Investigation of scan path optimization in improving proton pencil beam scanning continuous delivery
Liu, Chunbo , Beltran, Chris , Park, Chunjoo, Yaddanapudi, Sridhar , Tan, Jun , Furutani, Keith M. , Liang, Xiaoying , Tan, Jun , Shen, Jiajian , Furutani, Keith M , Liang, Xiaoying , Beltran, Chris J , Yaddanapudi, Sridhar , Shen, Jiajian , Lu, Bo, Tan, Jun

Physics in Medicine & Biology | September 13, 2023 | Volume: 68 | Issue: 19 | Pages: 195023

10.1088/1361-6560/acf98e Get It

Abstract Objective . To investigate the impact of scan path optimization on the dose accuracy and beam delivery time (BDT) of proton pencil beam scanning in the dose-driven continuous scanning (DDCS). Approach . A diverse set of six clinical plans, representing various spot patterns and treatment sites, was used to evaluate the effectiveness of scan time optimization and scan length optimization. The DDCS dose discrepancy and BDT with optimized scan paths was compared to the default serpentine scan path. Main results . Both scan time optimization and scan path optimization were able to reduce the DDCS dose discrepancy compared to the default serpentine scan path. All plans, except for the layer repainting lung plan, achieved a 2%/2 mm gamma pass rate of over 99% and less than 1% PTV DVH root mean square error (RMSE) through scan path optimization. In the case of the layer repainting lung plan, when compared to the default serpentine scan path, the 2%/2 mm gamma pass rate showed improvements from 91.3% to 93.1% and 95.8%, while the PTV DVH RMSE decreased from 2.1% to 1.7% and 1.1% for scan time optimization and scan length optimization, respectively. Although scan time optimization resulted in shorter total scan times for all plans compared to the default scan path and scan length optimization tended to have longer total scan times. However, due to the short total scan times and their minimal contribution to the total BDT, the impact of scan path optimization on the total BDT was practically negligible. Significance . Both scan time optimization and scan length optimization proved to be effective in minimizing DDCS dose discrepancy. No definitive winner can be determined between these two optimization approaches. Both scan time and scan length optimization had minimal effect on the total BDT.
Technical note: Delivery benefit and dosimetric implication of synchrotron‐based proton pencil beam scanning using continuous scanning mode
Beltran, Chris , Liu, Chunbo , Shen, Jiajian , Shen, Jiajian , Beltran, Chris J , Liang, Xiaoying , Li, Heng , Furutani, Keith M.

Medical Physics | April 28, 2023 | Volume: 50 | Issue: 8 | Pages: 5252-5261

10.1002/mp.16434 Get It

AbstractBackgroundDiscrete spot scanning (DSS) is the commonly used method for proton pencil beam scanning (PBS). There is lack of data on the dose‐driven continuous scanning (DDCS).PurposeTo investigate delivery benefits and dosimetric implications of DDCS versus DSS for PBS systems.MethodsThe irradiation duty factor, beam delivery time (BDT), and dose deviation were simulated for eight treatment plans in prostate, head and neck, liver, and lung, with both conventional fractionation and hypofractionation schemes. DDCS results were compared with those of DSS.ResultsThe DDCS irradiation duty factor (range, 11%–41%) was appreciably improved compared to DSS delivery (range, 4%–14%), within which, hypofractionation schemes had greater improvement than conventional fractionation. With decreasing stop ratio constraints, the DDCS BDT reduction was greater, but dose deviation also increased. With stop ratio constraints of 2, 1, 0.5, and 0, DDCS BDT reduction reached to 6%, 10%, 12%, and 15%, respectively, and dose deviation reached to 0.6%, 1.7%, 3.0%, and 5.2% root mean square error in PTV DVH, respectively. The 3%/2‐mm gamma passing rate was greater than 99% with stop ratio constraints of 2 and 1, and greater than 95% with a stop ratio of 0.5. When the stop ratio constraint was removed, five of the eight treatment plans had a 3%/2‐mm gamma passing rate greater than 95%, and the other three plans had a 3%/2‐mm gamma passing rate between 90% and 95%.ConclusionsThe irradiation duty factor was considerably improved with DDCS. Smaller stop ratio constraints led to shorter BDTs, but with the cost of larger dose deviations. Our finding suggested that a stop ratio of 1 constraint seems to yield acceptable DDCS dose deviation.
Technical note: Comprehensive evaluations of gantry and couch rotation isocentricities for implementing proton stereotactic radiosurgery
Shen, Jiajian , Robertson, Daniel , Shipulin, K. N., Stoker, Joshua B., Ashman, Jonathan B. , Lara, Pedro, Keole, Sameer R., Wong, William W. , Vora, Sujay A., Robertson, Daniel G, Shipulin, Konstantin, Stoker, Joshua, Wong, William, Shen, Jiajian , Bues, Martin , Liu, Wei

