Citations

Mayo Clinic

Clear

54 citation(s) found for "Rajendran, P".

The Multistage Antimalarial Compound Calxinin Perturbates P. falciparum Ca2+ Homeostasis by Targeting a Unique Ion Channel
Gupta, Yash , Sharma, Neha , Singh, Snigdha , Romero, Jesús G., Rajendran, Vinoth , Mogire, Reagan M. , Kashif, Mohammad , Jeske, Walter , Poonam, Poonam , Ogutu, Bernhards , Kanzok, Stefan M. , Akala, Hoseah M. , Legac, Jennifer, Rosenthal, Philip J., Rademacher, David J., Durvasula, Ravi , Singh, Agam Prasad , Rathi, Brijesh , Kempaiah, Prakasha , Poonam , Akala, Hoseah M , Singh, Agam P , Rathi, Brijesh , Kempaiah, Prakasha , Gupta, Yash , Beach, Jordan R. , Rosenthal, Philip Jon

Pharmaceutics | June 29, 2022 | Volume: 14 | Issue: 7 | Pages: 1371

10.3390/pharmaceutics14071371 | PMID 35890267 Get It

Malaria elimination urgently needs novel antimalarial therapies that transcend resistance, toxicity, and high costs. Our multicentric international collaborative team focuses on developing multistage antimalarials that exhibit novel mechanisms of action. Here, we describe the design, synthesis, and evaluation of a novel multistage antimalarial compound, ‘Calxinin’. A compound that consists of hydroxyethylamine (HEA) and trifluoromethyl-benzyl-piperazine. Calxinin exhibits potent inhibitory activity in the nanomolar range against the asexual blood stages of drug-sensitive (3D7), multidrug-resistant (Dd2), artemisinin-resistant (IPC4912), and fresh Kenyan field isolated Plasmodium falciparum strains. Calxinin treatment resulted in diminished maturation of parasite sexual precursor cells (gametocytes) accompanied by distorted parasite morphology. Further, in vitro liver-stage testing with a mouse model showed reduced parasite load at an IC50 of 79 nM. A single dose (10 mg/kg) of Calxinin resulted in a 30% reduction in parasitemia in mice infected with a chloroquine-resistant strain of the rodent parasite P. berghei. The ex vivo ookinete inhibitory concentration within mosquito gut IC50 was 150 nM. Cellular in vitro toxicity assays in the primary and immortalized human cell lines did not show cytotoxicity. A computational protein target identification pipeline identified a putative P. falciparum membrane protein (Pf3D7_1313500) involved in parasite calcium (Ca2+) homeostasis as a potential Calxinin target. This highly conserved protein is related to the family of transient receptor potential cation channels (TRP-ML). Target validation experiments showed that exposure of parasitized RBCs (pRBCs) to Calxinin induces a rapid release of intracellular Ca2+ from pRBCs; leaving de-calcinated parasites trapped in RBCs. Overall, we demonstrated that Calxinin is a promising antimalarial lead compound with a novel mechanism of action and with potential therapeutic, prophylactic, and transmission-blocking properties against parasites resistant to current antimalarials.
Estimating the Clinical Impact of Photon-Counting-Detector CT in Diagnosing Usual Interstitial Pneumonia
Inoue, Akitoshi , Johnson, Tucker F. , White, Darin , Cox, Christian W. , Hartman, Thomas E. , Thorne, Jamison E. , Shanblatt, Elisabeth R. , Johnson, Matthew P. , Carter, Rickey E. , Lee, Yong S. , Fletcher, Joel G , Carter, Rickey E , Inoue, Akitoshi , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Investigative Radiology | June 15, 2022 | Volume: 57 | Issue: 11 | Pages: 734-741

