Back to Authors

Lee, Kendall H.

https://orcid.org/0000-0001-9107-4221

Mayo Clinic

Mayo Clinic

Citations 81

Analysis of Carbon-Based Microelectrodes for Neurochemical Sensing
Manciu, Felicia , Barath, Abhijeet S. , Rusheen, Aaron E. , Kouzani, Abbas Z. , Hodges, Deidra , Guerrero, Jose, Tomshine, Jonathan R. , Lee, Kendall H. , Bennet, Kevin E. , Barath, Abhijeet, Rusheen, Aaron E , Kouzani, Abbas Z , Tomshine, Jonathan, Manciu, Felicia S , Oh, Yoonbae

Materials | September 30, 2019 | Volume: 12 | Issue: 19 | Pages: 3186

10.3390/ma12193186 Get It

The comprehensive microscopic, spectroscopic, and in vitro voltammetric analysis presented in this work, which builds on the well-studied properties of carbon-based materials, facilitates potential ways for improvement of carbon fiber microelectrodes (CFMs) for neuroscience applications. Investigations by both, scanning electron microscopy (SEM) and confocal Raman spectroscopy, confirm a higher degree of structural ordering for the fibers exposed to carbonization temperatures. An evident correlation is also identified between the extent of structural defects observed from SEM and Raman results with the CFM electrochemical performance for dopamine detection. To improve CFM physico-chemical surface stability and increase its mechanical resistance to the induced compressive stress during anticipated in vivo tissue penetration, successful coating of the carbon fiber with boron-doped diamond (BDD) is also performed and microspectroscopically analyzed here. The absence of spectral shifts of the diamond Raman vibrational signature verifies that the growth of an unstrained BDD thin film was achieved. Although more work needs to be done to identify optimal parameter values for improved BDD deposition, this study serves as a demonstration of foundational technology for the development of more sensitive electrochemical sensors, that may have been impractical previously for clinical applications, due to limitations in either safety or performance.
Electrophysiological Guidance of Epidural Electrode Array Implantation over the Human Lumbosacral Spinal Cord to Enable Motor Function after Chronic Paralysis
Calvert, Jonathan S. , Grahn, Peter J. , Strommen, Jeffrey A., Lavrov, Igor , Gill, Megan L., Linde, Margaux B. , Straaten, Meegan G. Van , Veith, Daniel D. , Lopez, Cesar , Sayenko, Dimitry G. , Gerasimenko, Yury , Edgerton, V. Reggie , Zhao, Kristin D. , Lee, Kendall H. , Lavrov, Igor A, Brown, Desmond A., Van Straaten, Meegan G, Lavrov, Igor , Trentadue, Taylor P , Beck, Lisa A., Brown, Desmond , Sayenko, Dimitry G

Journal of Neurotrauma | November 15, 2018 | Volume: 36 | Issue: 9 | Pages: 1451-1460

10.1089/neu.2018.5921 Get It

Epidural electrical stimulation (EES) of the spinal cord has been shown to restore function after spinal cord injury (SCI). Characterization of EES-evoked motor responses has provided a basic understanding of spinal sensorimotor network activity related to EES-enabled motor activity of the lower extremities. However, the use of EES-evoked motor responses to guide EES system implantation over the spinal cord and their relation to post-operative EES-enabled function in humans with chronic paralysis attributed to SCI has yet to be described. Herein, we describe the surgical and intraoperative electrophysiological approach used, followed by initial EES-enabled results observed in 2 human subjects with motor complete paralysis who were enrolled in a clinical trial investigating the use of EES to enable motor functions after SCI. The 16-contact electrode array was initially positioned under fluoroscopic guidance. Then, EES-evoked motor responses were recorded from select leg muscles and displayed in real time to determine electrode array proximity to spinal cord regions associated with motor activity of the lower extremities. Acceptable array positioning was determined based on achievement of selective proximal or distal leg muscle activity, as well as bilateral muscle activation. Motor response latencies were not significantly different between intraoperative recordings and post-operative recordings, indicating that array positioning remained stable. Additionally, EES enabled intentional control of step-like activity in both subjects within the first 5 days of testing. These results suggest that the use of EES-evoked motor responses may guide intraoperative positioning of epidural electrodes to target spinal cord circuitry to enable motor functions after SCI.
Fast Cyclic Square-Wave Voltammetry To Enhance Neurotransmitter Selectivity and Sensitivity
Park, Cheonho , Shin, Hojin , Kim, Jaekyung , Kang, Yumin , Sim, Jeongeun, Cho, Hyun U., Lee, Han Kyu , Jung, Sung Jun , Bennet, Kevin E. , Heien, Michael L. , Lee, Kendall H. , Kim, In Young , Jang, Dong Pyo , Heien, Michael L , Jang, Dong Pyo , Oh, Yoonbae , Blaha, Charles D.

