Citations

Mayo Clinic

Clear

162 citation(s) found for "Ehman, RL".

Immune checkpoint blockade (ICB) response evaluation with MRI/MR elastography (MRE) in surgical and nonsurgical patients with HCC.
Qayyum, Aliya , Avritscher, Rony , Aslam, Rizwan , Pagel, Mark D. , Sun, Jia , Abugabal, Yehia I., Hassan, Manal M. , Rashid, Asif , Lee, Sunyoung S. , Wolff, Robert A. , Ma, Jingfei , Amin, Hesham M. , Yao, James C. , Ehman, Richard L. , Duda, Dan G. , Kaseb, Ahmed O

Journal of Clinical Oncology | February 4, 2020 | Volume: 38 | Issue: 4_suppl | Pages: 480-480

10.1200/jco.2020.38.4_suppl.480 Get It

480 Background: Currently, there is a lack of imaging biomarkers of immunotherapy outcome in hepatocellular carcinoma (HCC). The study aim was to determine if HCC enhancement on MRI and stiffness change measured by magnetic resonance elastography (MRE) can predict immunotherapy response. Methods: This was a prospective, Institutional Review Board approved study of 38 patients with HCC treated with immune checkpoint blockade (ICB) therapy. All patients had liver MRI/MRE and HCC biopsy at baseline, and MRI/MRE with biopsy or resection after 6 weeks therapy. HCC stiffness (kPa) was measured on MRE elastograms (liver stiffness maps). HCC enhancement and change in stiffness were compared with treatment response to ICB in 1) non-surgical patients (pembrolizumab), and 2) surgical patients (nivolumab +/- ipilimumab). For non-surgical patients, treatment response was defined as overall survival >1 year. For surgical patients, treatment response was defined as <50% viable tumor at time of resection. Analysis was performed using descriptive statistics and Spearman correlation; p-value <0.05 was considered statistically significant. Results: Twenty-five patients were evaluable. Median age was 67 years (32, 78). Etiology of liver disease was NASH (n=8), HCV (n=8), HBV (n=2) and unknown (n=7). Treatment response occurred in 11/25 (44%) patients. Median HCC size and change in size were 4.7 cm (1.2, 14.0) and –0.32 cm, respectively. Median baseline HCC stiffness and change in stiffness were 5 kPa (2.2, 12.4) and –0.1 kPa (–2.2, 1.5), respectively. Median change in HCC size for responders and non-responders was –1.2 cm (–4.8, 0.4) and 0 cm (–1.5, 1.1), respectively (p = 0.02). Treatment response was associated with absence of portal venous phase capsular enhancement and increase in HCC stiffness, (p<0.001). Conclusions: Capsular enhancement and MRE stiffness change may be useful biomarkers of immune cell activated response to ICB therapy.
Image quality in abdominal CT using an iodine contrast reduction algorithm employing patient size and weight and low kV CT technique
Iyer, Veena R. , Ehman, Eric C. , Khandelwal, Ashish , Wells, Michael , Lee, Yong S. , Weber, Nikkole M. , Johnson, Matthew P. , Yu, Lifeng , Fletcher, Joel G. , Wells, Michael L, Fletcher, Joel G , Yu, Lifeng , McCollough, Cynthia H.

