Back to Authors

Koff, Matthew F.

0000-0001-6969-0183

Mayo Clinic

Hospital for Special Surgery

Citations 2

Effects of Surgical Factors on Cartilage Can Be Detected Using Quantitative Magnetic Resonance Imaging After Anterior Cruciate Ligament Reconstruction
Amano, Keiko , Li, Alan , Pedoia, Valentina , Krych, Aaron J. , Li, Xiaojuan , Benjamin, C. , Goldring, Steven R., Hannafin, Jo A., Marx, Robert G. , Nawabi, Danyal H. , Shah, Parina, Warren, Russell F. , Amrami, Kimberly K. , Felmlee, Joel P. , Frick, Matthew A., Williams, Steven L. , Kretzchmar, Martin, Okazaki, Narihiro , Russell, Colin, Savic, Dragana , Schwaiger, Benedikt J. , Cheong, Maxwell, Hardin, John , Koff, Matthew F. , Link, Thomas M. , Potter, Hollis G. , Rodeo, Scott A. , Majumdar, Sharmila , Goldring, Mary B. , Otero, Miguel , Stuart, Michael James , Lansdown, Drew Anderson , Russell, Colin, Su, Favian , Wyatt, Cory R. , Krych, Aaron J

The American Journal of Sports Medicine | January 28, 2017 | Volume: 45 | Issue: 5 | Pages: 1075-1084

10.1177/0363546516677794 Get It

Background: Quantitative magnetic resonance (qMR) can be used to measure macromolecules in tissues and is a potential method of observing early cartilage changes in the development of posttraumatic osteoarthritis. Hypothesis/Purpose: We hypothesized that specific patient and surgical factors affecting cartilage matrix composition after anterior cruciate ligament (ACL) reconstruction (ACLR) can be detected using T1ρ and T2 relaxation times. Our purpose was to demonstrate this ability in a multicenter feasibility study. Study Design: Case series; Level of evidence, 4. Methods: A total of 54 patients who underwent ACLR underwent bilateral MRI at baseline before surgery and 6 months postoperatively. Operative findings were recorded. T1ρ and T2 relaxation times were calculated for 6 cartilage regions: the medial femur, lateral femur, medial tibia, lateral tibia, patella, and trochlea. A paired t test compared relaxation times at baseline and 6 months, univariate regression identified regions that influenced patient-reported outcome measures, and analysis of covariance was used to determine the surgical factors that resulted in elevated relaxation times at 6 months. Results: The injured knee had significantly prolonged T1ρ and T2 relaxation times in the tibiofemoral compartment at baseline and 6 months but had shorter values in the patellofemoral compartment compared with the uninjured knee. Prolonged T1ρ and T2 times at 6 months were noted for both the injured and uninjured knees. At 6 months, prolongation of T1ρ and T2 times in the tibial region was associated with lower patient-reported outcome measures. ACLR performed within 30 days of injury had significantly shorter T1ρ times in the tibial regions, and lateral meniscal tears treated with repair had significantly shorter T1ρ times than those treated with excision. Conclusion: Prolonged relaxation times in multiple regions demonstrate how the injury affects the entire joint after an ACL tear. Changes observed in the uninjured knee may be caused by increased loading during rehabilitation, especially in the patellofemoral articular cartilage and distal femur. Relaxation times in the tibial regions may be predictive of patient symptoms at 6 months. These same regions are affected by surgical timing as early as 30 days after injury, but this may partially be reflective of the severity of the preoperative injury and the choice of treatment of meniscal tears.
Short-term repeatability of joint space width measurements using a magnetic resonance imaging compatible knee positioning device
Stanley, Douglas, Weishaar, Paul , Amrami, Kimberly K. , Kaufman, Kenton R. , Koff, Matthew F. , Kaufman, Kenton R

Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | February 15, 2010 | Volume: 224 | Issue: 9 | Pages: 1061-1071

10.1243/09544119jeim735 Get It

The purpose of this study was to evaluate a magnetic resonance imaging (MRI) compatible knee positioning device to aid in minimizing intratechnologist and intertechnologist differences of minimum joint space width (JSW) measurements. Five subjects were scanned by two separate technologists, with and without an MRI-compatible positioning device. A semi-automated program calculated the minimum JSW of the tibiofemoral and patellofemoral joints. The scan-to-scan repeatability was evaluated from measurements between serial scans without subject repositioning, and the intratechnologist and intertechnologist repeatabilities were evaluated when the subject was removed from the magnet and repositioned by an individual technologist. The root mean square (RMS) error of the JSW measurements was also calculated. All measures of scan-to-scan repeatability and intratechnologist repeatability were unchanged with the MRI-compatible positioning device. The intertechnologist repeatability decreased from 0.70 to 0.42 mm, and the RMS error was significantly reduced ( P = 0.0006) from 0.26 to 0.15 mm for the tibiofemoral joint. The variability of patellofemoral JSW measurements increased when using the positioning device; however, the increases were not statistically significant. The intertechnologist repeatability increased from 1.55 to 1.79 mm, and the RMS error increased from 0.58 to 0.73 mm. The MRI-compatible positioning device was successful at reducing JSW measurement variability at the tibiofemoral joint. The increase in measurement variability at the patellofemoral joint may be due to local incongruities of the articular surfaces. An MRI-compatible positioning device may be beneficial for quantitative longitudinal studies evaluating knee joint health.