Abstract Background Standardizing beam modeling in the treatment planning system is challenging due to machine‐specific configuration variations. Because of the proton therapy system (PTS) complexity and continuous development, there is no vendor's representative (“golden”) beam data like in LINACs at this stage. Purpose The primary goal of this study is to create a PTS‐specific repository of source model parameters and beam commissioning data for scanning proton therapy treatment planning systems and establish a set of reference values with associated bands of variations for this data. Methods We conducted a survey of 31 PTSs at 27 proton therapy centers to gather beam commissioning source model parameters used in their treatment planning system, ensuring a diverse selection of PTSs from major vendors: Hitachi, IBA, Varian, and Mevion. For each proton therapy center, we collected (i) beam meterset calibration in protons per MU, (ii) in‐air spot size at isocenter in terms of standard deviation in x‐ (crossline, σ x ) and y‐ (inline, σ y ) directions, (iii) in‐air angular spread at isocenter in x‐direction (θ x ) and y‐direction (θ y ) and (iv) distal falloff. For each PTS, we plotted each parameter as a function of nominal energy and performed polynomial regression analysis with optimal model selection based on Akaike Information Criterion. We calculated intraclass correlation coefficients (ICC) to quantify inter‐PTS variability and generated uncertainty bands representing standard deviations across PTSs for each parameter. Additionally, we computed percentage deviations of each individual PTS from the overall multi‐vendor mean to identify systematic vendor‐specific patterns and outliers across the 31 total PTSs analyzed. Results Multi‐vendor beam parameter analysis across 31 PTSs revealed systematic vendor‐specific patterns in inter‐PTS consistency and energy dependencies. Beam meterset calibration demonstrated excellent inter‐PTS consistency across most vendors (ICC: Varian ProBeam ≈ 0, IBA Proteus ONE = 0.006, Mevion S250i with HYPERSCAN = 0.015), with IBA Proteus PLUS systems showing moderate variation (ICC = 0.156 for the dedicated nozzle, ICC = 0.248, for the universal nozzle). Spot size and angular spread variability were highly vendor‐dependent, ranging from excellent consistency in IBA Proteus ONE to substantial variation in IBA Proteus PLUS with the universal nozzle (angular spread ICC = 0.566). Distal falloff maintained excellent consistency across all vendors (ICC < 0.023), indicating reliable energy spread characteristics. Uncertainty band analysis revealed characteristic energy‐dependent patterns, with most systems showing larger uncertainties at lower energies for spot size and angular spread, while IBA Proteus PLUS with the universal nozzle exhibited the largest uncertainty bands overall. Percentage deviation analysis demonstrated vendor‐specific clustering patterns, with some systems showing systematic positive or negative deviations from the multi‐vendor mean. Conclusions The reference data provided in this work will help to cross‐check the beam model during treatment planning system commissioning. Furthermore, this information is useful for Monte Carlo applications and research, where beam characteristics are required to set up phase space parameters, thereby avoiding the need to model the entire PTS. Finally, the results of this study will have indispensable educational value by providing valuable insights into the characteristics and capabilities of different PTSs.
Technical note: Delivery benefit and dosimetric implication of synchrotron‐based proton pencil beam scanning using continuous scanning mode
AbstractBackgroundDiscrete spot scanning (DSS) is the commonly used method for proton pencil beam scanning (PBS). There is lack of data on the dose‐driven continuous scanning (DDCS).PurposeTo investigate delivery benefits and dosimetric implications of DDCS versus DSS for PBS systems.MethodsThe irradiation duty factor, beam delivery time (BDT), and dose deviation were simulated for eight treatment plans in prostate, head and neck, liver, and lung, with both conventional fractionation and hypofractionation schemes. DDCS results were compared with those of DSS.ResultsThe DDCS irradiation duty factor (range, 11%–41%) was appreciably improved compared to DSS delivery (range, 4%–14%), within which, hypofractionation schemes had greater improvement than conventional fractionation. With decreasing stop ratio constraints, the DDCS BDT reduction was greater, but dose deviation also increased. With stop ratio constraints of 2, 1, 0.5, and 0, DDCS BDT reduction reached to 6%, 10%, 12%, and 15%, respectively, and dose deviation reached to 0.6%, 1.7%, 3.0%, and 5.2% root mean square error in PTV DVH, respectively. The 3%/2‐mm gamma passing rate was greater than 99% with stop ratio constraints of 2 and 1, and greater than 95% with a stop ratio of 0.5. When the stop ratio constraint was removed, five of the eight treatment plans had a 3%/2‐mm gamma passing rate greater than 95%, and the other three plans had a 3%/2‐mm gamma passing rate between 90% and 95%.ConclusionsThe irradiation duty factor was considerably improved with DDCS. Smaller stop ratio constraints led to shorter BDTs, but with the cost of larger dose deviations. Our finding suggested that a stop ratio of 1 constraint seems to yield acceptable DDCS dose deviation.
