Citations

Mayo Clinic

Clear

1172 citation(s) found for "Ma, Cynthia".

Novel Treatment of Melanoma: Combined Parasite-Derived Peptide GK-1 and Anti-Programmed Death Ligand 1 Therapy
Vera-Aguilera, Jesús, Beltrán, D. Dualde , Villanueva-Ramos, Cynthia, Wachtel, Mitchell S. , Moreno-Aguilera, Eduardo, Vera-Aguilera, Carlos, Ventolini, Gary , Martı́nez–Zaguilán, Raul, Sennoune, Souad R. , Pérez‐Torres, Armando

Cancer Biotherapy and Radiopharmaceuticals | March 16, 2017 | Volume: 32 | Issue: 2 | Pages: 49-56

10.1089/cbr.2016.2123 | PMID 28301259 Get It

Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon counting detector CT system
Zhou, Wei , Montoya, Juan , Gutjahr, Ralf , Ferrero, Andrea , Halaweish, A., Kappler, S. , Halaweish, A., McCollough, Cynthia H. , Leng, Shuai , Zhou, Wei

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323Q

10.1117/12.2255736 | PMID 28392613 Get It

Detection of increased vasa vasorum in artery walls: improving CT number accuracy using image deconvolution
Rajendran, Kishore , Jorgensen, Steven M., Abdurakhimova, Dilbar, Ritman, Erik L., Leng, Shuai , McCollough, Cynthia H. , Rajendran, Kishore

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323O

10.1117/12.2255676 | PMID 28413240 Get It

Ultra-high spatial resolution multi-energy CT using photon counting detector technology
Gutjahr, Ralf , Ferrero, Andrea , Kappler, S. , Henning, André , Halaweish, A., Zhou, Wei , Montoya, Juan , Leng, Shuai , Halaweish, A., McCollough, Cynthia H. , Zhou, Wei

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101320Y

10.1117/12.2255589 | PMID 28392615 Get It

A virtual clinical trial using projection-based nodule insertion to determine radiologist reader performance in lung cancer screening CT
Yu, Lifeng , Hu, Qiyuan , Koo, Chi Wan , Takahashi, Edwin A. , Levin, David L. , Johnson, Tucker F. , Hora, Megan J., Dirks, Shane, Chen, Baiyu , McMillan, Kyle, Yu, Lifeng , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H. , Takahashi, Edwin A

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101321R

10.1117/12.2255593 | PMID 28392614 Get It

Practical implementation of channelized hotelling observers: effect of ROI size
Ferrero, Andrea , Favazza, Christopher , Yu, Lifeng , Favazza, Christopher P, Yu, Lifeng , Leng, Shuai , McCollough, Cynthia H.

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101320G

10.1117/12.2255530 | PMID 28943699 Get It

Dual energy CT kidney stone differentiation in photon counting computed tomography
Gutjahr, Ralf , Polster, Christoph, Henning, André , Kappler, S. , Sedlmair, Martin , Schmidt, Bernhard , Krauß, Bernhard , Flohr, Thomas , Leng, Shuai , McCollough, Cynthia H.

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 1013237

10.1117/12.2252021 | PMID 28943700 Get It

NeoPalAna: Neoadjuvant Palbociclib, a Cyclin-Dependent Kinase 4/6 Inhibitor, and Anastrozole for Clinical Stage 2 or 3 Estrogen Receptor–Positive Breast Cancer
Cynthia, X. , Northfelt, Donald W. , Forero, Andres , Anderson, Karen S. , Margenthaler, Julie A. , Aft, Rebecca , Hobday, Timothy J. , Moynihan, Timothy J. , Gillanders, William E. , Cyr, Amy, Eberlein, Timothy J. , Guo, Zhanfang , Lee, Michelle V. , Spies, Nicholas C. , Skidmore, Zachary L. , Griffith, Obi L. , Griffith, Malachi , Thomas, Shana , Bumb, Caroline, Bartlett, Cynthia Huang , Koehler, María , Al‐Kateb, Hussam , Sanati, Souzan , Hobday, Timothy, Moynihan, Timothy, Hieken, Tina, Gao, Feng , Luo, Jingqin , Goetz, Matthew P. , Hoog, Jeremy , Naughton, Michael J. , Ademuyiwa, Foluso O. , Suresh, Rama , Hieken, Tina J. , Krontiras, Helen , Vij, Kiran R , Ellis, Matthew J. , Griffith, Malachi , Griffith, Obi L

Clinical Cancer Research | March 7, 2017 | Volume: 23 | Issue: 15 | Pages: 4055-4065

