images, measuring hippocampal volume up to the tectal plate, excluding the hippocampal tail. The same images were processed using NeuroQuant and FreeSurfer software. Ten subjects underwent repeated manual hippocampal tracings by two additional technologists blinded to previous results to evaluate consistency. Ten patients with two clinical MRI studies had volume measurements repeated using NeuroQuant and FreeSurfer.ResultsFreeSurfer raw volumes were significantly lower than NeuroQuant (P < 0.001, right and left), and hippocampal asymmetry estimates were lower for both automatic methods than manual tracing (P < 0.0001). Differences remained significant after scaling volumes to age, gender, and scanner matched normative percentiles. Volume reproducibility was fair (0.4–0.59) for manual tracing, and excellent (>0.75) for both automated methods. Asymmetry index reproducibility was excellent (>0.75) for manual tracing and FreeSurfer segmentation and fair (0.4–0.59) for NeuroQuant segmentation. Both automatic segmentation methods failed on the two cases with anatomic deformations. Segmentation errors were visually identified in 25 NeuroQuant and 27 FreeSurfer segmentations, and nine (18%) NeuroQuant and six (12%) FreeSurfer errors were judged clinically significant.InterpretationAutomated hippocampal volumes are more reproducible than hand‐traced hippocampal volumes. However, these methods fail in some cases, and significant segmentation errors can occur.
Gadolinium Administration in Undetected Pregnancy: Cause for Alarm?
Kallmes, David F. , Watson, Robert E.

Radiology | August 20, 2019 | Volume: 293 | Issue: 1 | Pages: 201-202

10.1148/radiol.2019191634 Get It

ACR guidance document on MR safe practices: Updates and critical information 2019
Greenberg, Todd D., Hoff, Michael N. , Gilk, Tobias , Och, Joseph, Rampulla, Tina L., Rogg, Jeffrey M. , Shellock, Frank G. , Watson, Robert E. , Weinreb, Jeffrey C. , Hernandez, Dina , Jackson, Edward F. , Kanal, Emanuel , McKinney, Alexander M. , Pedrosa, Iván , Reeder, Scott B.

Journal of Magnetic Resonance Imaging | July 29, 2019 | Volume: 51 | Issue: 2 | Pages: 331-338

10.1002/jmri.26880 Get It

The need for a guidance document on MR safe practices arose from a growing awareness of the MR environment's potential risks and adverse event reports involving patients, equipment, and personnel. Initially published in 2002, the American College of Radiology White Paper on MR Safety established de facto industry standards for safe and responsible practices in clinical and research MR environments. The most recent version addresses new sources of risk of adverse events, increases awareness of dynamic MR environments, and recommends that those responsible for MR medical director safety undergo annual MR safety training. With regular updates to these guidelines, the latest MR safety concerns can be accounted for to ensure a safer MR environment where dangers are minimized.Level of Evidence: 1Technical Efficacy Stage: 5J. Magn. Reson. Imaging 2020;51:331–338.
Patient-oriented education and visual-aid intervention are inadequate to identify patients with potential capsule retention: a prospective randomized study
Al‐Bawardy, Badr , Kamboj, Amrit K. , Desai, Shiv, Gorospe, Emmanuel C., Bruining, David H. , Gostout, Christopher J., Larson, Mark V., Nehra, Vandana, Leggett, Cadman L. , Szarka, Lawrence A., Watson, Robert E. , Rajan, Elizabeth , Gorospe, Emmanuel, Hansel, Stephanie L. , Leggett, Cadman L , Murray, Joseph A.

Scandinavian Journal of Gastroenterology | April 30, 2019 | Volume: 54 | Issue: 5 | Pages: 662-665

10.1080/00365521.2019.1608465 Get It

An unusual presentation of late-onset Alexander’s disease with slow orthostatic tremor and a novel GFAP variant
Stitt, Derek , Gavrilova, Ralitza H. , Watson, Robert E. , Hassan, Anhar , Stitt, Derek W, Watson, Robert

Neurocase | February 13, 2019 | Volume: 24 | Issue: 5-6 | Pages: 266-268

10.1080/13554794.2019.1580749 Get It

Augmenting MRI Safety Screening Processes: Reliable Identification of Cardiac Implantable Electronic Devices by a Ferromagnetic Detector System
Watson, Robert E. , Walsh, S., Felmlee, Joel P. , Friedman, Paul A. , Keene, Mark N., Walsh, Suson M

Journal of Magnetic Resonance Imaging | September 26, 2018 | Volume: 49 | Issue: 7 | Pages: No page available

10.1002/jmri.26277 Get It

Level of Evidence: 1Technical Efficacy Stage: 5 J. Magn. Reson. Imaging 2019;49:e297–e299.
Autoimmune epilepsy: findings on MRI and FDG-PET
Watson, Robert E. , Guerin, Julie, Carr, Carrie M. , Liebo, Greta B. , Kotsenas, Amy L. , Guérin, J.

