Back to Authors

Tang, Shikui

Mayo Clinic

Department of Radiation Oncology Texas Center for Proton Therapy Irving Texas USA

Citations 2

Multi‐institutional survey of source modeling parameters for proton pencil beam scanning treatment planning system commissioning
Maradia, Vivek , Chang, Chih‐Wei , Kang, Minglei , Tang, Shikui, Wang, Peng , Freund, D, Zhao, Tianyu , Chang, Chang , Chen, Chin‐Cheng, Pankuch, Mark , Gao, Mingcheng , Yu, Francis T. S., Lin, Haibo , Li, Zuofeng , Regmi, Rajesh, Depuydt, Tom, Liu, Haoyang, Broekhoven, Bethany L., Mossahebi, Sina , Yi, Byong Yong, Paxton, Adam , Matsuura, Taeko , Vilches‐Freixas, Gloria , Kurucz, Samuel , Ding, Xuanfeng , Charyyev, Serdar , Lin, Liyong , Dong, Lei , Li, Heng , Schuemann, Jan , Shen, Jiajian , Taylor, Paige A. , Zhang, Yawei , Zhang, Hailei , Chen, Chin‐Cheng, Wong, Tony , Poels, Kenneth , Wang, Zishen , Lin, Yuting

Medical Physics | December 13, 2025 | Volume: 52 | Issue: 12 | Pages: No page available

10.1002/mp.70199 Get It

Abstract Background Standardizing beam modeling in the treatment planning system is challenging due to machine‐specific configuration variations. Because of the proton therapy system (PTS) complexity and continuous development, there is no vendor's representative (“golden”) beam data like in LINACs at this stage. Purpose The primary goal of this study is to create a PTS‐specific repository of source model parameters and beam commissioning data for scanning proton therapy treatment planning systems and establish a set of reference values with associated bands of variations for this data. Methods We conducted a survey of 31 PTSs at 27 proton therapy centers to gather beam commissioning source model parameters used in their treatment planning system, ensuring a diverse selection of PTSs from major vendors: Hitachi, IBA, Varian, and Mevion. For each proton therapy center, we collected (i) beam meterset calibration in protons per MU, (ii) in‐air spot size at isocenter in terms of standard deviation in x‐ (crossline, σ x ) and y‐ (inline, σ y ) directions, (iii) in‐air angular spread at isocenter in x‐direction (θ x ) and y‐direction (θ y ) and (iv) distal falloff. For each PTS, we plotted each parameter as a function of nominal energy and performed polynomial regression analysis with optimal model selection based on Akaike Information Criterion. We calculated intraclass correlation coefficients (ICC) to quantify inter‐PTS variability and generated uncertainty bands representing standard deviations across PTSs for each parameter. Additionally, we computed percentage deviations of each individual PTS from the overall multi‐vendor mean to identify systematic vendor‐specific patterns and outliers across the 31 total PTSs analyzed. Results Multi‐vendor beam parameter analysis across 31 PTSs revealed systematic vendor‐specific patterns in inter‐PTS consistency and energy dependencies. Beam meterset calibration demonstrated excellent inter‐PTS consistency across most vendors (ICC: Varian ProBeam ≈ 0, IBA Proteus ONE = 0.006, Mevion S250i with HYPERSCAN = 0.015), with IBA Proteus PLUS systems showing moderate variation (ICC = 0.156 for the dedicated nozzle, ICC = 0.248, for the universal nozzle). Spot size and angular spread variability were highly vendor‐dependent, ranging from excellent consistency in IBA Proteus ONE to substantial variation in IBA Proteus PLUS with the universal nozzle (angular spread ICC = 0.566). Distal falloff maintained excellent consistency across all vendors (ICC < 0.023), indicating reliable energy spread characteristics. Uncertainty band analysis revealed characteristic energy‐dependent patterns, with most systems showing larger uncertainties at lower energies for spot size and angular spread, while IBA Proteus PLUS with the universal nozzle exhibited the largest uncertainty bands overall. Percentage deviation analysis demonstrated vendor‐specific clustering patterns, with some systems showing systematic positive or negative deviations from the multi‐vendor mean. Conclusions The reference data provided in this work will help to cross‐check the beam model during treatment planning system commissioning. Furthermore, this information is useful for Monte Carlo applications and research, where beam characteristics are required to set up phase space parameters, thereby avoiding the need to model the entire PTS. Finally, the results of this study will have indispensable educational value by providing valuable insights into the characteristics and capabilities of different PTSs.
Building a precise machine-specific time structure of the spot and energy delivery model for a cyclotron-based proton therapy system
Zhao, Lewei , Zheng, Weili , Shen, Jiajian , Lee, Andrew , Yan, Di , Deraniyagala, Rohan, Stevens, Craig , Tang, Shikui, Ding, Xuanfeng , Shen, Jiajian , Liu, Gang , Li, Xiaoqiang

Physics in Medicine & Biology | December 14, 2021 | Volume: 67 | Issue: 1 | Pages: 01NT01

10.1088/1361-6560/ac431c Get It

Abstract Objective . We proposed an experimental approach to build a precise machine-specific beam delivery time (BDT) prediction and delivery sequence model for standard, volumetric, and layer repainting delivery based on a cyclotron accelerator system. Approach . Test fields and clinical treatment plans’ log files were used to experimentally derive three main beam delivery parameters that impacted BDT: energy layer switching time (ELST), spot switching time, and spot drill time. This derived machine-specific model includes standard, volumetric, and layer repainting delivery sequences. A total of 103 clinical treatment fields were used to validate the model. Main results . The study found that ELST is not stochastic in this specific machine. Instead, it is actually the data transmission time or energy selection time, whichever takes longer. The validation showed that the accuracy of each component of the BDT matches well between machine log files and the model’s prediction. The average total BDT was about (−0.74 ± 3.33)% difference compared to the actual treatment log files, which is improved from the current commercial proton therapy system’s prediction (67.22%±26.19%). Significance . An accurate BDT prediction and delivery sequence model was established for an cyclotron-based proton therapy system IBA ProteusPLUS ® . Most institutions could adopt this method to build a machine-specific model for their own proton system.