Medical Physics | March 24, 2023 | Volume: 50 | Issue: 6 | Pages: 3359-3367

10.1002/mp.16382 Get It

AbstractBackgroundMechanical accuracy should be verified before implementing a proton stereotactic radiosurgery (SRS) program. Linear accelerator (Linac)‐based SRS systems often use electronic portal imaging devices (EPIDs) to verify beam isocentricity. Because proton therapy systems do not have EPID, beam isocentricity tests of proton SRS may still rely on films, which are not efficient.PurposeTo validate that our proton SRS system meets mechanical precision requirements and to present an efficient method to evaluate the couch and gantry's rotational isocentricity for our proton SRS system.MethodsA dedicated applicator to hold brass aperture for proton SRS system was designed. The mechanical precision of the system was tested using a metal ball and film for 11 combinations of gantry and couch angles. A more efficient quality assurance (QA) procedure was developed, which used a scintillator device to replace the film. The couch rotational isocentricity tests were performed using orthogonal kV x‐rays with the couch rotated isocentrically to five positions (0°, 315°, 270°, 225°, and 180°). At each couch position, the distance between the metal ball in kV images and the imaging isocenter was measured. The gantry isocentricity tests were performed using a cone‐shaped scintillator and proton beams at five gantry angles (0°, 45°, 90°, 135°, and 180°), and the isocenter position and the distance of each beam path to the isocenter were obtained. Daily QA procedure was performed for 1 month to test the robustness and reproducibility of the procedure.ResultsThe gantry and couch rotational isocentricity exhibited sub‐mm precision, with most measurements within ±0.5 mm. The 1‐month QA results showed that the procedure was robust and highly reproducible to within ±0.2 mm. The gantry isocentricity test using the cone‐shaped scintillator was accurate and sensitive to variations of ±0.2 mm. The QA procedure was efficient enough to be completed within 30 min. The 1‐month isocentricity position variations were within 0.5 mm, which demonstrating that the overall proton SRS system was stable and precise.ConclusionThe proton SRS Winston–Lutz QA procedure using a cone‐shaped scintillator was efficient and robust. We were able to verify radiation delivery could be performed with sub‐mm mechanical precision.
Technical note: Investigation of dose and LETd effect to rectum and bladder by using non‐straight laterals in prostate cancer receiving proton therapy
Yang, Yunze, Rwigema, Jean‐Claude M. , Vargas, Carlos , Yu, Nathan Y. , Keole, Sameer R., Wong, William W. , Shen, Jiajian , Schild, Steven E. , Shen, Jiajian , Bues, Martin , Liu, Wei