10.1097/rli.0000000000000888 | PMID 35703439 Get It

Objective The aim of this study was to evaluate the clinical impact of a higher spatial resolution, full field-of-view investigational photon-counting detector computed tomography (PCD-CT) on radiologist confidence in imaging findings and diagnosis of usual interstitial pneumonia (UIP) compared with conventional energy-integrating detector CT (EID-CT). Materials and Methods Patients suspected of interstitial lung disease were scanned on a PCD-CT system after informed consent and a clinically indicated EID-CT. In 2 sessions, 3 thoracic radiologists blinded to clinical history and scanner type evaluated CT images of the right and left lungs separately on EID- or PCD-CT, reviewing each lung once/session, rating confidence in imaging findings of reticulation, traction bronchiectasis, honeycombing, ground-glass opacities (GGOs), mosaic pattern, and lower lobe predominance (100-point scale: 0–33, likely absent; 34–66, indeterminate; 67–100, likely present). Radiologists also rated confidence for the probability of UIP (0–20, normal; 21–40, inconsistent with UIP; 41–60, indeterminate UIP; 61–81; probable UIP; 81–100, definite UIP) and graded image quality. Because a confidence scale of 50 represented completely equivocal findings, magnitude score (the absolute value of confidence scores from 50) was used for analysis (higher scores were more confident). Image noise was measured for each modality. The magnitude score was compared using linear mixed effects regression. The consistency of findings and diagnosis between 2 scanners were evaluated using McNemar test and weighted κ statistics, respectively. Results A total of 30 patients (mean age, 68.8 ± 11.0 years; M:F = 18:12) underwent conventional EID-CT (median CTDIvol, 7.88 mGy) and research PCD-CT (median CTDIvol, 6.49 mGy). The magnitude scores in PCD-CT were significantly higher than EID-CT for imaging findings of reticulation (40.7 vs 38.3; P = 0.023), GGO (34.4 vs 31.7; P = 0.019), and mosaic pattern (38.6 vs 35.9; P = 0.013), but not for other imaging findings (P ≥ 0.130) or confidence in UIP (34.1 vs 22.2; P < 0.059). Magnitude score of probability of UIP in PCD-CT was significantly higher than EID-CT in one reader (26.0 vs 21.5; P = 0.009). Photon-counting detector CT demonstrated a decreased number of indeterminate GGO (17 vs 26), an increased number of unlikely GGO (74 vs 50), and an increased number of likely reticulations (140 vs 130) relative to EID-CT. Interobserver agreements among 3 readers for imaging findings and probability of UIP were similar between PCD-CT and EID-CT (intraclass coefficient: 0.507–0.818 vs 0.601–0.848). Photon-counting detector CT had higher scores in overall image quality (4.84 ± 0.38) than those in EID-CT (4.02 ± 0.40; P < 0.001) despite increased image noise (mean 85.5 vs 36.1 HU). Conclusions Photon-counting detector CT provided better image quality and improved the reader confidence for presence or absence of imaging findings of reticulation, GGO, and mosaic pattern with idiosyncratic improvement in confidence in UIP presence.
Dynamic risk profiling of HCC recurrence after curative intent liver resection
Ivanics, Tommy , Perez, Carla , Claasen, Marco P. A. W. , Patel, Madhukar S. , Morgenshtern, Gabriela , Erdman, Lauren , Shwaartz, Chaya , Rajendran, Luckshi , O’Kane, Grainne M. , Murillo Perez, Carla Fiorella , Hansen, Bettina E. , Cleary, Sean P , Sapisochin, Gonzalo , Ivanics, Tommy , Cleary, Sean P. , Sapisochín, Gonzalo , Patel, Madhukar , O'Kane, Grainne M.