Analytical Chemistry | October 25, 2018 | Volume: 90 | Issue: 22 | Pages: 13348-13355

10.1021/acs.analchem.8b02920 Get It

Abstract Although fast-scan cyclic voltammetry (FSCV) has been widely used for in vivo neurochemical detection, the sensitivity and selectivity of the technique can be further improved. In this study, we develop fast cyclic square-wave voltammetry (FCSWV) as a novel voltammetric technique that combines large-amplitude cyclic square-wave voltammetry (CSWV) with background subtraction. A large-amplitude, square-shaped potential was applied to induce cycling through multiple redox reactions within a square pulse to increase sensitivity and selectivity when combined with a two-dimensional voltammogram. As a result, FCSWV was significantly more sensitive than FSCV (n = 5 electrodes, two-way ANOVA, p = 0.0002). In addition, FCSWV could differentiate dopamine from other catecholamines (e.g., epinephrine and norepinephrine) and serotonin better than conventional FSCV. With the confirmation that FCSWV did not influence local neuronal activity, despite the large amplitude of the square waveform, it could monitor electrically induced phasic changes in dopamine release in rat striatum before and after injecting nomifensine, a dopamine reuptake inhibitor.
Stimulation of the subparafascicular thalamic nucleus modulates dopamine release in the inferior colliculus of rats
Batton, Aiyana D., Bieber, Allan J., Lee, Kendall H. , Boschen, Suelen L. , Bieber, Allan, Boschen, Suelen L , Blaha, Charles D.

Synapse | October 6, 2018 | Volume: 73 | Issue: 2 | Pages: No page available

10.1002/syn.22073 Get It

Abstract Although dopamine is commonly studied for its role in incentive motivation, cognition, and various neuropsychiatric disorders, evidence from Parkinson's disease (PD) patients that present auditory deficits suggest that dopamine is also involved in central auditory processing. It has been recently discovered that the subparafascicular thalamic nucleus (SPF) sends dopaminergic projections to the inferior colliculus (IC), an important convergence hub for the ascending and descending auditory pathways. In the present study, our aim was to provide neurochemical evidence that activation of SPF neurons evokes dopamine release in the IC of anesthetized rats using fast‐scan cyclic and paired pulse voltammetry in combination with carbon fiber microelectrodes. Electrical stimulation of the SPF (60 and 90 Hz) evoked dopamine release in the IC in a frequency‐dependent manner, with higher frequencies evoking greater amplitude dopamine responses. Optogenetic‐evoked dopamine responses were similar to the effects of electrical stimulation suggesting that electrical stimulation‐evoked dopamine release was not due to nonspecific activation of fibers of passage, but rather to activation of SPF cells projecting to the IC. Selective dopamine reuptake blockade enhanced the evoked dopamine response, while selective blockade of serotonin did not, confirming the selectivity of the neurochemical recordings to dopamine. Therefore, the SPF neuronal pathway functionally mediates dopamine release in the IC and thus may be involved in auditory processing deficits associated with PD.
A novel re-attachable stereotactic frame for MRI-guided neuronavigation and its validation in a large animal and human cadaver model
Edwards, Christine A. , Rusheen, Aaron E. , Paek, Seungleal, Lee, Kristen H, Dennis, Kendall D. , Bennet, Kevin E. , Kouzani, Abbas Z. , Lee, Kendall H. , Goerss, Stephan J., Paek, Seungleal B, Kouzani, Abbas Z , Oh, Yoonbae , Jacobs, Joshua J.