Medical Physics | October 8, 2022 | Volume: 49 | Issue: 12 | Pages: 7428-7437

10.1002/mp.16008 Get It

AbstractBackgroundParallel‐opposed lateral beams are the conventional beam arrangements in proton therapy for prostate cancer. However, when considering linear energy transfer (LET) and RBE effects, alternative beam arrangements should be investigated.PurposeTo investigate the dose and dose averaged LET (LETd) impact of using new beam arrangements rotating beams 5°–15° posteriorly to the laterals in prostate cancer treated with pencil‐beam‐scanning (PBS) proton therapy.MethodsTwenty patients with localized prostate cancer were included in this study. Four proton treatment plans for each patient were generated utilizing 0°, 5°, 10°, and 15° posterior oblique beam pairs relative to parallel‐opposed lateral beams. Dose‐volume histograms (DVHs) from posterior oblique beams were analyzed. Dose‐LETd‐volume histogram (DLVH) was employed to study the difference in dose and LETd with each beam arrangement. DLVH indices, , defined as the cumulative absolute volume that has a dose of at least d (Gy[RBE]) and a LETd of at least l (keV/µm), were calculated for both the rectum and bladder to the whole group of patients and two‐sub groups with and without hydrogel spacer. These metrics were tested using Wilcoxon signed‐rank test.ResultsRotating beam angles from laterals to slightly posterior by 5°–15° reduced high LETd volumes while it increased the dose volume in the rectum and increased LETd in bladders. Beam angles rotated five degrees posteriorly from laterals (i.e., gantry in 95° and 265°) are proposed since they achieved the optimal balance of better LETd sparing and minimal dose increase in the rectum. A reduction of V(50 Gy[RBE], 2.6 keV/µm) from 7.41 to 3.96 cc (p < 0.01), and a slight increase of V(50 Gy[RBE], 0 keV/µm) from 20.1 to 21.6 cc (p < 0.01) were observed for the group without hydrogel spacer. The LETd sparing was less effective for the group with hydrogel spacer, which achieved the reduction of V(50 Gy[RBE], 2.6 keV/µm) from 4.28 to 2.10 cc (p < 0.01).ConclusionsPosterior oblique angle plans improved LETd sparing of the rectum while sacrificing LETd sparing in the bladder in the treatment of prostate cancer with PBS. Beam angle modification from laterals to slightly posterior may be a strategy to redistribute LETd and perhaps reduce rectal toxicity risks in prostate cancer patients treated with PBS. However, the effect is reduced for patients with hydrogel spacer.
Investigation of beam delivery time for synchrotron-based proton pencil beam scanning system with novel scanning mode
Liang, Xiaoying , Liu, Chunbo , Shen, Jiajian , Bues, Martin , Dougherty, Jingjing M. , Parisi, Alessio , Shrestha, Deepak K. , Yaddanpudi, Sridhar, Beltran, Chris , Yaddanapudi, Sridhar , Furutani, Keith M. , Shen, Jiajian , Bues, Martin , Dougherty, Jingjing M , Parisi, Alessio , Beltran, Chris J , Liang, Xiaoying , Yaddanapudi, Sridhar , Li, Heng

Physics in Medicine & Biology | July 25, 2022 | Volume: 67 | Issue: 17 | Pages: 175001

10.1088/1361-6560/ac8410 Get It

Abstract Objective. To investigate synchrotron-based proton pencil beam scanning (PBS) beam delivery time (BDT) using novel continuous scanning mode. Approach. A BDT calculation model was developed for the Hitachi particle therapy system. The model was validated against the measured BDT of 36 representative clinical proton PBS plans with discrete spot scanning (DSS) in the current Hitachi proton therapy system. BDTs were calculated with the next generation using Mayo Clinic Florida system operating parameters for conventional DSS, and novel dose driven continuous scanning (DDCS). BDTs of DDCS with and without Break Spots were investigated. Main results. For DDCS without Break Spots, the use of Stop Ratio to control the transit dose largely reduced the beam intensity and consequently, severely prolonged the BDT. DDCS with Break Spots was able to maintain a sufficiently high beam intensity while controlling transit dose. In DDCS with Break Spots, tradeoffs were made between beam intensity and number of Break Spots. Therefore, BDT decreased with increased beam intensity but reached a plateau for beam intensity larger than 10 MU s −1 . Averaging over all clinical plans, BDT was reduced by 10% for DDCS with Break Spots compared to DSS. Significance. DDCS with Break Spots reduced BDT. DDCS has the potential to further reduce BDT under the ideal scenario which requests both stable beam intensity extraction and accurately modelling the transit dose. Further investigation is warranted.
Technical note: Evaluation and second check of a commercial Monte Carlo dose engine for small‐field apertures in pencil beam scanning proton therapy
Holmes, Jason , Shen, Jiajian , Shan, Jie , Patrick, Christopher L., Wong, William W. , Foote, Robert L. , Patel, Samir H. , Bues, Martin , Shen, Jiajian , Holmes, Jason M , Liu, Wei