Hepatology | February 18, 2022 | Volume: 76 | Issue: 5 | Pages: 1291-1301

10.1002/hep.32411 | PMID 35178739 Get It

Abstract Background and Aims Following liver resection (LR) for HCC, the likelihood of survival is dynamic, in that multiple recurrences and/or metastases are possible, each having variable impacts on outcomes. We sought to evaluate the natural progression, pattern, and timing of various disease states after LR for HCC using multistate modeling and to create a practical calculator to provide prognostic information for patients and clinicians. Approach and Results Adult patients undergoing LR for HCC between January 2000 and December 2018 were retrospectively identified at a single center. Multistate analysis modeled post‐LR tumor progression by describing transitions between distinct disease states. In this model, the states included surgery, intrahepatic recurrence (first, second, third, fourth, fifth), distant metastasis with or without intrahepatic recurrence, and death. Of the 486 patients included, 169 (34.8%) remained recurrence‐free, 205 (42.2%) developed intrahepatic recurrence, 80 (16.5%) developed distant metastasis, and 32 (7%) died. For an average patient having undergone LR, there was a 33.1% chance of remaining disease‐free, a 31.0% chance of at least one intrahepatic recurrence, a 16.3% chance of distant metastasis, and a 19.8% chance of death within the first 60 months post‐LR. The transition probability from surgery to first intrahepatic recurrence, without a subsequent state transition, increased from 3% (3 months) to 17.4% (30 months) and 17.2% (60 months). Factors that could modify these probabilities included tumor size, satellite lesions, and microvascular invasion. The online multistate model calculator can be found on https://multistatehcc.shinyapps.io/home/. Conclusions In contrast to standard single time‐to‐event estimates, multistate modeling provides more realistic prognostication of outcomes after LR for HCC by taking into account many postoperative disease states and transitions between them. Our multistate modeling calculator can provide meaningful data to guide the management of patients undergoing postoperative surveillance and therapy.
Simultaneous dual‐contrast imaging using energy‐integrating detector multi‐energy CT: An in vivo feasibility study
Zhou, Zhongxing , Ren, Liqiang , Yu, Lifeng , Diehn, Felix E. , Rajendran, Kishore , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Medical Physics | January 12, 2022 | Volume: 49 | Issue: 3 | Pages: 1458-1467

10.1002/mp.15448 | PMID 35018658 Get It

AbstractPurposeTo demonstrate the feasibility of simultaneous dual‐contrast imaging in a large animal using a newly developed dual‐source energy‐integrating detector (EID)‐based multi‐energy computed tomography (MECT) system.MethodsTwo imaging tasks that may have potential clinical applications were investigated: head/neck (HN) CT angiography (CTA)/CT venography (CTV) with iodine and gadolinium, and small bowel imaging with iodine and bismuth in domestic swine. Dual‐source X‐ray beam configurations of 70 kV + Au120/Sn120 kV and 70 kV + Au140/Sn140 kV were used for the HN‐CTA/CTV and small bowel imaging studies, respectively. A test bolus scan was performed for each study. The regions of interest (ROIs) in the carotid artery and jugular vein for HN‐CTA/CTV imaging and abdominal aorta for small bowel imaging were used to determine the time‐attenuation curves, based on which the timing for contrast injection and the CT scan was determined. In the HN‐CTA/CTV study, an MECT scan was performed at the time point corresponding to the optimal arterial enhancement by iodine and the optimal venous enhancement by gadolinium. In the small bowel imaging study, an MECT scan was performed at the optimal time point to simultaneously capture the mesenteric arterial enhancement of iodine and the enteric enhancement of bismuth. Image‐based material decomposition was performed to decompose different materials for each study. To quantitatively characterize contrast material separation and misclassification, two ROIs on left common carotid artery and left internal jugular vein in HN‐CTA/CTV imaging and three ROIs on superior mesenteric artery, ileal lumen, and collapsed ileum (ileal wall) in small bowel imaging were placed to measure the mean concentration values and the standard deviations.ResultsIn the HN‐CTA/CTV study, common carotid arteries containing iodine and internal/external jugular veins containing gadolinium were clearly delineated from each other. Fine vessels such as cephalic veins and branches of external jugular veins were noticeable but clear visualization was hindered by image noise in gadolinium‐specific (CTV) images, as reviewed by a neuroradiologist. In the small bowel imaging study, the mesenteric arteries and collapsed bowel wall containing iodine and the small bowel loops containing bismuth were clearly distinctive from each other in the iodine‐ and bismuth‐specific images after material decomposition, as reviewed by an abdominal radiologist. Quantitative analyses showed that the misclassifications between the two contrast materials were less than 1.7 and 0.1 mg/ml for CTA/CTV and small bowel imaging studies, respectively.ConclusionsFeasibility of simultaneous CTA/CTV imaging in head and neck with iodine and gadolinium and simultaneous imaging of arterial and enteric phases of small bowel with iodine and bismuth, using a dual‐source EID‐MECT system, was demonstrated in a swine study. Compared to iodine and gadolinium in CTA/CTV, better delineation and classification of iodine and bismuth in small bowel imaging were achieved mainly due to wider separation between the corresponding two K‐edge energies.
Confirmation of Cause of Death Via Comprehensive Autopsy and Whole Exome Molecular Sequencing in People With Epilepsy and Sudden Unexpected Death
Chahal, C. Anwar A. , Tester, David J., Fayyaz, Ahmed U., Jaliparthy, Keerthi , Khan, Nadeem A., Lu, Dongmei , Khan, Mariha, Sahoo, Aradhana, Rajendran, Aiswarya, Knight, Jennifer A., Simpson, Michael A., Behr, Elijah R. , So, Elson L., Louis, Erik K. St. , Reichard, R. Ross, Edwards, William D., Ackerman, Michael J. , Simpson, Michael A. , St Louis, E K , Somers, Virend K. , Behr, Elijah Raphael , Chahal, Choudhary Anwar A , Tester, David J., Fayyaz, Ahmed U., Jaliparthy, Keerthi , Khan, Nadeem A., Lu, Dongmei , Khan, Mariha, Sahoo, Aradhana, Rajendran, Aiswarya, Knight, Jennifer A., Simpson, Michael A., So, Elson L., Reichard, R. Ross, Edwards, William D., Ackerman, Michael J

