Citations

Mayo Clinic

Showing 10 of 108572 citations.

Wake and non-rapid eye movement sleep dysfunction is associated with colonic neuropathology in Parkinson’s disease
Sadoc, Mathilde, Clairembault, Thomas, Coron, Emmanuel , Berthomier, Christian , Dily, Séverine Le, Vavasseur, Fabienne , Pavageau, Albane, Louis, Erik K. St. , Péréon, Yann , Neunlist, Michel , St Louis, E K , LeClair-Visonneau, Laurene , Derkinderen, Pascal , Leclair‐Visonneau, Laurène

SLEEP | December 20, 2023 | Volume: 47 | Issue: 3 | Pages: No page available

10.1093/sleep/zsad310 | PMID 38156524 Get It

Abstract Study Objectives The body-first Parkinson’s disease (PD) hypothesis suggests initial gut Lewy body pathology initially propagates to the pons before reaching the substantia nigra, and subsequently progresses to the diencephalic and cortical levels, a disease course presumed to likely occur in PD with rapid eye movement sleep behavior disorder (RBD). We aimed to explore the potential association between colonic phosphorylated alpha-synuclein histopathology (PASH) and diencephalic or cortical dysfunction evidenced by non-rapid eye movement (NREM) sleep and wakefulness polysomnographic markers. Methods In a study involving 43 patients with PD who underwent clinical examination, rectosigmoidoscopy, and polysomnography, we detected PASH on colonic biopsies using whole-mount immunostaining. We performed a visual semi-quantitative analysis of NREM sleep and wake electroencephalography (EEG), confirmed it with automated quantification of spindle and slow wave features of NREM sleep, and the wake dominant frequency, and then determined probable Arizona PD stage classifications based on sleep and wake EEG features. Results The visual analysis aligned with the automated quantified spindle characteristics and the wake dominant frequency. Altered NREM sleep and wake parameters correlated with markers of PD severity, colonic PASH, and RBD diagnosis. Colonic PASH frequency also increased in parallel to probable Arizona PD stage classifications. Conclusions Colonic PASH is strongly associated with widespread brain sleep and wake dysfunction, suggesting an extensive diffusion of the pathologic process in PD. Visual and automated analyses of polysomnography signals provide useful markers to gauge covert brain dysfunction in PD. Clinical Trial Name: SYNAPark, URL: https://clinicaltrials.gov/study/NCT01748409, registration: NCT01748409
Performance of ChatGPT-4 and Bard Chatbots in Responding to Common Patient Questions on Prostate Cancer 177Lu-PSMA-617 Therapy
Bilgin, Gokce Belge , Bilgin, Cem , Orme, Jacob J. , Burkett, Brian J. , Packard, Annie T. , Johnson, Geoffrey B. , Sartor, Oliver A., Johnson, Geoffrey B , Burkett, Brian , Belge Bilgin, Gokce , Childs, Daniel S. , Johnson, Derek R. , Thorpe, Matthew , Riaz, Irbaz Bin , Hálfdánarson, Þorvarður R. , Kendi, A. Tuba

No container title available | December 20, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-3728387/v1 Get It

Abstract Background: Many patients use artificial intelligence (AI) chatbots as a rapid source of health information. This raises important questions about the reliability and effectiveness of AI chatbots in delivering accurate and understandable information. Purpose: To evaluate and compare the accuracy, conciseness, and readability of responses from OpenAI ChatGPT-4 and Google Bard to patient inquiries concerning the novel 177Lu-PSMA-617 therapy for prostate cancer. Materials and Methods: Two experts listed the 12 most commonly asked questions by patients on 177Lu-PSMA-617 therapy. These twelve questions were prompted to OpenAI ChatGPT-4 and Google Bard. AI-generated responses were distributed using an online survey platform (Qualtrics) and blindly rated by eight experts. The performances of the AI chatbots were evaluated and compared across three domains: accuracy, conciseness, and readability. Additionally, potential safety concerns associated with AI-generated answers were also examined. The Mann-Whitney U and chi-square tests were utilized to compare the performances of AI chatbots. Results: Eight experts participated in the survey, evaluating 12 AI-generated responses across the three domains of accuracy, conciseness, and readability, resulting in 96 assessments (12 responses x 8 experts) for each domain per chatbot. ChatGPT-4 provided more accurate answers than Bard (2.95 ± 0.671 vs 2.73 ± 0.732, p=0.027). Bard's responses had better readability than ChatGPT-4 (2.79 ± 0.408 vs 2.94 ± 0.243, p=0.003). Both ChatGPT-4 and Bard achieved comparable conciseness scores (3.14 ± 0.659 vs 3.11 ± 0.679, p=0.798). Experts categorized the AI-generated responses as incorrect or partially correct at a rate of 16.6% for ChatGPT-4 and 29.1% for Bard. Bard's answers contained significantly more misleading information than those of ChatGPT-4 (p = 0.039). Conclusion: AI chatbots have gained significant attention, and their performance is continuously improving. Nonetheless, these technologies still need further improvements to be considered reliable and credible sources for patients seeking medical information on 177Lu-PSMA-617 therapy.
Integrative Pharmacology in the Treatment of Substance Use Disorders
Donlon, Jack, Varghese, Sajoy P. , Florentin, Ori David, Frost, Emma D., Banks, J., Vadlapatla, Niyathi, Kam, Olivia , Rahman, Shafiqur , Koola, Maju Mathew , Abulseoud, Osama A. , Kumari, Pooja, Bai, Michael Y. , Banks, John, Shad, Mujeeb , Stone, Trevor W.

