Abstract The cyclooxygenase (COX)-2 enzyme appears to be an important target for cancer chemoprevention. Given the recent emergence of potentially serious cardiovascular toxicity associated with selective COX-2 inhibitors, nonsteroidal antiinflammatory drugs (NSAIDs), which inhibit both COX-1 and COX-2, have received renewed attention as candidate chemoprevention agents. Sulindac has shown consistent chemopreventive potential in preclinical studies as well as in a limited number of clinical trials reported to date. For the current pharmacokinetic study, sulindac capsules were prepared to facilitate ample agent supplies for future intervention studies. Encapsulation of the parent compound (sulindac sulfoxide) can be readily accomplished, but the effects of alternate formulations on bioavailability have not been rigorously examined. In the present single-dose, two-period crossover trial, we conducted pharmacokinetic analyses of sulindac in capsule (test) versus tablet (reference) formulations. Overall, bioavailability appeared to be higher for the capsule compared with the tablet formulation based on test-to-reference pharmacokinetic variable ratios for the parent compound alone. However, additional analyses based on the sulfide and sulfone metabolites of sulindac with the same pharmacokinetic variables indicated similar chemopreventive exposures between the capsule and tablet formulations. These data support the use of sulindac capsules, which can be readily prepared with matching placebos, in future blinded chemoprevention trials. (Cancer Epidemiol Biomarkers Prev 2008;17(3):674–9)
Noncathartic CT Colonography with Stool Tagging: Performance With and Without Electronic Stool Subtraction
Abstract A policy of supportive treatment is frequently adopted for patients with metastatic disease to the adrenal glands. This study reports an experience with adrenalectomy for adrenal metastasis. Between 1983 and 1993, adrenalectomy was performed in 52 patients for metastasis to the adrenal glands. Survival was calculated by the Kaplan- Meier method and compared with the log rank test. Primary tumour sites included kidney (n = 15), lung (n = 11), colon (n = 7), unknown (n = 5), stomach (n = 3), melanoma (n = 3) and other (n = 8). Adenocarcinoma (69 per cent) was the most common histological cell type. Thirty-two patients were asymptomatic on initial evaluation. Symptomatic adrenal pain relief was achieved in 11 of 13 patients. Overall survival rates were 73 per cent at 1 year and 40 per cent at 2 years. Patients with potentially curative resection had better survival than those who had a palliative procedure. Patients with adrenal metastases due to adenocarcinoma had improved survival compared with that in those with other histological cell types. Although long-term survival is generally poor, highly selected patients with adrenal metastasis (symptomatic disease or adenocarcinoma) may benefit from surgical resection.
The epidemiology of microscopic colitis: a population based study in Olmsted County, Minnesota
Objective: Although the epidemiology of microscopic colitis has been described in Europe, no such data exist from North America. We studied the incidence, prevalence and temporal trends of microscopic colitis in a geographically defined US population. Design and setting: In this population based cohort study, residents of Olmsted County, Minnesota, with a new diagnosis of microscopic colitis, and all who had colon biopsies for evaluation of diarrhoea, between 1 January 1985 and 31 December 2001 were identified. Biopsies were reviewed for confirmation (cases) and to identify missed cases (diarrhoea biopsies). Main outcome measures: Incidence rates, age and sex adjusted to the 2000 US white population. Poisson regression assessed the association of calendar period, age and sex with incidence. Results: We identified 130 incident cases for an overall rate of 8.6 cases per 100 000 person-years. There was a significant secular trend, with incidence increasing from 1.1 per 100 000 early in the study to 19.6 per 100 000 by the end (p<0.001). Rates increased with age (p<0.001). By subtype, the incidence was 3.1 per 100 000 for collagenous colitis and 5.5 per 100 000 for lymphocytic colitis. Collagenous colitis was associated with female sex (p<0.001) but lymphocytic colitis was not. Prevalence (per 100 000 persons) on 31 December 2001 was 103.0 (39.3 for collagenous colitis and 63.7 for lymphocytic colitis). Conclusions: The incidence of microscopic colitis has increased significantly over time, and by the end of the study, the incidence and prevalence were significantly higher than reported previously. Microscopic colitis is associated with older age, and collagenous colitis is associated with female sex.