Acta Radiologica | January 27, 2020 | Volume: 61 | Issue: 9 | Pages: 1186-1195

10.1177/0284185119898655 | PMID 31986894 Get It

Background Low tube potential-high tube current computed tomography (CT) imaging allows reduction in iodine-based contrast dose and may extend the benefit of routine contrast-enhanced CT exams to patients at risk of nephrotoxicity. Purpose To determine the ability of an iodine contrast reduction algorithm to maintain diagnostic image quality for contrast-enhanced abdominal CT. Material and Methods CT exams with iodine contrast reduction were prescribed for patients at risk for renal dysfunction. The iodine contrast reduction algorithm combines weight-based contrast volume reduction with patient width-based low tube potential selection and bolus-tracking. Control exams with routine iodine dose were selected based on weight, width, and scan protocol. Three radiologists evaluated image quality and diagnostic confidence using a 4-point scale (<2 acceptable). Another radiologist assessed contrast reduction indications and measured portal vein and liver contrast-to-noise ratios. Results Forty-six contrast reduction algorithm and control exams were compared (mean creatinine 1.6 vs. 1.2 mg/dL, P ≤ 0.0001). Thirty-nine contrast reduction patients had an eGFR <60 mL/min/1.73m 2 and 15 had single or transplanted kidney. Mean iodine contrast dose was lower in the contrast reduction group (20.9 vs. 39.4 g/mL, P < 0.0001). Diagnostic confidence was rated as acceptable in 95% (131/138) of contrast reduction and 100% of control exams (1.18–1.28 vs. 1.02–1.13, respectively; P > 0.06). Liver attenuation and contrast-to-noise ratio (CNR) were similar ( P = 0.08), but portal vein attenuation and CNR were lower with contrast-reduction (mean 176 vs. 198 HU, P = 0.02; 13 vs. 16, P = 0.0002). Conclusion This size-based contrast reduction algorithm using low kV and bolus tracking reduced iodine contrast dose by 50%, while achieving acceptable image quality in 95% of exams.
Multiparametric Magnetic Resonance Elastography Improves the Detection of NASH Regression Following Bariatric Surgery
Allen, Alina M. , Shah, Vijay H. , Therneau, Terry M. , Venkatesh, Sudhakar K. , Mounajjed, Taofic, Larson, Joseph J. , Mara, Kristin C. , Kellogg, Todd A., Kendrick, Michael L. , McKenzie, Travis J. , Greiner, Suzanne , Li, Jiahui , Glaser, Kevin J. , Wells, Michael , Gunneson, Timothy J., Yin, Meng , Greiner, Suzanne M, Wells, Michael L, Venkatesh, Sudhakar K , Mara, Kristin C , Allen, Alina M , Yin, Meng , Li, Jiahui , Ehman, Richard L.

Hepatology Communications | November 5, 2019 | Volume: 4 | Issue: 2 | Pages: 185-192

10.1002/hep4.1446 | PMID 32025604 Get It

Disease monitoring in nonalcoholic steatohepatitis (NASH) is limited by absence of noninvasive biomarkers of disease regression or progression. We aimed to examine the role of multiparametric three‐dimensional magnetic resonance elastography (3D‐MRE) and magnetic resonance imaging proton density fat fraction (MRI‐PDFF) in the detection of NASH regression after interventions. This is a single‐center prospective clinical trial of 40 patients who underwent bariatric surgery. Imaging and liver biopsies were obtained at baseline and 1 year after surgery. The imaging protocol consisted of multifrequency 3D‐MRE to determine the shear stiffness at 60 Hz and damping ratio at 40 Hz, and MRI‐PDFF to measure the fat fraction. A logistic regression model including these three parameters was previously found to correlate with NASH. We assessed the model performance in the detection of NASH resolution after surgery by comparing the image‐predicted change in NAFLD activity score (delta NAS) to the histologic changes. A total of 38 patients (median age 43, 87% female, 30 of 38 with NAS ≥ 1, and 13 of 38 with NASH) had complete data at 1 year. The NAS decreased in all subjects with NAS ≥ 1 at index biopsy, and NASH resolved in all 13. There was a strong correlation between the predicted delta NAS by imaging and the delta NAS by histology (r = 0.73, P < 0.001). The strength of correlation between histology and the predicted delta NAS using single conventional parameters, such as the fat fraction by MRI‐PDFF or shear stiffness at 60 Hz by MRE, was r = 0.69 (P < 0.001) and r = 0.43 (P = 0.009), respectively. Conclusion: Multiparametric 3D‐MRE and MRI‐PDFF can detect histologic changes of NASH resolution after bariatric surgery. Studies in a nonbariatric setting are needed to confirm the performance as a composite noninvasive biomarker for longitudinal NASH monitoring.
re: Comparison of Technical Failure of MR Elastography for Measuring Liver Stiffness Between Gradient‐Recalled Echo and Spin‐Echo Echo‐Planar Imaging: A Systematic Review and Meta‐Analysis
Ehman, Richard L. , Ehman, Richard