Journal of the American Heart Association | November 24, 2021 | Volume: 10 | Issue: 23 | Pages: No page available

10.1161/jaha.121.021170 | PMID 34816733 Get It

Background Sudden cardiac arrest is the leading mode of death in the United States. Epilepsy affects 1% of Americans; yet epidemiological data show a prevalence of 4% in cases of sudden cardiac arrest. Sudden unexpected death in epilepsy (SUDEP) may share features with sudden cardiac arrest. The objective of this study was to report autopsy and genomic findings in a large cohort of SUDEP cases. Methods and Results Mayo Clinic Sudden Death Registry containing cases (ages 0–90 years) of sudden unexpected and unexplained deaths 1960 to present was queried. Exome sequencing performed on decedent cases. From 13 687 cases of sudden death, 656 (4.8%) had a history of seizures, including 368 confirmed by electroencephalography, 96 classified as SUDEP, 58 as non‐SUDEP, and 214 as unknown (insufficient records). Mean age of death in SUDEP was 37 (±19.7) years; 56 (58.3%) were male; 65% of deaths occurred at night; 54% were found in bed; and 80.6% were prone. Autopsies were obtained in 83 cases; bystander coronary artery disease was frequently reported as cause of death; nonspecific fibrosis was seen in 32.6% of cases, in structurally normal hearts. There were 4 cases of Dravet syndrome with pathogenic variants in SCN1A gene. Using whole exome sequencing in 11 cases, 18 ultrarare nonsynonymous variants were identified in 6 cases including CACNB2, RYR2, CLNB, CACNA1H, and CLCN2 . Conclusions This study examined one of the largest single‐center US series of SUDEP cases. Several cases were reclassified as SUDEP, 15% had an ECG when alive, and 11 (11.4%) had blood for whole exome sequencing analysis. The most frequent antemortem genetic finding was pathogenic variants in SCN1A ; postmortem whole exome sequencing identified 18 ultrarare variants.
Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience
Rajendran, Kishore , Petersilka, Martin, Henning, André , Shanblatt, Elisabeth R. , Marsh, Jeffrey F., Thorne, Jamison E. , Schmidt, Bernhard , Flohr, Thomas , Marsh, Jeffrey, Thorne, Jamison, Fletcher, Joel, McCollough, Cynthia, Rajendran, Kishore , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Physics in Medicine & Biology | July 16, 2021 | Volume: 66 | Issue: 20 | Pages: 205019