Medical Physics | March 19, 2022 | Volume: 49 | Issue: 5 | Pages: 3497-3506

10.1002/mp.15604 Get It

Abstract Purpose To evaluate the accuracy of the RayStation Monte Carlo dose engine (RayStation MC) in modeling small‐field block apertures in proton pencil beam scanning. Furthermore, we evaluate the suitability of MCsquare as a second check for RayStation MC. Methods We have enhanced MCsquare to model block apertures. To test the accuracy of both RayStation MC and the newly enhanced MCsquare, we compare the dose predictions of each to in‐water dose measurements obtained using diode detectors and radiochromic film. Nine brass apertures with openings of 1, 2, 3, 4, and 5 cm and either 2 cm or 4 cm thickness were used in the irradiation of a water phantom. Two measurement setups were used, one with a range shifter and 119.7 MeV proton beam energy and the other with no range shifter and 147 MeV proton beam energy. To further test the validity of RayStation MC and MCsquare in modeling block apertures and to evaluate MCsquare as a second check tool, 10 small‐field (average target volume 8.3 cm 3 ) patient treatment plans were calculated by each dose engine followed by a statistical comparison. Results Comparing to the absolute dose measurements in water, RayStation MC differed by 1.2% ± 1.0% while MCsquare differed by −1.8% ± 3.7% in the plateau region of a pristine Bragg peak. Compared to the in‐water film measurements, RayStation MC and MCsquare both performed well with an average 2D‐3D gamma passing rate of 99.4% and 99.7% (3%/3 mm), respectively. A t ‐test comparing the agreement with the film measurements between RayStation MC and MCsquare suggested that the relative spatial dose distributions calculated by MCsquare and RayStation MC were statistically indistinguishable. Directly comparing the dose calculations between MCsquare and RayStation MC over 10 patients resulted in an average 3D‐3D gamma passing rates of 98.5% (3%/3 mm) and 94.1% (2%/2 mm), respectively. Conclusion The validity of RayStation MC algorithm for use with patient‐specific apertures has been expanded to include small apertures. MCsquare has been enhanced to model apertures and was found to be an adequate second check of RayStation MC in this scenario.
Building a precise machine-specific time structure of the spot and energy delivery model for a cyclotron-based proton therapy system
Zhao, Lewei , Zheng, Weili , Shen, Jiajian , Lee, Andrew , Yan, Di , Deraniyagala, Rohan, Stevens, Craig , Tang, Shikui, Ding, Xuanfeng , Shen, Jiajian , Liu, Gang , Li, Xiaoqiang

Physics in Medicine & Biology | December 14, 2021 | Volume: 67 | Issue: 1 | Pages: 01NT01