Journal of Magnetic Resonance Imaging | October 6, 2019 | Volume: 51 | Issue: 4 | Pages: 1103-1104

10.1002/jmri.26937 | PMID 31587415 Get It

Normal range for MR elastography measured liver stiffness in children without liver disease
Sawh, Mary Catherine, Newton, Kimberly P. , Goyal, Nidhi , Angeles, Jorge E., Harlow, Kathryn E., Bross, Craig, Schlein, Alexandra , Hooker, Jonathan , Sy, Ethan , Glaser, Kevin J. , Yin, Meng , Schwimmer, Jeffrey B. , Schwimmer, Jeffrey B , Yin, Meng , Ehman, Richard L. , Sirlin, Claude B.

Journal of Magnetic Resonance Imaging | August 27, 2019 | Volume: 51 | Issue: 3 | Pages: 919-927

10.1002/jmri.26905 | PMID 31452280 Get It

BackgroundMagnetic resonance elastography (MRE) can determine the presence and stage of liver fibrosis. Data on normative MRE values, while reported in adults, are limited in children.PurposeTo determine the distribution of MRE‐measured liver stiffness in children without liver disease.Study TypeProspective, observational.PopulationEighty‐one healthy children (mean 12.6 ± 2.6 years, range 8–17 years).Field Strength/Sequence3.0T Signa HDxt, General Electric MR Scanner; 2D GRE MRE sequence.AssessmentHistory, examination, laboratory evaluation, and (MR) exams (proton density fat fraction, PDFF, and MRE) were performed. MR elastograms were analyzed manually at two reading centers and compared with each other for agreement and with published values in healthy adults and thresholds for fibrosis in adult and pediatric patients.Statistical TestsDescriptive statistics, Bland–Altman analysis, t‐test to compare hepatic stiffness values with reference standards.ResultsStiffness values obtained at both reading centers were similar, without significant bias (P = 0.362) and with excellent correlation (intraclass correlation coefficient [ICC] = 0.782). Mean hepatic stiffness value for the study population was 2.45 ± 0.35 kPa (95th percentile 3.19 kPa), which was significantly higher than reported values for healthy adult subjects (2.10 ± 0.23 kPa, P < 0.001). In all, 74–85% of subjects had stiffness measurements suggestive of no fibrosis.Data ConclusionMean liver stiffness measured with MRE in this cohort was significantly higher than that reported in healthy adults. Despite rigorous screening, some healthy children had stiffness measurements suggestive of liver fibrosis using current published thresholds. Although MRE has the potential to provide noninvasive assessment in patients with suspected hepatic disease, further refinement of this technology will help advance its use as a diagnostic tool for evidence of fibrosis in pediatric populations.Level of Evidence: 1Technical Efficacy: 5J. Magn. Reson. Imaging 2020;51:919–927.
Influence of Age on Global and Regional Brain Stiffness in Young and Middle‐Aged Adults
Takamura, Tomohiro , Sasaki, Yu , Takashi, Kakegawa, Glaser, Kevin J. , Motosugi, Utaroh , Sato, Kazuyuki , Ehman, Richard L. , Onishi, Hiroshi

Journal of Magnetic Resonance Imaging | August 2, 2019 | Volume: 51 | Issue: 3 | Pages: 727-733