10.1158/1078-0432.ccr-16-3206 | PMID 28270497 Get It

Abstract Purpose: Cyclin-dependent kinase (CDK) 4/6 drives cell proliferation in estrogen receptor–positive (ER+) breast cancer. This single-arm phase II neoadjuvant trial (NeoPalAna) assessed the antiproliferative activity of the CDK4/6 inhibitor palbociclib in primary breast cancer as a prelude to adjuvant studies. Experimental Design: Eligible patients with clinical stage II/III ER+/HER2− breast cancer received anastrozole 1 mg daily for 4 weeks (cycle 0; with goserelin if premenopausal), followed by adding palbociclib (125 mg daily on days 1–21) on cycle 1 day 1 (C1D1) for four 28-day cycles unless C1D15 Ki67 > 10%, in which case patients went off study due to inadequate response. Anastrozole was continued until surgery, which occurred 3 to 5 weeks after palbociclib exposure. Later patients received additional 10 to 12 days of palbociclib (Cycle 5) immediately before surgery. Serial biopsies at baseline, C1D1, C1D15, and surgery were analyzed for Ki67, gene expression, and mutation profiles. The primary endpoint was complete cell cycle arrest (CCCA: central Ki67 ≤ 2.7%). Results: Fifty patients enrolled. The CCCA rate was significantly higher after adding palbociclib to anastrozole (C1D15 87% vs. C1D1 26%, P < 0.001). Palbociclib enhanced cell-cycle control over anastrozole monotherapy regardless of luminal subtype (A vs. B) and PIK3CA status with activity observed across a broad range of clinicopathologic and mutation profiles. Ki67 recovery at surgery following palbociclib washout was suppressed by cycle 5 palbociclib. Resistance was associated with nonluminal subtypes and persistent E2F-target gene expression. Conclusions: Palbociclib is an active antiproliferative agent for early-stage breast cancer resistant to anastrozole; however, prolonged administration may be necessary to maintain its effect. Clin Cancer Res; 23(15); 4055–65. ©2017 AACR.
A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (
Wells, Michael , Froemming, Adam T. , Vrtiska, Terri J., Hartman, Robert P. , Holmes, David R. , Carter, Rickey E. , Bartley, Adam C. , Wells, Michael L, Kawashima, Akira , Kim, Bohyun , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Carter, Rickey E

Acta Radiologica | March 6, 2017 | Volume: 58 | Issue: 8 | Pages: 1012-1019

10.1177/0284185116682382 | PMID 28273736 Get It

Background Detection of small renal calculi has benefitted from recent advances in computed tomography (CT) scanner design. Information regarding observer performance when using state-of-the-art CT scanners for this application is needed. Purpose To assess observer performance and the impact of radiation dose for detection and size measurement of <4 mm renal stones using CT with integrated circuit detectors and iterative reconstruction. Material and Methods Twenty-nine <4 mm calcium oxalate stones were randomly placed in 20 porcine kidneys in an anthropomorphic phantom. Four radiologists used a workstation to record each calculus detection and size. JAFROC Figure of Merit (FOM), sensitivity, false positive detections, and calculus size were calculated. Results Mean calculus size was 2.2 ± 0.7 mm. The CTDI vol values corresponding to the automatic exposure control settings of 160, 80, 40, 25, and 10 Quality Reference mAs (QRM) were 15.2, 7.9, 4.2, 2.7, and 1.3 mGy, respectively. JAFROC FOM was ≥ 0.97 at ≥ 80 QRM, ≥ 0.89 at ≥ 25 QRM, and was inferior to routine dose (160 QRM) at 10 QRM (0.72, P < 0.05). Per-calculus sensitivity remained ≥ 85% for every reader at ≥ 25 QRM. Mean total false positive detections per reader were ≤ 3 at ≥ 80 QRM, but increased substantially for two readers ( ≥ 12) at ≤ 40 QRM. Measured calculus size significantly decreased at ≤ 25 QRM ( P ≤ 0.01). Conclusion Using low dose renal CT with iterative reconstruction and ≥ 25 QRM results in high sensitivity, but false positive detections increase for some readers at very low dose levels (≤ 40 QRM). At very low doses with iterative reconstruction, measured calculus size will artifactually decrease.
Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study
Brinjikji, Waleed , Michalak, Gregory J. , Kadirvel, Ramanathan , Gilvarry, Michael , Duffy, Sharon , Kallmes, David F. , Dai, Daying , McCollough, Cynthia, McCollough, Cynthia H. , Leng, Shuai

Interventional Neuroradiology | February 27, 2017 | Volume: 23 | Issue: 3 | Pages: 279-284

10.1177/1591019917694479 | PMID 28604189 Get It

Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.