Back to Authors

Kim, In Young

https://orcid.org/0000-0002-4007-8465

Mayo Clinic

Hanyang University

Citations 4

Sensitive and Selective Measurement of Serotonin in Vivo Using Fast Cyclic Square-Wave Voltammetry
Shin, Hojin , Park, Cheonho , Kang, Yumin , Cho, Hyun U., Bennet, Kevin E. , Heien, Michael L. , Kim, In Young , Lee, Kendall H. , Jang, Dong Pyo , Heien, Michael L , Jang, Dong Pyo , Oh, Yoonbae , Blaha, Charles D.

Analytical Chemistry | December 2, 2019 | Volume: 92 | Issue: 1 | Pages: 774-781

10.1021/acs.analchem.9b03164 Get It

Fast Cyclic Square-Wave Voltammetry To Enhance Neurotransmitter Selectivity and Sensitivity
Park, Cheonho , Shin, Hojin , Kim, Jaekyung , Kang, Yumin , Sim, Jeongeun, Cho, Hyun U., Lee, Han Kyu , Jung, Sung Jun , Bennet, Kevin E. , Heien, Michael L. , Lee, Kendall H. , Kim, In Young , Jang, Dong Pyo , Heien, Michael L , Jang, Dong Pyo , Oh, Yoonbae , Blaha, Charles D.

Analytical Chemistry | October 25, 2018 | Volume: 90 | Issue: 22 | Pages: 13348-13355

10.1021/acs.analchem.8b02920 Get It

Abstract Although fast-scan cyclic voltammetry (FSCV) has been widely used for in vivo neurochemical detection, the sensitivity and selectivity of the technique can be further improved. In this study, we develop fast cyclic square-wave voltammetry (FCSWV) as a novel voltammetric technique that combines large-amplitude cyclic square-wave voltammetry (CSWV) with background subtraction. A large-amplitude, square-shaped potential was applied to induce cycling through multiple redox reactions within a square pulse to increase sensitivity and selectivity when combined with a two-dimensional voltammogram. As a result, FCSWV was significantly more sensitive than FSCV (n = 5 electrodes, two-way ANOVA, p = 0.0002). In addition, FCSWV could differentiate dopamine from other catecholamines (e.g., epinephrine and norepinephrine) and serotonin better than conventional FSCV. With the confirmation that FCSWV did not influence local neuronal activity, despite the large amplitude of the square waveform, it could monitor electrically induced phasic changes in dopamine release in rat striatum before and after injecting nomifensine, a dopamine reuptake inhibitor.
Multi-waveform fast-scan cyclic voltammetry mapping of adsorption/desorption kinetics of biogenic amines and their metabolites
Shin, Hojin , Park, Cheonho , Bennet, Kevin E. , Kim, In Young , Lee, Kendall H. , Jang, Dong Pyo , Kim, Do Hyoung , Oh, Yoonbae , Blaha, Charles D.

Analytical Methods | May 22, 2018 | Volume: 10 | Issue: 24 | Pages: 2834-2843

10.1039/c8ay00352a Get It

A novel multi-waveform FSCV (M-FSCV) developed for characterizing adsorption/desorption kinetics of neurotransmitters.
Monitoring In Vivo Changes in Tonic Extracellular Dopamine Level by Charge-Balancing Multiple Waveform Fast-Scan Cyclic Voltammetry
Park, Cheonho , Shin, Hojin , Kang, Yu Min , DeWaele, Mark, Lee, Jeyeon , Min, Hoon‐Ki , Bennet, Kevin E. , Kim, In Young , Lee, Kendall H. , Jang, Dong Pyo , Oh, Yoonbae , Kim, Do Hyoung , Min, Hoon-Ki Paul , Blaha, Charles D.

Analytical Chemistry | October 24, 2016 | Volume: 88 | Issue: 22 | Pages: 10962-10970

10.1021/acs.analchem.6b02605 Get It