10.1002/jmri.26881 | PMID 31373136 Get It

BackgroundAn understanding of potential age‐related changes in brain stiffness and its regional variation is important for further clinical application of MR elastography.PurposeTo investigate the effect of age on global and regional brain stiffness in young and middle‐aged adults.Study TypeProspective.SubjectsFifty subjects with normal brains and aged in their 20s, 30s, 40s, 50s, or 60s (five men, five women per decade).Field Strength/Sequence3.0T MRI and elastography with a vibration frequency of 60 Hz.AssessmentStiffness was measured in nine brain regions (cerebrum, temporal lobes, sensorimotor areas, frontotemporal composite region, deep gray matter and white matter (deep GM/WM), parietal lobes, occipital lobes, frontal lobes, and cerebellum) using an atlas‐based region‐of‐interest approach. The influence of age on regional brain stiffness was evaluated.Statistical TestsMultiple linear regression analysis, followed by Dunnett's multiple comparisons test, using subjects in their 20s as controls.ResultsFollowing adjustment for sex, multiple linear regression revealed a significant negative correlation between age and stiffness of the cerebrum (P < 0.0001), temporal lobes (P < 0.0001), sensorimotor areas (P < 0.0001), frontotemporal composite region (P < 0.0001), deep GM/WM (P = 0.0028), parietal lobes (P < 0.0001), occipital lobes (P = 0.0055), and frontal lobes (P < 0.0001). Dunnett's multiple comparison test showed that the stiffness of the sensorimotor areas, frontotemporal composite region, and frontal lobes was significantly decreased in subjects in their 40s (P < 0.0367), 50s (P < 0.0001), and 60s (P < 0.0001), while that of the cerebrum, temporal lobes, and parietal lobes was significantly decreased only in subjects in their 50s (P < 0.0012) and 60s (P < 0.0031) when compared with the controls.Data ConclusionThere is an age‐related decrease in brain stiffness that varies across the different regions.Level of Evidence: 1Technical Efficacy Stage: 2J. Magn. Reson. Imaging 2020;51:727–733.
Magnetic Resonance Elastography of Liver in Light Chain Amyloidosis
Venkatesh, Sudhakar K. , Hoodeshenas, Safa, Venkatesh, Sandeep H., Dispenzieri, Angela, Gertz, Morie A. , Torbenson, Michael S., Ehman, Richard L., Gertz, Morie A , Venkatesh, Sudhakar K , Hoodeshenas, Safa , Venkatesh, Sandeep Halagatti, Dispenzieri, Angela , Torbenson, Michael S., Ehman, Richard L.

Journal of Clinical Medicine | May 24, 2019 | Volume: 8 | Issue: 5 | Pages: 739

10.3390/jcm8050739 | PMID 31126105 Get It

In this paper, we present our preliminary findings regarding magnetic resonance elastography (MRE) on the livers of 10 patients with systemic amyloidosis. Mean liver stiffness measurements (LSM) and spleen stiffness measurements (SSM) were obtained. Magnetic resonance imaging (MRI) images were analyzed for the distribution pattern of amyloid deposition. Pearson correlation analysis was performed in order to study the correlation between LSM, SSM, liver span, liver volume, spleen span, spleen volume, serum alkaline phosphatase (ALP), N-terminal pro b-type natriuretic peptide (NT pro BNP), and the kappa and lambda free light chains. An increase in mean LSM was seen in all patients. Pearson correlation analysis showed a statistically significant correlation between LSM and liver volume (r = 0.78, p = 0.007) and kappa chain level (r = 0.65, p = 0.04). Interestingly, LSM did not correlate significantly with SSM (r = 0.45, p = 0.18), liver span (r = 0.57, p = 0.08), or serum ALP (r = 0.60, p = 0.07). However, LSM correlated significantly with serum ALP when corrected for liver volume (partial correlation, r = 0.71, p = 0.03) and NT pro BNP levels (partial correlation, r = 0.68, p = 0.04). MRI review revealed that amyloid deposition in the liver can be diffuse, lobar, or focal. MRE is useful for the evaluation of hepatic amyloidosis and shows increased stiffness in hepatic amyloidosis. MRE has the potential to be a non-invasive quantitative imaging marker for hepatic amyloidosis.
Soft tissue sarcoma stiffness and perfusion evaluation by MRE and DCE-MRI for radiation therapy response assessment: a technical feasibility study
Pepin, Kay , Grimm, Roger C., Howe, B. Matthew, Fritchie, Karen , Frick, Matthew A., Wenger, Doris E. , Okuno, Scott H. , McGee, Kiaran P. , James, Sarah, Laack, Nadia N., Herman, Michael , Pafundi, Deanna, Grimm, Roger, Kargar, Soudabeh , Frick, Matthew, Wenger, Doris, Ehman, Richard, McGee, Kiaran , Ehman, Richard L.