The British Journal of Radiology | September 20, 2018 | Volume: 92 | Issue: 1093 | Pages: No page available

10.1259/bjr.20170869 Get It

Autoimmune epilepsy (AE) is becoming increasingly recognized as a potentially reversible cause of frequent or medically intractable seizures and cognitive deterioration. We describe various presentations of autoimmune encephalopathy which have specifically presented with seizure and describe reported imaging findings. This is organized as a review of the more common autoantibodies which can specifically precipitate seizure according to the intracellular or extracellular location of the targeted antigen. For each antibody, we illustrate their pathophysiology, characteristic clinical presentations with typical effective treatments and prognoses and imaging findings on MRI and PET/CT exams. Parenchymal involvement is variable with the limbic structures typically affected; however, non-limbic cortex, cerebellum, brainstem and basal ganglia can also be involved. In the acute setting, affected regions typically demonstrate T 2 hyperintensity with mild mass effect from edema and increased 18F-fludeoxyglucose uptake. Chronically involved parenchyma will often undergo atrophy and demonstrate decreased metabolism; mesial temporal sclerosis is often the end result when the limbic system is involved. Without treatment, long-term effects from AE range from ongoing cognitive dysfunction and refractory seizures to death. Familiarity with AE may prompt appropriate antibody screening, particularly in cases of refractory seizure disorders. Early investigation and proper management of AE cases may help to prevent parenchymal and neurologic deterioration in these patients.
P3698Correlation of lead length with procedural safety outcomes of magnetic resonance imaging in patients with legacy pacemakers and defibrillators
Padmanabhan, Deepak , Naksuk, Niyada , Deshmukh, Abhishek , Mulpuru, Siva K. , Felmlee, Joel P. , Dalzell, Connie, Olson, Nora E., Jondal, Mary Lou, Watson, Robert E. , Cha, Y, Friedman, Paul A. , Kella, Danesh , Isath, Ameesh , Kapa, Suraj , Asirvatham, Samuel J.

European Heart Journal | August 30, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy563.p3698 Get It

Laser ablation for mesial temporal epilepsy: a multi-site, single institutional series
Zimmerman, Richard S. , Brinkmann, Benjamin H. , Tatum, William O. , Crepeau, Amy Z. , Woodrum, David A. , Gorny, Krzysztof R. , Felmlee, Joel P. , Watson, Robert E. , Trenerry, Max R., Marsh, W. Richard , Wharen, Robert E. , Hoxworth, Joseph M. , Vibhute, Prasanna , Brinkmann, Benjamin H , Grewal, Sanjeet S. , Worrell, Gregory A. , Gupta, Vivek , Kaufmann, Timothy J. , Gompel, Jamie J. Van

Journal of Neurosurgery | July 6, 2018 | Volume: No volume available | Issue: No issue available | Pages: 1-8

10.3171/2018.2.jns171873 Get It

OBJECTIVE Although it is still early in its application, laser interstitial thermal therapy (LiTT) has increasingly been employed as a surgical option for patients with mesial temporal lobe epilepsy. This study aimed to describe mesial temporal lobe ablation volumes and seizure outcomes following LiTT across the Mayo Clinic’s 3 epilepsy surgery centers. METHODS This was a multi-site, single-institution, retrospective review of seizure outcomes and ablation volumes following LiTT for medically intractable mesial temporal lobe epilepsy between October 2011 and October 2015. Pre-ablation and post-ablation follow-up volumes of the hippocampus were measured using FreeSurfer, and the volume of ablated tissue was also measured on intraoperative MRI using a supervised spline-based edge detection algorithm. To determine seizure outcomes, results were compared between those patients who were seizure free and those who continued to experience seizures. RESULTS There were 23 patients who underwent mesial temporal LiTT within the study period. Fifteen patients (65%) had left-sided procedures. The median follow-up was 34 months (range 12–70 months). The mean ablation volume was 6888 mm 3 . Median hippocampal ablation was 65%, with a median amygdala ablation of 43%. At last follow-up, 11 (48%) of these patients were seizure free. There was no correlation between ablation volume and seizure freedom (p = 0.69). There was also no correlation between percent ablation of the amygdala (p = 0.28) or hippocampus (p = 0.82) and seizure outcomes. Twelve patients underwent formal testing with computational visual fields. Visual field changes were seen in 67% of patients who underwent testing. Comparing the 5 patients with clinically noticeable visual field deficits to the rest of the cohort showed no significant difference in ablation volume between those patients with visual field deficits and those without (p = 0.94). There were 11 patients with follow-up neuropsychological testing. Within this group, verbal learning retention was 76% in the patients with left-sided procedures and 89% in those with right-sided procedures. CONCLUSIONS In this study, there was no significant correlation between the ablation volume after LiTT and seizure outcomes. Visual field deficits were common in formally tested patients, much as in patients treated with open temporal lobectomy. Further studies are required to determine the role of amygdalohippocampal ablation.