Journal of Neural Engineering | August 20, 2018 | Volume: 15 | Issue: 6 | Pages: 066003

10.1088/1741-2552/aadb49 Get It

Abstract Objective . Stereotactic frame systems are the gold-standard for stereotactic surgeries, such as implantation of deep brain stimulation (DBS) devices for treatment of medically resistant neurologic and psychiatric disorders. However, frame-based systems require that the patient is awake with a stereotactic frame affixed to their head for the duration of the surgical planning and implantation of the DBS electrodes. While frameless systems are increasingly available, a reusable re-attachable frame system provides unique benefits. As such, we created a novel reusable MRI-compatible stereotactic frame system that maintains clinical accuracy through the detachment and reattachment of its stereotactic devices used for MRI-guided neuronavigation. Approach . We designed a reusable arc-centered frame system that includes MRI-compatible anchoring skull screws for detachment and re-attachment of its stereotactic devices. We validated the stability and accuracy of our system through phantom, in vivo mock-human porcine DBS-model and human cadaver testing. Main results . Phantom testing achieved a root mean square error (RMSE) of 0.94 ± 0.23 mm between the ground truth and the frame-targeted coordinates; and achieved an RMSE of 1.11 ± 0.40 mm and 1.33 ± 0.38 mm between the ground truth and the CT- and MRI-targeted coordinates, respectively. In vivo and cadaver testing achieved a combined 3D Euclidean localization error of 1.85 ± 0.36 mm ( p < 0.03) between the pre-operative MRI-guided placement and the post-operative CT-guided confirmation of the DBS electrode. Significance . Our system demonstrated consistent clinical accuracy that is comparable to conventional frame and frameless stereotactic systems. Our frame system is the first to demonstrate accurate relocation of stereotactic frame devices during in vivo MRI-guided DBS surgical procedures. As such, this reusable and re-attachable MRI-compatible system is expected to enable more complex, chronic neuromodulation experiments, and lead to a clinically available re-attachable frame that is expected to decrease patient discomfort and costs of DBS surgery.
Multi-waveform fast-scan cyclic voltammetry mapping of adsorption/desorption kinetics of biogenic amines and their metabolites
Shin, Hojin , Park, Cheonho , Bennet, Kevin E. , Kim, In Young , Lee, Kendall H. , Jang, Dong Pyo , Kim, Do Hyoung , Oh, Yoonbae , Blaha, Charles D.

Analytical Methods | May 22, 2018 | Volume: 10 | Issue: 24 | Pages: 2834-2843

10.1039/c8ay00352a Get It

A novel multi-waveform FSCV (M-FSCV) developed for characterizing adsorption/desorption kinetics of neurotransmitters.
A baseline drift detrending technique for fast scan cyclic voltammetry
DeWaele, Mark, Park, Cheonho , Kang, Yu Min , Shin, Hojin , Bennet, Kevin E. , Lee, Kendall H. , Jang, Dong Pyo , Oh, Yoonbae , Blaha, Charles D. , Kim, In Young

The Analyst | September 27, 2017 | Volume: 142 | Issue: 22 | Pages: 4317-4321

10.1039/c7an01465a Get It

A simple, and yet robust, high pass filter is designed to remove non-linear background drift in fast scan cyclic voltammetry.
Instrumentation for electrochemical performance characterization of neural electrodes
Marsh, Michael P., Kruchowski, James, Hara, Seth A. , McIntosh, Malcom B., Forsman, Renae M., Reed, Terry L., Kimble, Christopher J., Lee, Kendall H. , Bennet, Kevin E. , Tomshine, Jonathan R. , Kruchowski, James N, Kimble, Christopher