Biomedical Physics & Engineering Express | May 13, 2019 | Volume: 5 | Issue: 4 | Pages: 047003

10.1088/2057-1976/ab2175 | PMID 32110433 Get It

Abstract Soft tissue sarcomas are a rare and heterogeneous group of malignancies that present significant diagnostic and therapeutic challenges. Patient stratification based on tumor aggressiveness and early therapeutic response based on quantitative imaging may improve prediction of treatment response and the evaluation of new treatment strategies in clinical trials. The purpose of this pilot study was to determine the technical feasibility of magnetic resonance elastography (MRE) and dynamic contrast-enhanced (DCE) MRI for the evaluation of sarcoma stiffness and perfusion in 9 patients with histologically confirmed sarcoma. Additionally, we assessed the feasibility of utilizing MRE and DCE-MRI for the early evaluation of response to radiation therapy in 4 patients to determine the utility of further evaluation in a larger cohort study. Tumor size, stiffness, and perfusion parameters all decreased from baseline at the time of the pre-surgery or follow-up MRI, and results were compared to pathology or conventional imaging. MRE and DCE-MRI may be useful for the quantitative evaluation of tumor stiffness and perfusion, and therapy response assessment in soft tissue sarcomas.
The Role of Three‐Dimensional Magnetic Resonance Elastography in the Diagnosis of Nonalcoholic Steatohepatitis in Obese Patients Undergoing Bariatric Surgery
Shah, Vijay H. , Therneau, Terry M. , Venkatesh, Sudhakar K. , Mounajjed, Taofic, Larson, Joseph J. , Mara, Kristin C. , Schulte, Phillip J. , Kellogg, Todd A., Kendrick, Michael L. , McKenzie, Travis J. , Greiner, Suzanne , Li, Jiahui , Glaser, Kevin J. , Wells, Michael , Yin, Meng , Greiner, Suzanne M, Wells, Michael L, Venkatesh, Sudhakar K , Mara, Kristin C , Yin, Meng , Allen, Alina M. , Chen, Jun , Ehman, Richard L. , Li, Jiahui