10.1088/1361-6560/ac155e | PMID 34271558 Get It

Abstract We report a comprehensive evaluation of a full field-of-view (FOV) photon-counting detector (PCD) computed tomography (CT) system using phantoms, and qualitatively assess image quality in patient examples. A whole-body PCD-CT system with 50 cm FOV, 5.76 cm z-detector coverage and two acquisition modes (standard: 144 × 0.4 mm collimation and ultra-high resolution (UHR): 120 × 0.2 mm collimation) was used in this study. Phantoms were scanned to assess image uniformity, CT number accuracy, noise power spectrum, spatial resolution, material decomposition and virtual monoenergetic imaging (VMI) performance. Four patients were scanned on the PCD-CT system with matched or lower radiation dose than their prior clinical CT scans performed using energy-integrating detector (EID) CT, and the potential clinical impact of PCD-CT was qualitatively evaluated. Phantom results showed water CT numbers within ±5 HU, and image uniformity measured between peripheral and central regions-of-interests to be within ±5 HU. For the UHR mode using a dedicated sharp kernel, the cut-off spatial frequency was 40 line-pairs cm −1 , which corresponds to a 125 μ m limiting in-plane spatial resolution. The full-width-at-half-maximum for the section sensitivity profile was 0.33 mm for the smallest slice thickness (0.2 mm) using the UHR mode. Material decomposition in a multi-energy CT phantom showed accurate material classification, with a root-mean-squared-error of 0.3 mg cc −1 for iodine concentrations (2–15 mg cc −1 ) and 14.2 mg cc −1 for hydroxyapatite concentrations (200 and 400 mg cc −1 ). The average percent error for CT numbers corresponding to the iodine concentrations in VMI (40–70 keV) was 2.75%. Patient PCD-CT images demonstrated better delineation of anatomy for chest and temporal bone exams performed with the UHR mode, which allowed the use of very sharp kernels not possible with EID-CT. VMI and virtual non-contrast images generated from a patient head CT angiography exam using the standard acquisition mode demonstrated the multi-energy capability of the PCD-CT system.
Family History of Obstructive Sleep Apnea and Risk of Obesity
Rajendran, Aiswarya , Danyluk, Alexandria , Smith, Kevin L. , Boeve, Angelica, Bukartyk, Jan , Singh, Prachi R., Covassin, Naima , Smith, Kevin L., Somers, Virend K.

The FASEB Journal | June 21, 2021 | Volume: 33 | Issue: S1 | Pages: No page available