Verification of Antimicrobial Susceptibility Testing of
Mycobacterium tuberculosis
Comparison of Specimen Processing and Nucleic Acid Extraction by the Swab Extraction Tube System versus the MagNA Pure LC System for Laboratory Diagnosis of Herpes Simplex Virus Infections by LightCycler PCR
ABSTRACT A total of 563 specimens (234 dermal and 329 genital swabs) from patients suspected of having herpes simplex virus (HSV) infections were processed using two different extraction methods (the MagNA Pure LC system and the swab extraction tube system [SETS]); HSV DNA was amplified by LightCycler PCR. HSV DNA was detected in 157 of 563 specimens (27.9%) processed by the MagNA Pure LC system and in 179 of 563 specimens (31.8%) processed by SETS ( P < 0.0001). There was no specimen processed by the MagNA Pure LC extraction method that was positive only for HSV DNA. Of 157 specimens positive by both methods, HSV DNA copy levels were higher (using cycle crossover points [cycle threshold { C T }]) with SETS (mean C T , 25.9 cycles) than with the MagNA Pure LC system (mean C T , 32.0 cycles) ( P < 0.0001). The time to process 32 samples was longer with the MagNA Pure LC extraction system (90 min) than with SETS (35 min). HSV DNA extraction using SETS is faster, less expensive, and more sensitive than the MagNA Pure LC system and could replace the latter for the laboratory diagnosis of HSV infections using LightCycler PCR.
Evaluation of the COBAS TaqMan HCV Test with Automated Sample Processing Using the MagNA Pure LC Instrument
ABSTRACT The COBAS TaqMan HCV Test (TaqMan HCV; Roche Molecular Systems Inc., Branchburg, N.J.) for hepatitis C virus (HCV) performed on the COBAS TaqMan 48 Analyzer (Roche Molecular Systems) currently relies on a manual sample processing method. Implementation of an automated sample processing method would facilitate the clinical use of this test. In this study, we evaluated the performance characteristics of TaqMan HCV following automated sample processing by the MagNA Pure LC instrument (MP; Roche Applied Science, Indianapolis, Ind.). The analytical sensitivity of TaqMan HCV following sample processing by MP was 8.1 IU/ml (95% confidence interval, 6.1 to 15.2). The assay showed good linearity ( R 2 = 0.99) across a wide range of HCV RNA levels (25 to 5 × 10 6 IU/ml), with coefficients of variation ranging from 10% to 46%. Among 83 clinical specimens, the sensitivity and specificity of TaqMan HCV were 100% and 95%, respectively, when compared to the COBAS AMPLICOR hepatitis C virus test, version 2.0 (COBAS AMPLICOR; Roche Molecular Systems), with TaqMan HCV detecting two more HCV RNA-positive specimens than COBAS AMPLICOR. Both specimens were confirmed to be HCV RNA positive by the VERSANT HCV RNA qualitative test (Bayer HealthCare LLC, Tarrytown, N.Y.). There was also strong correlation ( R 2 = 0.95) and good agreement between the results from TaqMan HCV and the VERSANT HCV RNA 3.0 assay (bDNA) (Bayer HealthCare LLC) among a group of 93 clinical specimens. The MP is a versatile, labor-saving sample processing platform suitable for reliable performance of TaqMan HCV.
Comparison of the Roche LightCycler
vanA
/
vanB
Detection Assay and Culture for Detection of Vancomycin-Resistant Enterococci from Perianal Swabs
ABSTRACT We compared the performance characteristics of a real-time PCR method, the LightCycler vanA / vanB detection assay (Roche Diagnostics Corporation, Indianapolis, Ind.) to that of Enterococcosel agar (BBL, Sparks, Md.) for direct detection of vancomycin-resistant enterococci (VRE) from 894 perianal stool swabs. For 421 of 894 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing vancomycin at 6 μg/ml; for the remaining 473 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing 8 μg/ml vancomycin. The LightCycler method produced considerably more positive results than either the Enterococcosel plate containing vancomycin at 6 μg/ml ( n = 25 versus n = 11; sensitivity, 100%; specificity, 97%; positive predictive value [PPV], 42%; negative predictive value [NPV], 100%) or the Enterococcosel plate containing vancomycin at 8 μg/ml ( n = 31 versus n = 10; sensitivity, 100%; specificity, 95%; PPV, 32%; NPV, 100%). When possible, additional testing, including culture, LightCycler PCR, and/or a conventional PCR method (PCR-restriction fragment length polymorphism assay), were performed on either the original specimens or original cultures or subsequent specimens for cases in which the original specimen was positive by LightCycler PCR but the Enterococcosel plate was negative. This additional testing demonstrated positive results for 7 of 14 (50%) evaluable discordant specimens which initially tested as LightCycler PCR positive but culture negative using the Enterococcosel plate containing vancomycin at 6 μg/ml and 12 of 17 (71%) evaluable discordant specimens which initially tested as LightCycler positive but culture negative using the Enterococcosel plate containing vancomycin at (8 μg/ml). These results demonstrate that the LightCycler VRE detection assay is considerably more sensitive than the standard culture method for detecting VRE directly from perianal swab specimens. The LightCycler assay also provides results much faster than culture (∼3.5 versus ≥72 h). The use of this test could have important implications for the effective control and prevention of nosocomial outbreaks of VRE.