Journal of Dual Diagnosis | December 20, 2023 | Volume: 20 | Issue: 2 | Pages: 132-177

10.1080/15504263.2023.2293854 | PMID 38117676 Get It

Infrapopliteal Segments on Lower Extremity CTA: Prospective Intraindividual Comparison of Energy-Integrating Detector CT and Photon-Counting Detector CT
Yalon, Mariana , Thorne, Jamison E. , Lee, Yong S. , Johnson, Matthew P. , Esquivel, Andrea , Rajiah, Prabhakar Shantha, Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Rajiah, Prabhakar

American Journal of Roentgenology | December 20, 2023 | Volume: 222 | Issue: 3 | Pages: No page available

10.2214/ajr.23.29778 | PMID 37991334 Get It

Incidence of injury and illness among paediatric Team USA athletes competing in the 2020 Tokyo and 2022 Beijing Olympic and Paralympic Games
Post, Eric G. , Anderson, Travis , Shilt, Jeffrey S. , Dugan, Eric L. , Clark, Stephanie C., Larson, Emily G., Noble-Taylor, Kayle E, Donaldson, Amber , Finnoff, Jonathan T. , Donaldson, Amber T , Finnoff, Jonathan T , Adams, William M , Anderson, Travis , Noble-Taylor, Kayle E., Robinson, David M. , Adams, William M.

BMJ Open Sport & Exercise Medicine | December 20, 2023 | Volume: 9 | Issue: 4 | Pages: e001730

10.1136/bmjsem-2023-001730 | PMID 38143720 Get It

Objective To describe the incidence of injuries and illnesses among paediatric Team USA athletes competing in the Tokyo 2020 Olympic and Paralympic Games, and the 2022 Beijing Olympic and Paralympic Games. Methods An electronic medical record system documented all injuries and illnesses that occurred while competing in the four Games periods. Incidence (IR) with 95% CI per 1000 athlete days were calculated for both injuries and illnesses. Incidence rate ratios (IRR) were calculated to compare injury and illness rates based on age (paediatric vs non-paediatric) sex, Games period and sport type. Results Two hundred paediatric athletes (age range, 15–21 years) competed across the four Games periods, representing 16.1% of all Team USA athletes. The overall injury IR (95% CI) was 13.4 (9.8 to 18.1), and the overall illness IR was 5.5 (3.3 to 8.7). There were no differences in incidence between paediatric and non-paediatric athletes for either injury (IRR (95% CI): 0.9 (0.6 to 1.2)) or illness (IRR (95% CI): 0.9 (0.5 to 1.5)). Female paediatric athletes were more likely to sustain an injury compared with male paediatric athletes (IRR (95% CI): 2.4 (1.1 to 5.3)). The most common mechanism of injury was gradual onset (IR, 4.3 (2.3 to 7.2)), and injuries most commonly occurred during practices (IR, 7.0 (4.5 to 10.5)). Conclusion Paediatric athletes account for a substantial proportion of Team USA athletes. It is essential that paediatric sports medicine experts are included in the medical team given that paediatric Team USA athletes are just as likely as their adult teammates to sustain an injury or illness.
A Sequential Follower Refinement Algorithm for Robust Surgery Scheduling
Bansal, Ankit , Berg, Bjorn P. , Huang, Yu-Li , Richard, Jean‐Philippe P.