10.1088/1361-6560/ac431c Get It

Abstract Objective . We proposed an experimental approach to build a precise machine-specific beam delivery time (BDT) prediction and delivery sequence model for standard, volumetric, and layer repainting delivery based on a cyclotron accelerator system. Approach . Test fields and clinical treatment plans’ log files were used to experimentally derive three main beam delivery parameters that impacted BDT: energy layer switching time (ELST), spot switching time, and spot drill time. This derived machine-specific model includes standard, volumetric, and layer repainting delivery sequences. A total of 103 clinical treatment fields were used to validate the model. Main results . The study found that ELST is not stochastic in this specific machine. Instead, it is actually the data transmission time or energy selection time, whichever takes longer. The validation showed that the accuracy of each component of the BDT matches well between machine log files and the model’s prediction. The average total BDT was about (−0.74 ± 3.33)% difference compared to the actual treatment log files, which is improved from the current commercial proton therapy system’s prediction (67.22%±26.19%). Significance . An accurate BDT prediction and delivery sequence model was established for an cyclotron-based proton therapy system IBA ProteusPLUS ® . Most institutions could adopt this method to build a machine-specific model for their own proton system.
Technical Note: Long‐term monitoring of diode sensitivity degradation induced by proton irradiation
Younkin, James E. , Robertson, Daniel , Hu, Yanle , Morales, Danairis Hernandez, Shen, Jiajian , Ding, Xiaoning, Robertson, Daniel G, Bues, Martin , Shen, Jiajian , Liu, Wei

Medical Physics | October 7, 2021 | Volume: 48 | Issue: 11 | Pages: 6634-6641

10.1002/mp.15265 Get It

AbstractPurposeTo measure diode sensitivity degradation (DSD) induced by cumulative proton dose delivered to a commercial daily quality assurance (QA) device.MethodsAt our institution, six Daily QA 3 (DQA3, Sun Nuclear Corporation, Melbourne, FL, USA) devices have been used for daily proton pencil beam scanning QA in four proton gantry rooms over a span of 4 years. DQA3 diode counts were cross‐calibrated using a homogenous field with a known dose of 1 Gy. The DSD rate (ΔR%/100 Gy) was calculated using linear regression on time‐series plots of diode counts and an estimate of cumulative dose per year based on the cross‐calibration. The effect of DSD on daily QA spot position measurements was quantified by converting DSD to baseline spot position shift.ResultsThe average dose delivered to the four inner DQA3 diodes was 104 ± 5 Gy/year, and the rate of DSD was ‐5.1% ± 1.0/100 Gy with the exception of one DQA3 device that had a significantly higher rate of DSD (–12%/100 Gy). The R2s of the linear fit to time‐series plots were between 0.92 and 0.98. The DSD rates were not constant but decreases with accumulated doses. The four center diodes, which received 40% of the cumulative dose received by inner diodes, had a DSD rate of –7.2% ± 0.9/100 Gy. For our daily QA program, 1 year of DSD was equivalent to a 0.2 mm shift in spot position.ConclusionsThe DSD rate of DQA3 diodes determined by long‐term proton daily QA data was about –5%/100 Gy, which is more than 10 times greater than the reported DSD rate from photon irradiation. DQA3 diodes may be used for daily proton QA programs, provided that they are recalibrated at an appropriate frequency that should be determined specifically for different daily QA programs.
Technical Note: Clinical modeling and validation of breast tissue expander metallic ports in a commercial treatment planning system for proton therapy
Kang, Yixiu, Shen, Jiajian , Hu, Yanle , Ding, Xiaoning, Bues, Martin , Shen, Jiajian , Liu, Wei