10.1096/fasebj.2019.33.1_supplement.lb520 Get It

Background Compelling evidence links obstructive sleep apnea (OSA), a prevalent sleep disorder, to heightened morbidity and mortality. Individuals with family history (FH) of OSA exhibit increased risk of developing this sleep disorder, suggesting that genetics, in addition to demographic and lifestyle factors, are likely implicated in the pathogenesis of OSA. However, it is unclear whether a positive FH of OSA predisposes to other unfavorable health outcomes. In this regard, data on its impact on vulnerability to obesity, both a precursor and a consequence of OSA, are lacking. Objective We sought to assess the association between FH of OSA and risk of obesity. Methods The study population consisted of 612 individuals (66% male, age 48.1±17.3 years) who took part in research studies performed in the Cardiovascular/Sleep Laboratory at Mayo Clinic and had complete family history data. FH of OSA and obesity were determined from questionnaires. Demographics and medical comorbidities including OSA diagnosis were obtained from self‐reports. Body mass index (BMI, kg/m 2 ) was calculated from height and weight measures and used to determine obesity status as follows: normal weight (BMI <25 kg/m 2 ), overweight (BMI 25–29.9 kg/m 2 ), and obese (BMI ≥30 kg/m 2 ). Measurements of waist circumference were obtained to determine central obesity (defined as waist circumference ≥88 cm in women and ≥102 cm in men). Results FH of OSA was reported by twelve percent of the sample (n=72). Individuals with FH of OSA were younger and more likely to be female than those without (age: 40.8±12.6 years vs 49.1±17.6 years, P<0.0001; sex: 48.6% vs 32.2%, P=0.008). Those with positive FH had higher BMI (31.5±6.8 kg/m 2 vs 29.2±7 kg/m 2 , P=0.009), were more frequently obese (59.7% vs 39.8%, P=0.007), and had higher prevalence of central obesity (67.7% vs 53.8%, P=0.036). Multivariable regression models showed the FH of OSA was associated with 3.2‐times greater risk of obesity (95% CI 1.7–5.9, P=0.0002) and with 2.3‐times greater risk of central obesity (95% CI 1.2–4.5, P=0.011) after correcting for age, sex, OSA diagnosis, and FH of obesity. Conclusion Family history of OSA is accompanied by an increased likelihood of obesity, especially central obesity, even if subjects with FH of OSA are much younger. This relationship is independent of conventional risk factors, including OSA diagnosis, suggesting that comorbid OSA in the offspring is unlikely to be implicated. Research addressing the potential pathophysiological mechanisms underlying our findings is warranted. Support or Funding Information Research support: VKS and PS are supported by NIH HL65176. NC is supported by American Heart Association grant 16SDG27250156, and Mayo Clinic CCaTS grant Marie Ingalls Cardiovascular Research Career Development Fund. This abstract is from the Experimental Biology 2019 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .
Deep-learning-based direct synthesis of low-energy virtual monoenergetic images with multi-energy CT
Gong, Hao , Marsh, Jeffrey F., DSouza, Karen N. , Huber, Nathan R. , D'Souza, Karen N , Rajendran, Kishore , McCollough, Cynthia H , Leng, Shuai , Rajendran, Kishore , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Journal of Medical Imaging | April 19, 2021 | Volume: 8 | Issue: 05 | Pages: No page available

10.1117/1.jmi.8.5.052104 | PMID 33889658 Get It

Diminished substrate‐mediated cardiac mitochondrial respiration and elevated autophagy in adult male offspring of gestational diabetic rats
Raji, Sasikala Rajendran, Nandini, Ravikumar Jayakumari, Ashok, Sivasailam , Anand, Chellappan Reghuvaran, Vivek, Velayudhan Pillai, Karunakaran, Jayakumar, Harikrishnan, Vijayakumar Sreelatha, Manjunatha, S , Gopala, Srinivas , Manjunatha, Shankarappa, Sreelatha, Harikrishnan Vijayakumar

IUBMB Life | January 23, 2021 | Volume: 73 | Issue: 4 | Pages: 676-689

10.1002/iub.2449 | PMID 33481330 Get It

AbstractHeart diseases are common in the offspring of diabetic mother (ODM). Defects in mitochondrial metabolism and autophagy may, in part, be responsible for the adverse structural and functional alterations in the heart. The principal objective of this study was to investigate cardiac mitochondrial respiration and autophagy in male and female offspring of diabetic pregnancy at two different developmental stages of life, weaning and adult. Male and female offspring of rats with streptozotocin‐induced gestational diabetes were used for the study and compared with offspring of control (non‐diabetic) mother (OCM) rats. High‐resolution respirometry was used to measure substrate‐mediated respiration in mitochondria isolated from ventricular tissues of ODM and OCM. Expression of proteins associated with autophagy and oxidative stress was examined by western blot analysis. Mitochondrial complex I and complex II respiration was significantly reduced in adult male ODM while it was unaltered or less affected in weaning male, adult and weaning female ODM. Elevated autophagy was observed in adult male but not in adult female ODM. Expression of oxidative stress markers was observed to be similar in all the groups. Altered cardiac mitochondrial respiration and autophagy were observed in adult male ODM compared to OCM, while the male and female offspring at weaning stage were less affected. The results of the study show that maternal hyperglycemia affects mitochondrial respiration and autophagy in the ODM heart, which may potentially be responsible for the cardiovascular complications observed in adult life.