INFORMS Journal on Computing | December 20, 2023 | Volume: 36 | Issue: 3 | Pages: 918-937

10.1287/ijoc.2022.0191 Get It

An algorithm for the two-stage robust optimization surgery-to-operating room allocation problem is presented. The second-stage problem is an integer linear program whose convex hull is approximated using three types of specialized valid inequalities and Chvátal-Gomory cuts. The resulting linear relaxation of the second-stage problem is then dualized and integrated into the first-stage problem. The resulting mixed integer linear program, which is an approximation of the original problem, is then solved using a commercial solver. If the solution of this model is not optimal for the second-stage problem, valid inequalities for the second-stage problem are generated, yielding a type of column-generation based approach that we refer to as the sequential follower refinement (SFR) algorithm. Data from an academic medical center are used to compare the computational performance of SFR with the constraint and column generation (C&CG) algorithm, which is the only exact approach that has been specifically applied for this problem in the literature. An extensive numerical study of SFR and its computational characteristics is presented that shows that SFR yields better-quality solutions compared with C&CG, even as the termination criterion of SFR is met much sooner, especially for problems involving higher number of surgeries.History: Accepted by Paul Brooks, Area Editor for Applications in Biology, Medicine, & Healthcare.Supplemental Material: The software that supports the findings of this study is available within the paper and its Supplemental Information ( https://pubsonline.informs.org/doi/suppl/10.1287/ijoc.2022.0191 ) as well as from the IJOC GitHub software repository ( https://github.com/INFORMSJoC/2022.0191 ). The complete IJOC Software and Data Repository is available at https://informsjoc.github.io/ .
The effect of frequency (64–498 MHz) on specific absorption rate adjacent to metallic orthopedic screws in MRI: A numerical simulation study
Jacobs, Paul , Fagan, Andrew

Medical Physics | December 20, 2023 | Volume: 51 | Issue: 2 | Pages: 1074-1082

10.1002/mp.16902 | PMID 38116822 Get It

AbstractBackgroundThe imaging of patients with implanted electrically‐conductive devices via magnetic resonance imaging at ultra‐high fields is hampered by uncertainties relating to the potential for inducing tissue heating adjacent to the implant due to coupling of energy from the incident electromagnetic field into the implant. Existing data in the peer‐reviewed literature of comparisons across field strengths of tissue heating and its surrogate, the specific absorption rate (SAR), is scarce and contradictory, leading to further doubts pertaining to the safety of imaging patients with such devices.PurposeThe radiofrequency‐induced SAR adjacent to orthopedic screws of varying length and at frequencies of 64 to 498 MHz was investigated via full‐wave electromagnetic simulations, to provide an accurate comparison of SAR across MRI field strengths.MethodsDipole antennas were used for RF transmission to achieve a uniform electric field tangential to the screws located 120 mm above the antenna midpoints, embedded in a bone‐mimicking material. The input power to the antennas was constrained to achieve the following targets without the screw present: (i) E = 100 V/m, (ii) B1+ = 2 μT, and (iii) global‐average‐SAR = 3.2 W/kg. Simulations were performed with a spatial resolution of 0.2 mm in the volume surrounding the screws, resulting in 76–137 MCells, noting the maximum 1 g‐averaged SAR value in each case. Simulations were repeated at 128 and 297 MHz for screws embedded in muscle tissue.ResultsThe peak SAR, occurring at the resonant screw length, substantially increased as the frequency decreased when the input power to the dipole antenna was constrained to achieve constant electric field in background tissue at the screws’ locations. A similar pattern was observed when constraining input power to achieve constant B1+ and global‐average‐SAR. The dielectric properties of the tissue in which the screws were embedded dominated the SAR comparisons between 297 and 128 MHz.ConclusionsThe study design allowed for a direct comparison to be performed of SAR across frequencies and implant lengths without the confounding effect of variable incident electric field. Lower frequencies produced substantially larger SAR values for implants approaching the resonant length for the worst‐case uniform incident electric field along the screws’ length. The data may inform risk‐benefit assessments for imaging patients with orthopedic implants at the new clinical field strength of 7 Tesla.
Current Management and Future Directions for Pulmonary Arterial Hypertension Associated with Congenital Heart Disease
Mahmoud, Ahmed , Abbas, Mohammed Tiseer , Kamel, Moaz, Farina, Juan M. , Pereyra, Milagros , Scalia, Isabel G. , Barry, Timothy , Marcotte, François , Scott, Robert L. , Majdalany, David , Arsanjani, Reza , Kamel, Moaz A, Majdalany, David S , Arsanjani, Reza , Farina, Juan M , Pereyra, Milagros , Mahmoud, Ahmed K , Scalia, Isabel G , Abbas, Mohammed Tiseer , Chao, Chieh‐Ju