Medical Physics | September 14, 2021 | Volume: 48 | Issue: 11 | Pages: 7512-7525

10.1002/mp.15225 Get It

AbstractPurposeTo validate breast tissue expander metallic port (MP) models in a commercial treatment planning system (TPS) in proton pencil beam scanning (PBS) treatments for breast cancer patients with breast tissue expanders.Methods and materialsThree types of MPs taken out of a Mentor CPX4, a Natrelle 133, and a PMT Integra breast tissue expanders and a 650 cc saline filled Mentor CPX4 expander were placed on top of acrylic slabs, and scanned using a Siemens Somatom Definition AS Open RT CT scanner. Structure templates for each of the MPs were designed within Eclipse TPS. The CT numbers for the metallic parts were overridden to reflect measured or calculated relative proton stopping powers (RPSPs). Mock targets were contoured in acrylic to represent postmastectomy chest‐wall radiation therapy (PMRT) targets. Plans with different beam incident angles were optimized using the Eclipse TPS to deliver uniform prescription dose to the target using Hitachi Probeat‐V PBS beams. Eclipse calculated doses and an in‐house Monte Carlo (MC) code calculated doses were compared to the measured Gafchromic EBT3 film doses in acrylic.ResultsTPS/MC and film dose comparison results showed that (1) 3%/2 mm/10% threshold Gamma pass rates were better than 90.8% in the acrylic target region for all plans; (2) comparing TPS and film doses for the individual beam plans in the MP dose shadow areas, the area with dose difference above 5% ([ΔA] 5%) ranged from 1.1 to 5.0 cm2, and the maximum dose difference ([ΔD] 0.01 cm2) ranged from 12.5% to 25.0%; (3) comparing MC and film doses for the individual beam plans in the MP dose shadow areas, the (ΔA) 5% varied from 1.1 to 2.9 cm2 and (ΔD) 0.01 cm2 varied from 8.5% to 24.2%; (4) for a plan composed of three individual beams treating through the Mentor CPX4 expander, the TPS (ΔA) 5% was less than 0.13 cm2, and the (ΔD) 0.01 cm2 was less than 6% in the MP dose shadow areas.ConclusionsIt is feasible to treat patients with tissue expanders using multiple PBS beams using a structure template with CT number overridden to represent the measured/calculated RPSP for MPs for PBS treatment planning. MC dose was more accurate than analytical dose in the areas with high dose gradient caused by the density heterogeneity of the breast tissue expander MPs.
Technical Note: Multiple energy extraction techniques for synchrotron‐based proton delivery systems may exacerbate motion interplay effects in lung cancer treatments
Younkin, James E. , Morales, Danairis Hernandez, Shen, Jiajian , Ding, Xiaoning, Stoker, J. , Yu, Nathan Y. , Daniels, T.B., Fatyga, M., Stoker, Joshua B., Daniels, Thomas B, Bues, Martin , Fatyga, Mirek, Schild, Steven E. , Shen, Jiajian , Sio, Terence T. , Liu, Wei

Medical Physics | June 26, 2021 | Volume: 48 | Issue: 9 | Pages: 4812-4823

10.1002/mp.15056 Get It

Abstract Purpose The multiple energy extraction (MEE) delivery technique for synchrotron‐based proton delivery systems reduces beam delivery time by decelerating the beam multiple times during one accelerator spill, but this might cause additional plan quality degradation due to intrafractional motion. We seek to determine whether MEE causes significantly different plan quality degradation compared to single energy extraction (SEE) for lung cancer treatments due to the interplay effect. Methods Ten lung cancer patients treated with IMPT at our institution were nonrandomly sampled based on a representative range of tumor motion amplitudes, tumor volumes, and respiratory periods. Dose‐volume histogram (DVH) indices from single‐fraction SEE and MEE four‐dimensional (4D) dynamic dose distributions were compared using the Wilcoxon signed‐rank test. Distributions of monitor units (MU) to breathing phases were investigated for features associated with plan quality degradation. SEE and MEE DVH indices were compared in fractionated deliveries of the worst‐case patient treatment scenario to evaluate the impact of fractionation. Results There were no clinically significant differences in target mean dose, target dose conformity, or dose to organs‐at‐risk between SEE and MEE in single‐fraction delivery. Three patients had significantly worse dose homogeneity with MEE compared to SEE (single‐fraction mean D 5% ‐D 95% increased by up to 9.6% of prescription dose), and plots of MU distribution to breathing phases showed synchronization patterns with MEE but not SEE. However, after 30 fractions the patient in the worst‐case scenario had clinically acceptable target dose homogeneity and coverage with MEE (mean D 5% –D 95% increased by 1% compared to SEE). Conclusions For some patients with breathing periods close to the mean spill duration, MEE resulted in significantly worse single‐fraction target dose homogeneity compared to SEE due to the interplay effect. However, this was mitigated by fractionation, and target dose homogeneity and coverage were clinically acceptable after 30 fractions with MEE.