AbstractObjectiveThe aim of this study was to evaluate the feasibility and plan quality of spot‐scanning proton arc therapy (SPArc) using a synchrotron‐accelerator‐based proton therapy system compared to intensity‐modulated proton therapy (IMPT).ApproachFive representative disease sites, including head and neck, lung, liver, brain chordoma, and prostate cancers, were retrospectively selected. Both IMPT and SPArc plans are generated with the HITACHI ProBEAT PBS system's minimum MU constraints and physics beam model. The SPArc plans are generated with 2.5° sampling frequency. The static delivery time was simulated based on the previously published synchrotron delivery sequence model, and the dynamic delivery time was simulated using a proton arc gantry mechanical model integrated with the synchrotron delivery sequence. Both dosimetric plan quality and delivery efficiency are evaluated.Main resultsA superior plan quality is reached compared with the IMPT plans generated for the same disease site. However, a relatively prolonged static and dynamic delivery time post new challenge, as static time increased by 49.22% and dynamic time 59.10% on average.SignificanceThis study presents the first simulation results of delivering the SPArc plans using a synchrotron‐accelerated proton therapy system. The result shows its feasibility and limitations, which could guide future development.
Building a precise machine-specific time structure of the spot and energy delivery model for a cyclotron-based proton therapy system
Abstract Objective . We proposed an experimental approach to build a precise machine-specific beam delivery time (BDT) prediction and delivery sequence model for standard, volumetric, and layer repainting delivery based on a cyclotron accelerator system. Approach . Test fields and clinical treatment plans’ log files were used to experimentally derive three main beam delivery parameters that impacted BDT: energy layer switching time (ELST), spot switching time, and spot drill time. This derived machine-specific model includes standard, volumetric, and layer repainting delivery sequences. A total of 103 clinical treatment fields were used to validate the model. Main results . The study found that ELST is not stochastic in this specific machine. Instead, it is actually the data transmission time or energy selection time, whichever takes longer. The validation showed that the accuracy of each component of the BDT matches well between machine log files and the model’s prediction. The average total BDT was about (−0.74 ± 3.33)% difference compared to the actual treatment log files, which is improved from the current commercial proton therapy system’s prediction (67.22%±26.19%). Significance . An accurate BDT prediction and delivery sequence model was established for an cyclotron-based proton therapy system IBA ProteusPLUS ® . Most institutions could adopt this method to build a machine-specific model for their own proton system.