Review of Scientific Instruments | August 1, 2017 | Volume: 88 | Issue: 8 | Pages: No page available

10.1063/1.4993796 Get It

In an effort to determine the chronic stability, sensitivity, and thus the potential viability of various neurochemical recording electrode designs and compositions, we have developed a custom device called the Voltammetry Instrument for Neurochemical Applications (VINA). Here, we describe the design of the VINA and initial testing of its functionality for prototype neurochemical sensing electrodes. The VINA consists of multiple electrode fixtures, a flowing electrolyte bath, associated reservoirs, peristaltic pump, voltage waveform generator, data acquisition hardware, and system software written in National Instrument’s LabVIEW. The operation of VINA was demonstrated on a set of boron-doped diamond neurochemical recording electrodes, which were subjected to an applied waveform for a period of eighteen days. Each electrode’s cyclic voltammograms (CVs) were recorded, and sensitivity calibration to dopamine (DA) was performed. Results showed an initial decline with subsequent stabilization in the CV current measured during the voltammetric sweep, corresponding closely with changes in electrode sensitivity to DA. The VINA has demonstrated itself as a useful tool for the characterization of electrode stability and chronic electrochemical performance.
Acute pressure changes in the brain are correlated with MR elastography stiffness measurements: initial feasibility in an in vivo large animal model
Arani, Arvin , Min, Hoon‐Ki , Fattahi, Nikoo , Wetjen, Nicholas M. , Trzasko, Joshua D. , Jack, Clifford R. , Lee, Kendall H. , Min, Hoon-Ki Paul , Manduca, Armando , Ehman, Richard L. , Huston, John , Jack, Clifford R , Arani, Arvin

Magnetic Resonance in Medicine | May 10, 2017 | Volume: 79 | Issue: 2 | Pages: 1043-1051

10.1002/mrm.26738 Get It

PurposeThe homeostasis of intracranial pressure (ICP) is of paramount importance for maintaining normal brain function. A noninvasive technique capable of making direct measurements of ICP currently does not exist. MR elastography (MRE) is capable of noninvasively measuring brain tissue stiffness in vivo, and may act as a surrogate to measure ICP. The objective of this study was to investigate the impact of changing ICP on brain stiffness using MRE in a swine model.MethodsBaseline MRE measurements were obtained, and then catheters were surgically placed into the left and right lateral ventricles of three animals. ICP was systematically increased over the range of 0 to 55 millimeters mercury (mmHg), and stiffness measurements were made using brain MRE at vibration frequencies of 60 hertz (Hz), 90 Hz, 120 Hz, and 150 Hz.ResultsA significant linear correlation between stiffness and ICP in the cross‐subject comparison was observed for all tested vibrational frequencies (P ≤ 0.01). The 120 Hz (0.030 ± 0.004 kilopascal (kPa)/mmHg, P < 0.0001) and 150 Hz (0.031 ± 0.008 kPa/mmHg, P = 0.01) vibrational frequencies had nearly identical slopes, which were approximately two‐ to three‐fold higher than the 90 Hz (0.017 ± 0.002 kPa/mmHg, P < 0.0001) and 60 Hz (0.009 ± 0.002 kPa/mmHg, P = 0.001) slopes, respectively.ConclusionIn this study, MRE demonstrated the potential for noninvasive measurement of changes in ICP. Magn Reson Med 79:1043–1051, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
Chapter 18 The Role of Astrocytes in Deep Brain Stimulation
Chang, Su-Youne , Lee, Kendall H.

Deep Brain Stimulation | December 2, 2016 | Volume: No volume available | Issue: No issue available | Pages: 339-356

10.1201/9781315364759-19 Get It