BackgroundMR image intensity nonuniformity is often observed at 7T. Reference scans from the body coil used for uniformity correction at lower field strengths are typically not available at 7T.PurposeTo evaluate the efficacy of a novel algorithm, Uniform Combined Reconstruction (UNICORN), to correct receive coil‐induced nonuniformity in musculoskeletal 7T MRI without the use of a reference scan.Study TypeRetrospective image analysis study.SubjectsMRI data of 20 subjects was retrospectively processed offline.Field Strength/Sequence: Knees of 20 subjects were imaged at 7T with a single‐channel transmit, 28‐channel phased‐array receive knee coil. A turbo‐spin‐echo sequence was used to acquire 33 series of images.AssessmentThree fellowship‐trained musculoskeletal radiologists with cumulative experience of 42 years reviewed the images. The uniformity, contrast, signal‐to‐noise ratio (SNR), and overall image quality were evaluated for images with no postprocessing, images processed with N4 bias field correction algorithm, and the UNICORN algorithm.Statistical TestsIntraclass correlation coefficient (ICC) was used for measuring the interrater reliability. ICC and 95% confidence intervals (CIs) were calculated using the R statistical package employing a two‐way mixed‐effects model based on a mean rating (k = 3) for absolute agreement. The Wilcoxon signed‐rank test with continuity correction was used for analyzing the overall image quality scores.ResultsUNICORN was preferred among the three methods evaluated for uniformity in 97.9% of the pooled ratings, with excellent interrater agreement (ICC of 0.98, CI 0.97–0.99). UNICORN was also rated better than N4 for contrast and equivalent to N4 in SNR with ICCs of 0.80 (CI 0.72–0.86) and 0.67 (CI 0.54–0.77), respectively. The overall image quality scores for UNICORN were significantly higher than N4 (P < 6 × 10‐13), with good to excellent interrater agreement (ICC 0.90, CI 0.86–0.93).Data ConclusionWithout the use of a reference scan, UNICORN provides better image uniformity, contrast, and overall image quality at 7T compared with the N4 bias field‐correction algorithm.Level of Evidence: 4Technical Efficacy: Stage 1J. Magn. Reson. Imaging 2019;50:1534–1544.
Lightweight, compact, and high‐performance 3T MR system for imaging the brain and extremities
PurposeTo build and evaluate a small‐footprint, lightweight, high‐performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole‐body clinical 3T MRI scanners, while achieving substantial reductions in installation costs.MethodsA conduction‐cooled magnet was developed that uses less than 12 liters of liquid helium in a gas‐charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42‐cm inner‐diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet‐gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80‐mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1‐MVA gradient drivers.ResultsIn a comparison of anatomical imaging in 16 patients using T2‐weighted 3D fluid‐attenuated inversion recovery (FLAIR) between the compact 3T and whole‐body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80‐mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain.ConclusionsThe compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole‐body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
Magnetic Resonance Imaging Appearance of Schwannomas from Head to Toe: A Pictorial Review
Schwannomas are benign soft-tissue tumors that arise from peripheral nerve sheaths throughout the body and are commonly encountered in patients with neurofibromatosis Type 2. The vast majority of schwannomas are benign, with rare cases of malignant transformation reported. In this pictorial review, we discuss the magnetic resonance imaging (MRI) appearance of schwannomas by demonstrating a collection of tumors from different parts of the body that exhibit similar MRI characteristics. We review strategies to distinguish schwannomas from malignant soft-tissue tumors while exploring the anatomic and histologic origins of these tumors to discuss how this correlates with their imaging findings. Familiarity with the MRI appearance of schwannomas can help aid in the differential diagnosis of soft-tissue masses, especially in unexpected locations.
B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils
Background: Quantitative magnetic resonance (qMR) can be used to measure macromolecules in tissues and is a potential method of observing early cartilage changes in the development of posttraumatic osteoarthritis. Hypothesis/Purpose: We hypothesized that specific patient and surgical factors affecting cartilage matrix composition after anterior cruciate ligament (ACL) reconstruction (ACLR) can be detected using T1ρ and T2 relaxation times. Our purpose was to demonstrate this ability in a multicenter feasibility study. Study Design: Case series; Level of evidence, 4. Methods: A total of 54 patients who underwent ACLR underwent bilateral MRI at baseline before surgery and 6 months postoperatively. Operative findings were recorded. T1ρ and T2 relaxation times were calculated for 6 cartilage regions: the medial femur, lateral femur, medial tibia, lateral tibia, patella, and trochlea. A paired t test compared relaxation times at baseline and 6 months, univariate regression identified regions that influenced patient-reported outcome measures, and analysis of covariance was used to determine the surgical factors that resulted in elevated relaxation times at 6 months. Results: The injured knee had significantly prolonged T1ρ and T2 relaxation times in the tibiofemoral compartment at baseline and 6 months but had shorter values in the patellofemoral compartment compared with the uninjured knee. Prolonged T1ρ and T2 times at 6 months were noted for both the injured and uninjured knees. At 6 months, prolongation of T1ρ and T2 times in the tibial region was associated with lower patient-reported outcome measures. ACLR performed within 30 days of injury had significantly shorter T1ρ times in the tibial regions, and lateral meniscal tears treated with repair had significantly shorter T1ρ times than those treated with excision. Conclusion: Prolonged relaxation times in multiple regions demonstrate how the injury affects the entire joint after an ACL tear. Changes observed in the uninjured knee may be caused by increased loading during rehabilitation, especially in the patellofemoral articular cartilage and distal femur. Relaxation times in the tibial regions may be predictive of patient symptoms at 6 months. These same regions are affected by surgical timing as early as 30 days after injury, but this may partially be reflective of the severity of the preoperative injury and the choice of treatment of meniscal tears.
Safety Studies for Use of Adipose Tissue-Derived Mesenchymal Stromal/Stem Cells in a Rabbit Model for Osteoarthritis to Support a Phase I Clinical Trial
AbstractAdipose-derived mesenchymal stem cells (AMSCs) offer potential as a therapeutic option for clinical applications in musculoskeletal regenerative medicine because of their immunomodulatory functions and capacity for trilineage differentiation. In preparation for a phase I clinical trial using AMSCs to treat patients with osteoarthritis, we carried out preclinical studies to assess the safety of human AMSCs within the intra-articular joint space. Culture-expanded human AMSCs grown in human platelet-lysate were delivered via intra-articular injections into normal healthy rabbit knees and knees at risk for the development of osteoarthritis after bilateral medial anterior hemimeniscectomy. Treatment outcomes and safety were evaluated by assessing the general health, function, and behavior of the animals. Joint tissues were analyzed by x-ray, magnetic resonance imaging, and histopathology. Intra-articular AMSC therapy was well tolerated in this study. We did not observe adverse systemic reactions, nor did we find evidence of damage to intra-articular joint tissues. Thus, the data generated in this study show a favorable safety profile for AMSCs within the joint space in support of a phase I clinical trial evaluating the clinical utility of AMSCs to treat osteoarthritis.
Imaging Findings in Desmoplastic Fibroma of Bone: Distinctive T2 Characteristics