Abstract Objective. To investigate synchrotron-based proton pencil beam scanning (PBS) beam delivery time (BDT) using novel continuous scanning mode. Approach. A BDT calculation model was developed for the Hitachi particle therapy system. The model was validated against the measured BDT of 36 representative clinical proton PBS plans with discrete spot scanning (DSS) in the current Hitachi proton therapy system. BDTs were calculated with the next generation using Mayo Clinic Florida system operating parameters for conventional DSS, and novel dose driven continuous scanning (DDCS). BDTs of DDCS with and without Break Spots were investigated. Main results. For DDCS without Break Spots, the use of Stop Ratio to control the transit dose largely reduced the beam intensity and consequently, severely prolonged the BDT. DDCS with Break Spots was able to maintain a sufficiently high beam intensity while controlling transit dose. In DDCS with Break Spots, tradeoffs were made between beam intensity and number of Break Spots. Therefore, BDT decreased with increased beam intensity but reached a plateau for beam intensity larger than 10 MU s −1 . Averaging over all clinical plans, BDT was reduced by 10% for DDCS with Break Spots compared to DSS. Significance. DDCS with Break Spots reduced BDT. DDCS has the potential to further reduce BDT under the ideal scenario which requests both stable beam intensity extraction and accurately modelling the transit dose. Further investigation is warranted.
Perturbation of water‐equivalent thickness as a surrogate for respiratory motion in proton therapy
Respiratory motion is traditionally assessed using tumor motion magnitude. In proton therapy, respiratory motion causes density variations along the beam path that result in uncertainties of proton range. This work has investigated the use of water‐equivalent thickness (WET) to quantitatively assess the effects of respiratory motion on calculated dose in passively scattered proton therapy (PSPT). A cohort of 29 locally advanced non‐small cell lung cancer patients treated with 87 PSPT treatment fields were selected for analysis. The variation in WET (ΔWET) along each field was calculated between exhale and inhale phases of the simulation four‐dimensional computed tomography. The change in calculated dose (ΔDose) between full‐inhale and full‐exhale phase was quantified for each field using dose differences, 3D gamma analysis, and differential area under the curve (ΔAUC) analysis. Pearson correlation coefficients were calculated between ΔDose and ΔWET. Three PSPT plans were redesigned using field angles to minimize variations in ΔWET and compared to the original plans. The median ΔWET over 87 treatment fields ranged from 1‐9 mm, while the ΔWET 95th percentile value ranged up to 42 mm. The ΔWET was significantly correlated to the ΔDose for all metrics analyzed. The patient plans that were redesigned using ΔWET analysis to select field angles were more robust to the effects of respiratory motion, as ΔAUC values were reduced by more than 60% in all three cases. The tumor motion magnitude alone does not capture the potential dosimetric error due to respiratory motion because the proton range is sensitive to the motion of all patient anatomy. The use of ΔWET has been demonstrated to identify situations where respiratory motion can impact the calculated dose. Angular analysis of ΔWET may be capable of designing radiotherapy plans that are more robust to the effects of respiratory motion.PACS number(s): 87.55.‐x
Evaluation of the systematic error in using 3D dose calculation in scanning beam proton therapy for lung cancer
The objective of this study was to evaluate and understand the systematic error between the planned three‐dimensional (3D) dose and the delivered dose to patient in scanning beam proton therapy for lung tumors. Single‐field and multifield optimized scanning beam proton therapy plans were generated for ten patients with stage II‐III lung cancer with a mix of tumor motion and size. 3D doses in CT datasets for different respiratory phases and the time‐weighted average CT, as well as the four‐dimensional (4D) doses were computed for both plans. The 3D and 4D dose differences for the targets and different organs at risk were compared using dose‐volume histogram (DVH) and voxel‐based techniques, and correlated with the extent of tumor motion. The gross tumor volume (GTV) dose was maintained in all 3D and 4D doses, using the internal GTV override technique. The DVH and voxel‐based techniques are highly correlated. The mean dose error and the standard deviation of dose error for all target volumes were both less than 1.5% for all but one patient. However, the point dose difference between the 3D and 4D doses was up to 6% for the GTV and greater than 10% for the clinical and planning target volumes. Changes in the 4D and 3D doses were not correlated with tumor motion. The planning technique (single‐field or multifield optimized) did not affect the observed systematic error. In conclusion, the dose error in 3D dose calculation varies from patient to patient and does not correlate with lung tumor motion. Therefore, patient‐specific evaluation of the 4D dose is important for scanning beam proton therapy for lung tumors.PACS number: 87.55.D