Journal of Personalized Medicine | December 20, 2023 | Volume: 14 | Issue: 1 | Pages: 5

10.3390/jpm14010005 | PMID 38276220 Get It

Current management of patients with congenital heart disease has increased their survival into adulthood. This is accompanied by potential cardiac complications, including pulmonary hypertension associated with congenital heart disease (PAH-CHD). PAH-CHD constitutes a challenging subgroup of pulmonary hypertension and requires expert management to improve quality of life and prognosis. Novel agents have shown a significant improvement in morbidity and mortality in patients with pulmonary arterial hypertension. However, the long-term effects of these medications on PAH-CHD patients remain somewhat uncertain, necessitating treatment plans largely founded on the clinical experience of the healthcare providers. The aim of this review is to summarize the current evidence and future perspectives regarding treatment strategies for PAH-CHD to help better guide management of this complex disease.
A Nationwide Network of Health AI Assurance Laboratories
Saria, Suchi , Pencina, Michael , Tazbaz, Troy, Tripathi, Micky, Hildahl, Hailey, Anderson, Brian, Shah, Nigam H. , Halamka, John , Callahan, Alison

JAMA | December 20, 2023 | Volume: 331 | Issue: 3 | Pages: 245

10.1001/jama.2023.26930 | PMID 38117493 Get It

Importance Given the importance of rigorous development and evaluation standards needed of artificial intelligence (AI) models used in health care, nationwide accepted procedures to provide assurance that the use of AI is fair, appropriate, valid, effective, and safe are urgently needed. Observations While there are several efforts to develop standards and best practices to evaluate AI, there is a gap between having such guidance and the application of such guidance to both existing and new AI models being developed. As of now, there is no publicly available, nationwide mechanism that enables objective evaluation and ongoing assessment of the consequences of using health AI models in clinical care settings. Conclusion and Relevance The need to create a public-private partnership to support a nationwide health AI assurance labs network is outlined here. In this network, community best practices could be applied for testing health AI models to produce reports on their performance that can be widely shared for managing the lifecycle of AI models over time and across populations and sites where these models are deployed.
The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge
Shalom, Eve , Kim, Harrison , Heijden, Rianne A. van der , Ahmed, Zaki , Patel, Reyna, DiCarlo, Julie C. , Yankeelov, Thomas E. , Stokes, Ashley M. , Grech‐Sollars, Matthew , Sahoo, Prativa , Verma, Sanjay Kumar , Rathore, Divya, Kazerouni, Anum S. , LoCastro, Eve , Paudyal, Ramesh , Wolansky, Ivan A. , Shukla‐Dave, Amita , Schouten, Pepijn, Gurney‐Champion, Oliver J. , Macíček, Ondřej , Vitouš, Jiří , Das, Ayesha , Mikheev, Artem , Rusinek, Henry , Cristinacce, Penny L. Hubbard , Little, Ross A. , Cheung, Susan , O’Connor, James P.B. , Moloney, Brendan, Bobholz, Samuel , Duenweg, Savannah , Laue, Hendrik , Sung, Kyunghyun , Nabavizadeh, Ali , Rad, Hamidreza Saligheh , Hu, Leland , Kazerooni, Anahita Fathi , Shalom, Eve S , van der Heijden, Rianne A , Hormuth, David A , DiCarlo, Julie C , Yankeelov, Thomas E , Dortch, Richard D , Grech-Sollars, Matthew , Kazerouni, Anum S , Partridge, Savannah C , LoCastro, Eve , Wolansky, Ivan A , Jiřík, Radovan , Macíček, Ondřej , Bartoš, Michal , Vitouš, Jiří , Das, Ayesha Bharadwaj , Kim, S Gene , Rusinek, Henry , Berks, Michael , Hubbard Cristinacce, Penny L , O'Connor, James P B , Parker, Geoff J M , LaViolette, Peter S , Bobholz, Samuel , Duenweg, Savannah , Virostko, John , Sung, Kyunghyun , Saligheh Rad, Hamidreza , Sourbron, Steven , Bell, Laura C , Fathi Kazerooni, Anahita , Paudyal, Ramesh , Shukla-Dave, Amita , Sisco, Nicholas J. , Inglese, Marianna , Toschi, Nicola , Singh, Anup K. , Schouten, Pepijn, Bokacheva, Louisa , Bell, Laura C.

Magnetic Resonance in Medicine | December 20, 2023 | Volume: 91 | Issue: 5 | Pages: 1803-1821

10.1002/mrm.29909 | PMID 38115695 Get It

AbstractPurpose has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.MethodsA framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.ResultsAcross the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.ConclusionsThis study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.