Hepatology | December 24, 2018 | Volume: 71 | Issue: 2 | Pages: 510-521

10.1002/hep.30483 | PMID 30582669 Get It

The lack of reliable, noninvasive methods to diagnose early nonalcoholic steatohepatitis (NASH) is a major unmet need. We aimed to determine the diagnostic accuracy of three‐dimensional magnetic resonance elastography (3D‐MRE), with shear stiffness measured at 60 Hz, damping ratio at 40 Hz, and magnetic resonance imaging proton density fat fraction (MRI‐PDFF) in the detection of NASH in individuals undergoing bariatric surgery. Obese adults at risk for NASH were enrolled between 2015 and 2017 (prospective cohort, n = 88) and 2010 and 2013 (retrospective cohort, n = 87). The imaging protocol consisted of multifrequency 3D‐MRE (mf3D‐MRE) with shear waves delivered at different frequencies to explore parameters that best correlated with histologic NASH, and MRI‐PDFF to estimate steatosis. The prospective cohort was used to establish the optimal mf3D‐MRE technical parameters for NASH detection. The two cohorts were then combined to derive predictive models of NASH and disease activity by nonalcoholic fatty liver disease activity score (NAS) using the three imaging parameters that correlated with NASH. A total of 175 patients (median age 45, 81% women, and 81 [46%] with histologic NASH) were used for model derivation. From the complex shear modulus output generated by mf3D‐MRE, the damping ratio at 40 Hz and shear stiffness at 60 Hz best correlated with NASH. The fat fraction obtained from MRI‐PDFF correlated with steatosis ( P < 0.05 for all). These three parameters were fit into a logistic regression model that predicted NASH with cross‐validated area under the receiver operating characteristic curve (AUROC) = 0.73, sensitivity = 0.67, specificity = 0.80, positive predictive value = 0.73 and negative predictive value = 0.74, and disease activity by NAS with cross‐validated AUROC = 0.82. Conclusion: The mf3D‐MRE allows identification of imaging parameters that predict early NASH and disease activity. This imaging biomarker represents a promising alternative to liver biopsy for NASH diagnosis and monitoring. The results provide motivation for further studies in nonbariatric cohorts.
3D MR Elastography of Hepatocellular Carcinomas as a Potential Biomarker for Predicting Tumor Recurrence
Shan, Qungang , Yang, Hao , Kuang, Sichi , He, Bingjun , Zhang, Yao , Chen, Jingbiao , Zhang, Tianhui , Glaser, Kevin J. , Yin, Meng , Venkatesh, Sudhakar K. , Venkatesh, Sudhakar K , Yin, Meng , Wang, Jin , Liu, Yong , Zhu, Cairong , Chen, Jun , Ehman, Richard L.

Journal of Magnetic Resonance Imaging | September 8, 2018 | Volume: 49 | Issue: 3 | Pages: 719-730

10.1002/jmri.26250 | PMID 30260529 Get It

BackgroundPreoperative prediction of tumor recurrence is important in the management of patients with hepatocellular carcinoma (HCC).PurposeTo investigate whether tumor stiffness derived by magnetic resonance elastography (MRE) could predict early recurrence of HCC after hepatic resection.Study TypeRetrospective.PopulationIn all, 99 patients with pathologically confirmed HCCs after surgical resection.Field Strength/Sequence3.0T; preoperative MRE with 60‐Hz mechanical vibrations using an active acoustic driver.AssessmentRegions of interest (ROIs) were manually drawn in the tumors to measure mean tumor stiffness. Surgical specimens were reviewed for histological grade, capsule, vascular invasion, and surgical margins. The early recurrence of HCC was defined as that occurring within 2 years after resection.Statistical TestsCox proportional hazard models were used to evaluate risk factors associated with the time to early recurrence.ResultsHCCs with recurrence had higher tumor stiffness, higher rate of advanced T stage, vascular invasion, lower rate of capsule formation, larger tumor size, higher aspartate aminotransferase (AST), and hepatitis B virus (HBV)‐DNA level and aspartate aminotransferase / alanine aminotransferase ratio (P = 0.031, 0.007, 0.01, <0.001, 0.015, 0.034, 0.01, and 0.014, respectively) than HCCs without recurrence. Vascular invasion (hazard ratio [HR] = 2.922; 95% confidence interval [CI]: [1.079, 7.914], P = 0.035) and mean tumor stiffness (HR = 1.163; 95% CI: [1.055, 1.282], P = 0.002) were risk factors associated with early recurrence. Each 1‐kPa increase in tumor stiffness was associated with a 16.3% increase in the risk for tumor recurrence.Data ConclusionThe mean stiffness of HCCs may be a useful, noninvasive, quantitative biomarker for the prediction of early HCC recurrence after hepatic resection.Level of Evidence: 4Technical Efficacy: Stage 5J. Magn. Reson. Imaging 2019;49:719–730.